Lightning Efficient Counterpoise Configurations for Transmission Line Grounding

被引:3
|
作者
Grcev, Leonid [1 ]
Markovski, Blagoja [2 ]
Todorovski, Mirko [2 ]
机构
[1] Macedonian Acad Sci & Arts, Skopje 1000, North Macedonia
[2] Ss Cyril & Methodius Univ Skopje, Fac Elect Engn & Informat Technol, Skopje 1000, North Macedonia
关键词
Grounding; Lightning; Soil; Load flow analysis; Wires; Conductivity; Poles and towers; Transmission lines; lightning protection; ground-; ing; modeling; DEPENDENT SOIL MODELS; IMPULSE IMPEDANCE; EFFECTIVE LENGTH; WIRE;
D O I
10.1109/TPWRD.2022.3200579
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Different configurations of counterpoises are often used to reduce the resistance and impulse impedance of the transmission line grounding. However, there are no general rules for an actual design. This paper analyses the performance of several configurations of counterpoises under typical lightning current impulses. The basis is a parametric analysis derived from time responses of 11,386 test cases for each configuration with parameters in broad ranges computed using a rigorous electromagnetic model based on the method of moments. The contributions of the paper are: Simple formulas for the resistance, impulse impedance, and effective length of counterpoise configurations are derived from and verified by the simulation results; a configuration with an 8-leg counterpoise bent parallel to the line is proposed, which extends the effective length and is efficient in high resistivity soil; and the method does not depend on the different lightning current impulse waveform representations based on Heidler, CIGRE, and double-exponential formulas, since the results can be easily converted. A simple procedure is provided to compare the capabilities and limitations of counterpoise configurations. New formulas and procedures make up a general and straightforward method for analyzing the optimal design, considering the cost-effective and best protection against lightning.
引用
收藏
页码:877 / 888
页数:12
相关论文
共 50 条
  • [1] An optimized transmission line model of grounding electrodes under lightning currents
    YANG Lin
    WU GuangNing
    CAO XiaoBin
    [J]. Science China Technological Sciences, 2013, (02) : 335 - 341
  • [2] An optimized transmission line model of grounding electrodes under lightning currents
    Lin Yang
    GuangNing Wu
    XiaoBin Cao
    [J]. Science China Technological Sciences, 2013, 56 : 335 - 341
  • [3] An optimized transmission line model of grounding electrodes under lightning currents
    YANG Lin
    WU GuangNing
    CAO XiaoBin
    [J]. Science China(Technological Sciences), 2013, 56 (02) : 335 - 341
  • [4] An optimized transmission line model of grounding electrodes under lightning currents
    Yang Lin
    Wu GuangNing
    Cao XiaoBin
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2013, 56 (02) : 335 - 341
  • [5] Effects of transmission line tower grounding improvements on its lightning performance
    Diaz, Luis
    Grange, Francois
    Journet, Sebastien
    Dawalibi, Farid
    [J]. 2021 35TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) AND XVI INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (SIPDA), 2021,
  • [6] An Investigation of Direct Grounding System Effect on Modeling of Lightning and Tower in Transmission Line
    Nugroho, Agung
    Abouzeid, Omar
    Hermawan
    Syakur, Abdul
    Karnoto
    Facta, Mochammad
    [J]. 2018 5TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY, COMPUTER, AND ELECTRICAL ENGINEERING (ICITACEE), 2018, : 272 - 275
  • [7] A frequency dependent transmission line model for a counterpoise
    Mishra, Arbind Kumar
    Nagaoka, Naoto
    Ametani, Akhihiro
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2006, 1 (01) : 14 - 23
  • [8] Choosing configurations of transmission line tower grounding by back flashover probability value
    Kuklin, Dmitry
    [J]. FRONTIERS IN ENERGY, 2016, 10 (02) : 213 - 226
  • [9] Choosing configurations of transmission line tower grounding by back flashover probability value
    Dmitry KUKLIN
    [J]. Frontiers in Energy, 2016, 10 (02) : 213 - 226
  • [10] Choosing configurations of transmission line tower grounding by back flashover probability value
    Dmitry Kuklin