Influence of the Type of Bone Cement Used in Two-Stage Exchange Arthroplasty for Chronic Periarticular Joint Infection on the Spacer Replacement and Reinfection Rate

被引:3
|
作者
Chang, Meng-Wei [1 ]
Wu, Cheng-Ta [2 ]
Yen, Shih-Hsiang [2 ]
Tan, Timothy L. [3 ]
Lin, Po-Chun [2 ]
Kuo, Feng-Chih [2 ,4 ,5 ]
机构
[1] Linkou Chang Gung Mem Hosp, Dept Orthopaed Surg, Taoyuan 333, Taiwan
[2] Kaohsiung Chang Gung Mem Hosp, Dept Orthopaed Surg, Kaohsiung 833, Taiwan
[3] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA 94143 USA
[4] Chang Gung Univ, Coll Med, Kaohsiung 833, Taiwan
[5] Cheng Shiu Univ, Ctr Gen Educ, Kaohsiung 833, Taiwan
关键词
periprosthetic joint infection; commercial antibiotic-loaded bone cement; antibiotic-loaded bone cement spacer; spacer exchange; TOTAL KNEE ARTHROPLASTY; MECHANICAL-PROPERTIES; ANTIBIOTIC ELUTION; RISK-FACTORS; GENTAMICIN; VANCOMYCIN; REVISION; HIP;
D O I
10.3390/jcm12020600
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Antibiotic-loaded bone cement (ALBC) spacers are used in the first stage when treating periprosthetic joint infection (PJI). This study aimed to investigate whether a spacer made from commercial ALBC or plain bone cement with additional antibiotics could affect the spacer exchange rate before reimplantation. Methods: Patients undergoing two-stage exchange arthroplasty due to chronic PJI from January 2014 to August 2021 were retrospectively reviewed. The exclusion criteria included arthroplasty in the setting of septic arthritis, megaprosthesis, atypical pathogen infection, spacer placement unrelated to PJI, and spacer exchange due to mechanical complications. The patient demographics, brand of cement, and microbiology were recorded manually. The primary outcome was the incidence of spacer exchange due to persistent infection and the secondary outcome was the incidence of reinfection after reimplantation. A multivariate logistic regression analysis and Chi-square test were conducted to identify the effect of cement type on the spacer exchange. Results: A total of 334 patients underwent two-stage exchange arthroplasty for PJI. The spacer exchange rates in the commercial and non-commercial ALBC groups were 6.4% and 25.1%, respectively (p = 0.004). After controlling for confounding factors, there were significant differences between the commercial group and non-commercial groups in the spacer exchange rate (adjusted OR = 0.25; 95% CI = 0.72-0.87, p = 0.029). The use of commercial ALBC was not associated with a lower reinfection rate after reimplantation (p = 0.160). Conclusions: In a two-stage exchange arthroplasty scenario, the spacer comprised of commercial ALBC resulted in a lower spacer exchange rate than the plain bone cement, both of which had additional antibiotics. However, the use of commercial ALBC was not associated with a lower incidence of reinfection following reimplantation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Is There a Role for Spacer Exchange in Two-Stage Exchange Arthroplasty for Periprosthetic Joint Infection?
    Kozaily, Elie
    Chisari, Emanuele
    Parvizi, Javad
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (09) : 1 - 12
  • [2] Two-Stage Exchange Arthroplasty for Periprosthetic Joint Infection: The Rate and Reason for the Attrition After the First Stage
    Wang, Qiaojie
    Goswami, Karan
    Kuo, Feng-Chih
    Xu, Chi
    Tan, Timothy L.
    Parvizi, Javad
    JOURNAL OF ARTHROPLASTY, 2019, 34 (11): : 2749 - 2756
  • [3] Results of cement spacer sonication in the second stage of two-stage treatment of shoulder arthroplasty infection
    Torrens, Carlos
    Santana, Fernando
    Puig, Lluis
    Sorli, Luisa
    Alier, Albert
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [4] Results of cement spacer sonication in the second stage of two-stage treatment of shoulder arthroplasty infection
    Carlos Torrens
    Fernando Santana
    Lluis Puig
    Luisa Sorli
    Albert Alier
    Journal of Orthopaedic Surgery and Research, 13
  • [5] The 'apple core' cement spacer for the management of massive bone loss in two-stage revision knee arthroplasty for infection
    Razii, Nima
    Kakar, Rahul
    Morgan-Jones, Rhidian
    JOURNAL OF ORTHOPAEDICS, 2020, 20 : 301 - 304
  • [6] Two-stage exchange Arthroplasty for knee Periprosthetic joint infection exhibit high infection recurrence rate in patients with chronic viral hepatitis
    Jui-ping Chen
    Chih-hsiang Chang
    Yu-chih Lin
    Sheng-hsun Lee
    Hsin-nung Shih
    Yuhan Chang
    BMC Musculoskeletal Disorders, 22
  • [7] Two-stage exchange Arthroplasty for knee Periprosthetic joint infection exhibit high infection recurrence rate in patients with chronic viral hepatitis
    Chen, Jui-Ping
    Chang, Chih-Hsiang
    Lin, Yu-Chih
    Lee, Sheng-Hsun
    Shih, Hsin-Nung
    Chang, Yuhan
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [8] The Influence of Spacer Design on the Rate of Complications in Two-Stage Revision Hip Arthroplasty
    Jones, Christopher W.
    Selemon, Nicolas
    Nocon, Allina
    Bostrom, Mathias
    Westrich, Geoffrey
    Sculco, Peter K.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (06): : 1201 - 1206
  • [9] Evidence of MRSE on a gentamicin and vancomycin impregnated polymethyl-methacrylate (PMMA) bone cement spacer after two-stage exchange arthroplasty due to periprosthetic joint infection of the knee
    Schmolders, Jan
    Hischebeth, Gunnar T. R.
    Friedrich, Max J.
    Randau, Thomas M.
    Wimmer, Matthias D.
    Kohlhof, Hendrik
    Molitor, Ernst
    Gravius, Sascha
    BMC INFECTIOUS DISEASES, 2014, 14
  • [10] Evidence of MRSE on a gentamicin and vancomycin impregnated polymethyl-methacrylate (PMMA) bone cement spacer after two-stage exchange arthroplasty due to periprosthetic joint infection of the knee
    Jan Schmolders
    Gunnar TR Hischebeth
    Max J Friedrich
    Thomas M Randau
    Matthias D Wimmer
    Hendrik Kohlhof
    Ernst Molitor
    Sascha Gravius
    BMC Infectious Diseases, 14