Photonics Scanning Pentaprism System for the Integrated Inspection of Large-Aperture Telescopes

被引:4
|
作者
An, Qichang [1 ,2 ]
Zhang, Hanfu [1 ,2 ,3 ]
Wang, Kun [1 ,2 ]
Liu, Xinyue [1 ,2 ]
Li, Hongwen [1 ,2 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
[2] Jilin Prov Key Lab Intelligent Wavefront Sensing &, Changchun 130033, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100039, Peoples R China
关键词
fiber-connection; spectrum calibration; assembling; integrated testing; large-aperture telescope; CALIBRATION;
D O I
10.3390/s23156650
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To improve their spatial resolution and detection capabilities, future ground-based optical telescopes will have a size of 30 m, and the aperture of space telescopes will be increased to 10 m. Such large optical systems necessitate the development of large integrated testing equipment. In this study, spectrum and system alignment measurements and wavefront quality checking were performed using the sub-aperture detection method and a fiber-connected Photonics Scanning Pentaprism (PSP). First, the system was aligned using an optical truss, ensuring that the optical axis was properly positioned. Second, using a sub-aperture light beam though the entrance pupil, light spots were formed on the focal plane and transmitted to the spectrometer via fibers to obtain the corresponding spectral components. Then, by taking measurements at different system positions, a full-aperture spectrum response could be reached. Lastly, by photon-integrated interference on the focal plane, intensity interference fringes could be projected at the entrance pupil of the system. And the wavefront quality of the system could be verified by observing the fringe deformation. The measurement accuracy of the optical axis of the system is better than 2 mrad. The spectral measurement accuracy was better than 5%, and the wavefront measurement accuracy surpassed 0.1 wavelengths (1 wavelength = 633 nm). This study effectively enhanced the detection and in situ calibration capabilities of large telescope systems, ensuring that the performance requirements can be met in the design of future telescopes.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Integrated Test System for Large-aperture Telescopes Based on Astrophotonics Interconnections
    Qichang An
    Kun Wang
    Xinyue Liu
    Hongwen Li
    Jiakang Zhu
    Instrumentation, 2024, 11 (01) : 1 - 9
  • [2] Reflective Schmidt-Cassegrain system for large-aperture telescopes
    Brychikhin, M. N.
    Chkhalo, N. I.
    Eikhorn, Ya. O.
    Malyshev, I. V.
    Pestov, A. E.
    Plastinin, Yu. A.
    Polkovnikov, V. N.
    Rizvanov, A. A.
    Salashchenko, N. N.
    Strulya, I. L.
    Toropov, M. N.
    APPLIED OPTICS, 2016, 55 (16) : 4430 - 4435
  • [3] Study on low-order aberration measurements of large-aperture flats based on scanning pentaprism technology
    Qi, Erhui
    Hu, Haixiang
    Luo, Xiao
    APPLIED OPTICS, 2019, 58 (04) : 787 - 793
  • [4] A pupil-scanning device for the measurement of sensor focus on large-aperture tracking telescopes
    Imrie, David A.
    Fantone, Stephen D.
    Zhang, Jian
    Orband, Daniel
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS III, 2008, 6830
  • [5] Large-aperture telescopes in the problems of near-Earth astronomy
    Aleshin, V. P.
    Grishin, E. A.
    Ivlev, O. A.
    Novgorodtsev, D. D.
    Shargorodsky, V. D.
    KINEMATICS AND PHYSICS OF CELESTIAL BODIES, 2016, 32 (05) : 255 - 259
  • [6] Large-aperture telescopes in the problems of near-Earth astronomy
    V. P. Aleshin
    E. A. Grishin
    O. A. Ivlev
    D. D. Novgorodtsev
    V. D. Shargorodsky
    Kinematics and Physics of Celestial Bodies, 2016, 32 : 255 - 259
  • [7] GEOPOTENTIAL SURFACE CORRECTIONS TO LARGE-APERTURE LIQUID MIRROR TELESCOPES
    CANNON, WH
    RUCINSKI, SM
    JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY OF CANADA, 1995, 89 (03) : 99 - 105
  • [8] Large-aperture space optical system testing based on the scanning Hartmann
    Wei, Haisong
    Yan, Feng
    Chen, Xindong
    Zhang, Hao
    Cheng, Qiang
    Xue, Donglin
    Zeng, Xuefeng
    Zhang, Xuejun
    APPLIED OPTICS, 2017, 56 (08) : 2078 - 2083
  • [9] LARGE-APERTURE CATADIOPTRIC SYSTEM
    OFFNER, A
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1966, 56 (10) : 1439 - &
  • [10] Damage Online Inspection in Large-Aperture Final Optics
    Liu, Guodong
    Wei, Fupeng
    Chen, Fengdong
    Peng, Zhitao
    Tang, Jun
    PATTERN RECOGNITION AND COMPUTER VISION (PRCV 2018), PT I, 2018, 11256 : 237 - 248