Intraocular Implantable Collamer Lens with a Central Hole Implantation: Safety, Efficacy, and Patient Outcomes

被引:17
|
作者
Wannapanich, Trakanta [1 ,2 ]
Kasetsuwan, Ngamjit [1 ,2 ,3 ,4 ,5 ]
Reinprayoon, Usanee [1 ,2 ,3 ,4 ]
机构
[1] Chulalongkorn Univ, Fac Med, Dept Ophthalmol, Bangkok, Thailand
[2] King Chulalongkorn Mem Hosp, Bangkok, Thailand
[3] King Chulalongkorn Mem Hosp, Chula Refract Surg Ctr, Bangkok, Thailand
[4] Chulalongkorn Univ, King Chulalongkorn Mem Hosp, Fac Med, Excellence Ctr Cornea & Limbal Stem Cell Transplan, Bangkok, Thailand
[5] Chulalongkorn Univ, Fac Med, Dept Ophthalmol, 1873 Rama 4 Rd, Bangkok 10330, Thailand
来源
CLINICAL OPHTHALMOLOGY | 2023年 / 17卷
关键词
posterior chamber lens; phakic intraocular lens; Visian ICL; phakic refractive lens; refractive surgery; PHAKIC IOL ICL; CONTACT-LENS; HIGH MYOPIA; VISUAL PERFORMANCE; CLINICAL-OUTCOMES; OPTICAL-QUALITY; FLUID-DYNAMICS; CORRECT MYOPIA; MODERATE; EYES;
D O I
10.2147/OPTH.S379856
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This review summarizes the available literature and provides updates on the efficacy, safety, and patient outcomes of phakic intraocular lens implantation using implantable collamer lens (ICL), with a focus on newer models with a central port (EVO/EVO+ Visian Implantable Collamer Lens, STAAR Surgical Inc.). All studies included in this review were identified from the PubMed database and were reviewed for relevancy of their topic. Data on hole-ICL implantation performed between October 2018 and October 2022 in 3399 eyes showed a weighted average efficacy index of 1.03 and a weighted average safety index of 1.19 within an average follow-up of 24.7 months. The incidence of complications such as elevated intraocular pressure, cataract, and corneal endothelial cell loss was low. Moreover, both quality of vision and quality of life improved after ICL implantation, confirming the benefits of this procedure. In conclusion, ICL implantation is a promising refractive surgery alternative to laser vision correction with excellent efficacy, safety, and patient outcomes.
引用
收藏
页码:969 / 980
页数:12
相关论文
共 50 条
  • [1] Comparison of intraocular pressure andvault after implantation of implantable collamer lens with and without a central hole
    Haiting Chen
    Guangzeng Niu
    Yuxiang Fan
    Jingxue Ma
    BMC Ophthalmology, 16
  • [2] Comparison of intraocular pressure andvault after implantation of implantable collamer lens with and without a central hole
    Chen, Haiting
    Niu, Guangzeng
    Fan, Yuxiang
    Ma, Jingxue
    BMC OPHTHALMOLOGY, 2016, 16
  • [3] Intraocular Pressure After Implantation of a Phakic Collamer Intraocular Lens With a Central Hole
    Rodriguez-Una, Ignacio
    Pablo Rodriguez-Calvo, Pedro
    Fernandez-Vega Cueto, Luis
    Lisa, Carlos
    Fernandez-Vega Cueto, Andres
    F. Alfonso, Jose
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (04) : 244 - +
  • [4] Clinical outcomes of immediate sequential bilateral phakic intraocular lens implantation and effect of the lens size on central vault of implantable collamer lens implantation
    Chung, Jin Kwon
    Pak, Kibum
    Ha, Seung Joo
    Choi, Kyung Seek
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [5] Refractive outcomes of posterior chamber phakic (Spheric and toric implantable Collamer lens) intraocular lens implantation with a central port design
    Vera, Guillermo
    Zatarain, Naomi
    Jimenez-Collado, David
    Morales, Carlos
    Ramirez-Miranda, Arturo
    Navas, Alejandro
    Gomez-Bastar, Arturo
    Graue-Hernandez, Enrique
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [6] Central flow toric implantable collamer lens implantation
    Navas, Alejandro
    Martinez-Sanchez, Eduardo
    Oliva-Bienzobas, Valeria
    Gomez-Bastar, Arturo
    Jimenez-Corona, Aida
    Lichtinger, Alejandro
    Ramirez-Miranda, Arturo J.
    Graue-Hernandez, Enrique O.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [7] Clinical outcomes and patient satisfaction after Visian Implantable Collamer Lens removal and phacoemulsification with intraocular lens implantation in eyes with induced cataract
    K Kamiya
    K Shimizu
    A Igarashi
    D Aizawa
    T Ikeda
    Eye, 2010, 24 : 304 - 309
  • [8] Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens
    Lee, S. Y.
    Kwon, H. J.
    Ahn, H. S.
    Seo, K. Y.
    Kim, E. K.
    Kim, T-I
    EYE, 2011, 25 (11) : 1409 - 1417
  • [9] Clinical outcomes and patient satisfaction after Visian Implantable Collamer Lens removal and phacoemulsification with intraocular lens implantation in eyes with induced cataract
    Kamiya, K.
    Shimizu, K.
    Igarashi, A.
    Aizawa, D.
    Ikeda, T.
    EYE, 2010, 24 (02) : 304 - 309
  • [10] Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens
    S Y Lee
    H J Kwon
    H S Ahn
    K Y Seo
    E K Kim
    T-I Kim
    Eye, 2011, 25 : 1409 - 1417