Holmium: Yttrium-aluminum-garnet laser lithotripsy: Is there a difference in ablation rates between short and long pulse duration?

被引:2
|
作者
Ntasiotis, Panteleimon [1 ]
Peteinaris, Angelis [1 ]
Lattarulo, Marco [1 ,2 ]
Tsaturyan, Arman [1 ]
Asutay, Mehmet Kazim [3 ]
Adamou, Constantinos [1 ]
Vagionis, Athanasios [1 ]
Pagonis, Konstantinos [1 ]
Koukiou, Georgia [4 ]
Al-Aown, Abdulrahman [5 ]
Liatsikos, Evangelos [1 ,6 ]
Kallidonis, Panagiotis [1 ]
机构
[1] Univ Patras, Dept Urol, Patras, Greece
[2] Univ Bari, Santissima Annunziata Hosp, Dept Urol, Bari, Italy
[3] Tarsus Publ Hosp, Dept Urol, Mersin, Turkiye
[4] Univ Patras, Dept Phys, Elect Lab, Patras, Greece
[5] Armed Forces Hosp Southern Reg, Dept Urol, Khamis Mushait, Saudi Arabia
[6] Med Univ Vienna, Dept Urol, Vienna, Austria
关键词
Ablation rate; artificial stones; high power laser; holmium; yttrium-aluminum-garnet laser lithotripsy; pulse duration; YAG LASER; STONE FRAGMENTATION; URETEROSCOPY; IMPACT;
D O I
10.4103/ua.ua_111_22
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The high-power holmium: yttrium-aluminum-garnet lasers provide a wide variety of settings for stone disintegration. The aim of this in vitro study is to evaluate the effect of short and long pulse duration on ablation rates on urinary stones.Materials and Methods: Two types of artificial stones were created by BegoStone (TM) with different compositions (15:3 and 15:6, stone/water ratio). Stones with a 15:3 and 15:6 powder-to-water ratio were defined as hard and soft stones, respectively. Lithotripsy was performed with different laser settings using a custom-made in vitro model consisting of a 60 cm long and 19 mm diameter tube. The ablation rate is defined as the final total mass subtracted from the initial total mass and divided to the time of treatment. Stone ablation rates were measured according to different laser settings with total power of 10W (0,5J-20 Hz, 1J-10 Hz, 2J-5 Hz) and 60W (1J-60 Hz, 1,5J-40 Hz, 2J-30 Hz).Results: Higher pulse rates and higher total power settings were related to higher ablation rates. Short pulse duration was more effective on soft stones, whereas long pulse duration was more effective on hard stones. For the same power settings, the highest energy-lowest frequency combination resulted in higher ablation rate in comparison to the lowest energy-higher frequency combination. Finally, short and long pulse average ablation rates do not differ so much.Conclusion: Regardless of the stone type and pulse duration, utilization of higher power settings with higher energies increased the ablation rates. Higher ablation rates were demonstrated for hard stones using long pulse duration, and for soft stones with short pulse duration.
引用
收藏
页码:202 / 206
页数:5
相关论文
共 50 条
  • [1] HOLMIUM - YTTRIUM-ALUMINUM-GARNET LASER FOR ENDOSCOPIC LITHOTRIPSY
    MATSUOKA, K
    IIDA, S
    NAKANAMI, M
    KOGA, H
    SHIMADA, A
    MIHARA, T
    NODA, S
    UROLOGY, 1995, 45 (06) : 947 - 952
  • [2] Systematic evaluation of a holmium: yttrium-aluminum-garnet laser lithotripsy device with variable pulse peak power and pulse duration
    Netsch, Christopher
    Knipper, Sophie
    Tiburtius, Christian
    Gross, Andreas J.
    ASIAN JOURNAL OF UROLOGY, 2014, 1 (01) : 60 - 65
  • [3] Comparison of Different Pulse Modulation Modes for Holmium:Yttrium-Aluminum-Garnet Laser Lithotripsy Ablation in a Benchtop Model
    Terry, Russell S.
    Ho, Derek S.
    Scialabba, Dominick M.
    Whelan, Patrick S.
    Qi, Robert
    Ketterman, Brian T.
    Preminger, Glenn M.
    Zhong, Pei
    Lipkin, Michael E.
    JOURNAL OF ENDOUROLOGY, 2022, 36 (01) : 29 - 37
  • [4] Holmium: yttrium-aluminum-garnet laser with Moses: does it make a difference?
    Corsini, Christian
    de Angelis, Mario
    Villa, Luca
    Somani, Bhaskar K.
    Pietropaolo, Amelia
    Montorsi, Francesco
    Goumas, Ioannis Kartalas
    Traxer, Olivier
    Salonia, Andrea
    Ventimiglia, Eugenio
    CURRENT OPINION IN UROLOGY, 2022, 32 (03) : 324 - 329
  • [5] Holmium:yttrium-aluminum-garnet laser prostatectomy
    Kabalin, JN
    Gilling, PJ
    Fraundorfer, MR
    MAYO CLINIC PROCEEDINGS, 1998, 73 (08) : 792 - 797
  • [6] Radiopaque Laser Fiber for Holmium: Yttrium-Aluminum-Garnet Laser Lithotripsy: Critical Evaluation
    Bach, Thorsten
    Herrmann, T. R.
    Gross, Andreas J.
    JOURNAL OF ENDOUROLOGY, 2012, 26 (06) : 722 - 725
  • [7] Subcapsular renal hematoma after ureteroscopy with holmium:yttrium-aluminum-garnet laser lithotripsy
    Tao, Wei
    Cai, Chun Jie
    Sun, Chuan Yang
    Xue, Bo Xin
    Shan, Yu Xi
    LASERS IN MEDICAL SCIENCE, 2015, 30 (05) : 1527 - 1532
  • [8] Determinants of Holmium: Yttrium-aluminum-garnet Laser Time and Energy During Ureteroscopic Laser Lithotripsy
    Molina, Wilson R.
    Marchini, Giovanni S.
    Pompeo, Alexandre
    Sehrt, David
    Kim, Fernando J.
    Monga, Manoj
    UROLOGY, 2014, 83 (04) : 738 - 744
  • [9] Subcapsular renal hematoma after ureteroscopy with holmium:yttrium-aluminum-garnet laser lithotripsy
    Wei Tao
    Chun Jie Cai
    Chuan Yang Sun
    Bo Xin Xue
    Yu Xi Shan
    Lasers in Medical Science, 2015, 30 : 1527 - 1532
  • [10] Holmium:yttrium-aluminum-garnet lithotripsy efficiency varies with stone composition
    Teichman, JMH
    Vassar, GJ
    Glickman, RD
    UROLOGY, 1998, 52 (03) : 392 - 397