Even-number measurement bias with Goldmann applanation tonometry in patients with glaucoma and glaucoma suspects

被引:0
|
作者
Shahid, Alina [1 ]
Patel, Kosha [1 ]
Kingra, Ramanjot K. [1 ]
Rozwat, Anne S. [1 ]
Roberts, Daniel K. [1 ]
机构
[1] Illinois Coll Optometry, Illinois Eye Inst, Dept Clin Educ, Chicago, IL 60616 USA
关键词
Glaucoma; Goldmann applanation tonometry; intraocular pressure; PROGRESSION;
D O I
10.1080/08164622.2024.2302820
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Clinical RelevanceGoldmann applanation tonometry is widely used for the diagnosis and management of glaucoma and its use is considered standard of care. However, the precision of this method may be reduced by a clinician tendency to round to even numbers.BackgroundStudies have previously demonstrated an even-number measurement bias with Goldmann applanation tonometry during examination of a general patient population. Since it has not been determined whether this bias persists among glaucoma suspects and patients with glaucoma, further investigation was conducted.MethodsA retrospective analysis was conducted on a random sample from a large dataset of >69,000 patients seen during a six-year period at an urban, academic primary eye care service. Patients without suspicion of glaucoma, patients with a suspicion of glaucoma, and patients with glaucoma were selected who had Goldmann tonometry performed. Chart reviews were performed to confirm status, and even/odd-numbered Goldmann tonometry measurement frequencies were compared.ResultsThe analysis included 961 controls, 506 glaucoma suspects, 159 ocular hypertensives not taking medication, and 314 patients taking medications who carried a diagnosis of glaucoma or ocular hypertension. Among controls the Goldmann tonometry even/odd digit proportions were 62.8%/37.2% (N = 961, p < 0.0001), and the even-number bias persisted among the other groups with specific even/odd distributions being 61.9%/38.1% (N = 506, p < 0.0001) for glaucoma suspects not taking medications, 66.0%/34.0% (N = 159, p < 0.0001) for ocular hypertensives not taking medications, and 64.3%/35.7% (N = 314, p < 0.0001) for glaucoma/ocular hypertension patients taking medications.ConclusionAn even-number measurement bias with Goldmann tonometry may be prevalent even when the examiner is aware of there being greater importance for intraocular pressure measurement accuracy.
引用
收藏
页码:192 / 195
页数:4
相关论文
共 50 条
  • [1] Even-number Measurement Bias With Goldmann Applanation Tonometry
    Rozwat, Anne
    Roberts, Daniel K.
    JOURNAL OF GLAUCOMA, 2020, 29 (02) : 124 - 126
  • [2] Comparison of IOPen Rebound Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients
    Giacosa, M. F.
    Ungaro, N.
    Gandolfi, S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Effect of Intraocular Pressure Distribution on Analysis of Even-Number Measurement Bias with Goldmann and Automated Tonometry Methods
    Roberts, Daniel K.
    Rozwat, Anne
    Yang, Yongyi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [4] Comparison of PASCAL contour tonometry and Goldmann applanation tonometry in glaucoma patients and healthy subjects
    Barleon, L
    Hoffmann, EM
    Pfeiffer, N
    Grus, FH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [5] Comparison of dynamic contour tonometry with Goldmann applanation tonometry in glaucoma practice
    Halkiadakis, Ioannis
    Patsea, Eleni
    Chatzimichali, Katerina
    Skouriotis, Sotiris
    Chalkidou, Sonia
    Amariotakis, Georgios
    Papakonstadinou, Dimitrios
    Theodossiadis, George
    Amariotakis, Apostolos
    Georgopoulos, Gerasimos
    ACTA OPHTHALMOLOGICA, 2009, 87 (03) : 323 - 328
  • [6] Comparison of dynamic contour tonometry and Goldmann applanation tonometry in glaucoma patients and healthy subjects
    Barleon, Lorenz
    Hoffmann, Esther M.
    Berres, Manfred
    Pfeiffer, Norbert
    Grus, Franz H.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (04) : 583 - 590
  • [7] Comparisons between Pascal dynamic contour tonometry, the TonoPen, and Goldmann applanation tonometry in patients with glaucoma
    Salvetat, Maria L.
    Zeppieri, Marco
    Tosoni, Claudia
    Brusini, Paolo
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (03): : 272 - 279
  • [8] Comparison of handheld rebound tonometry with Goldmann applanation tonometry in children with glaucoma: a cohort study
    Dahlmann-Noor, Annegret Hella
    Puertas, Renata
    Tabasa-Lim, Shenille
    El-Karmouty, Ahmed
    Kadhim, Mustafa
    Wride, Nicholas Kloster
    Lewis, Amanda
    Grosvenor, Dawn
    Rai, Poornima
    Papadopoulos, Maria
    Brookes, John
    Bunce, Catey
    Khaw, Peng Tee
    BMJ OPEN, 2013, 3 (04):
  • [9] The accuracy of Goldmann applanation tonometry over silicone hydrogel contact lenses in patients with glaucoma
    Gomes, Beatriz A. F.
    Turiel, Paulo
    Cavalcanti, Rachel S.
    Moraes, Haroldo V., Jr.
    Santhiago, Marcony R.
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (04): : 297 - 299
  • [10] A Comparison of Goldmann Applanation Tonometry and Rebound Tonometry Measurements Among Patients Attending a Glaucoma Clinic in Southwest Nigeria
    Ashano, O.
    Oderinlo, O.
    Ogunro, A.
    Ashano, E.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2022, 25 (09) : 1542 - 1547