In-vivo dosimetry in total body irradiation using GafchromicTM EBT-3 film: A retrospective analysis for quality assurance

被引:0
|
作者
Dhivya, S. [1 ,2 ]
Anuradha, C. [2 ]
机构
[1] Apollo Canc Hosp, Dept Radiat Oncol, Chennai, Tamil Nadu, India
[2] VIT Univ, Sch Adv Sci, Vellore, India
来源
关键词
Total body irradiation; in-vivo dosimetry; in-vivo dosimetry in total body irradiation; GafchromicTM EBT-3 flm; mid-plane dosimetry; CLINICAL-APPLICATION; VERIFICATION;
D O I
10.52547/ijrr.21.2.19
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Total Body Irradiation (TBI) is a specialized radiotherapy technique and it varies from routine radiotherapy techniques that involve a complex treatment procedure. It is therefore mandatory to perform an in-vivo dosimetry check to ensure dose accuracy and homogeneity during treatment. There is also a clear demand for in-vivo dose validation which must be reliable. The primary objective of this work is to review in-vivo dosimetry measured for our TBI patients using Film. Materials and Methods: In this study, in-vivo dosimetric data of 185 patients who received TBI during 2015 to 2021 were evaluated. The measurements were performed at 14 anatomical sites using Gafchromic (TM) EBT-3 film (The Ashland Inc., Bridgewater, USA). For midplane dosimetry, a special TBI phantom was designed and used for measurements. Result: For most of the patients, the in-vivo dosimetry result and the mean dose to the whole body were within +/- 10% (90.1% - 110%) of the prescription dose. The standard deviation was calculated for all the patients and the values were observed between 2.4cGy to 24cGy. Also, the analysis shows that both surface and mid-plane dosimetry were within the acceptable limits of +/- 10% of prescription dose. The mean mid-plane dose with film and ionization chamber shows 1.5% variation at the umbilicus. Conclusion: This extensive patient data analysis, as well as the reproducibility of patient dosimetry values and dose homogeneity of +/- 10% from the prescription dose, proves that the TBI treatments at our center meet the acceptable limits and EBT3 films are reliable in TBI in-vivo dosimetry.
引用
收藏
页码:311 / 317
页数:7
相关论文
共 50 条
  • [1] Application of GAFCHROMIC® EBT film for in vivo dosimetry with total body irradiation (TBI) radiotherapy
    Su, F.
    Shi, C.
    Stathakis, S.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2007, 34 (06) : 2420 - 2420
  • [2] Surface Dosimetry of Patients Undergoing Total Body Irradiation: A Retrospective Analysis for Quality Assurance
    Sengupta, Arpita
    Wilke, Derek R.
    Cherpak, Amanda
    Chytyk-Praznik, Krista
    Schella, Jason
    Yewondwossen, Mammo
    Allan, James
    Mulroy, Liam
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (02)
  • [3] SURFACE DOSIMETRY OF PATIENTS UNDERGOING TOTAL BODY IRRADIATION (TBI): A RETROSPECTIVE ANALYSIS FOR QUALITY ASSURANCE
    Sengupta, Arpita
    Wilke, Derek
    Cherpak, Amanda
    Chytyk-Praznik, Krista
    Schella, Jason
    Yewondwossen, Mammo
    Allan, James
    Mulroy, Liam
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S79 - S79
  • [4] Clinical use of Gafchromic EBT4 film for in vivo dosimetry for total body irradiation
    Draeger, Emily
    Guan, Fada
    Lee, Min-Young
    Han, Dae Yup
    Donahue, William
    Chen, Zhe
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (03):
  • [5] In-vivo dosimetry with EBT-3 gafchromic films and thermoluminescent dosimeters in breast cancer radiotherapy treatments
    Fokou, Mvoufo
    Hasford, Francis
    Ndontchueng, Maurice M.
    Tagoe, Samuel A.
    Njantang, Ruth N.
    Dery, Theresa B.
    Simo, Augustin
    Larbi, Kofi O. A.
    Mantheaw, Philip
    Eduful, Ernest
    Motapon, Ousmanou
    HEALTH AND TECHNOLOGY, 2023, 13 (04) : 585 - 600
  • [6] In-vivo dosimetry with EBT-3 gafchromic films and thermoluminescent dosimeters in breast cancer radiotherapy treatments
    Mvoufo Fokou
    Francis Hasford
    Maurice M. Ndontchueng
    Samuel A. Tagoe
    Ruth N. Njantang
    Theresa B. Dery
    Augustin Simo
    Kofi O. A. Larbi
    Philip Mantheaw
    Ernest Eduful
    Ousmanou Motapon
    Health and Technology, 2023, 13 : 585 - 600
  • [7] In Vivo Dosimetry with GAFCHROMIC EBT3 Film in Twice-A-Day Total-Body Irradiation Radiotherapy
    Zhang, X.
    Zhang, Y.
    Behbahani, R.
    Kilian-Meneghin, J.
    Wang, X.
    Simiele, E.
    Zhang, Y.
    Nie, K.
    Yue, N.
    MEDICAL PHYSICS, 2022, 49 (06) : E903 - E903
  • [8] Validation of OSLD In-Vivo Dosimetry for Total Body Irradiation
    Draeger, E.
    Chen, Z.
    Tang, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E877 - E877
  • [9] In vivo dosimetry with MOSFET and EBT3AE film for total skin electron irradiation technique
    Dias, A. G.
    Silva, S.
    Lencart, J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S152 - S153
  • [10] In vivo dosimetry of total body irradiation patients: a 10 years retrospective analysis
    Carminati, Stefano
    Trivellato, Sara
    Ingraito, Chiara
    Tremolada, Valeria E.
    Julita, Chiara
    Arcangeli, Stefano
    De Ponti, Elena
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4779 - S4781