Purity and DNA content of AAV capsids assessed by analytical ultracentrifugation and orthogonal biophysical techniques

被引:23
|
作者
Richter, Klaus [1 ]
Wurm, Christine [1 ]
Strasser, Kim [2 ]
Bauer, Jana [2 ]
Bakou, Maria [1 ]
VerHeul, Ross [3 ]
Sternisha, Shawn [3 ]
Hawe, Andrea [1 ]
Salomon, Michael [2 ]
Menzen, Tim [1 ]
Bhattacharya, Akash [3 ]
机构
[1] Coriolis Pharm Res GmbH, Fraunhoferstr 18 B, D-82152 Martinsried, Germany
[2] Sirion Biotech GmbH, Haag 6, D-82166 Grafelfing, Germany
[3] Beckman Coulter Life Sci, 5350 Lakeview Pkwy S Dr, Indianapolis, IN 46268 USA
关键词
Adeno-associated virus; AAV concentration; AAV titer; Analytical ultracentrifugation; AEX; TEM; Mass photometry; UV-spectroscopy; SIZE-DISTRIBUTION ANALYSIS; SEDIMENTATION-VELOCITY; GENE-THERAPY; VECTORS; QUANTIFICATION; PARTICLE; RECEPTOR; SYSTEMS; EMPTY;
D O I
10.1016/j.ejpb.2023.05.011
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Development and manufacturing adeno-associated virus (AAV)-based vectors for gene therapy requires suitable analytical methods to assess the quality of the formulations during development, as well as the quality of different batches and the consistency of the processes. Here, we compare biophysical methods to characterize purity and DNA content of viral capsids from five different serotypes (AAV2, AAV5, AAV6, AAV8, and AAV9). For this purpose, we apply multiwavelength sedimentation velocity analytical ultracentrifugation (SV-AUC) to obtain the species' contents and to derive the wavelength-specific correction factors for the respective insert-size. In an orthogonal manner we perform anion exchange chromatography (AEX) and UV-spectroscopy and the three methods yield comparable results on empty/filled capsid contents with these correction factors. Whereas AEX and UV-spectroscopy can quantify empty and filled AAVs, only SV-AUC could identify the low amounts of partially filled capsids present in the samples used in this study. Finally, we employ negative-staining transmission electron microscopy and mass photometry to support the empty/filled ratios with methods that classify individual capsids. The obtained ratios are consistent throughout the orthogonal approaches as long as no other impurities and aggregates are present. Our results show that the combination of selected orthogonal methods can deliver consistent empty/filled contents on non-standard genome sizes, as well as information on other relevant critical quality attributes, such as AAV capsid concentration, genome concentration, insert size length and sample purity to characterize and compare AAV preparations.
引用
收藏
页码:68 / 83
页数:16
相关论文
共 2 条
  • [1] AAV analysis by sedimentation velocity analytical ultracentrifugation: beyond empty and full capsids
    Yarawsky, Alexander E.
    Zai-Rose, Valeria
    Cunningham, Hazel M.
    Burgner II, John W.
    DeLion, Michael T.
    Paul, Lake N.
    EUROPEAN BIOPHYSICS JOURNAL, 2023, 52 (4-5) : 353 - 366
  • [2] AAV analysis by sedimentation velocity analytical ultracentrifugation: beyond empty and full capsids
    Alexander E. Yarawsky
    Valeria Zai-Rose
    Hazel M. Cunningham
    John W. Burgner
    Michael T. DeLion
    Lake N. Paul
    European Biophysics Journal, 2023, 52 : 353 - 366