Design of highly selective, and sensitive screen-printed electrochemical sensor for detection of uric acid with uricase immobilized polycaprolactone/polyethylene imine electrospun nanofiber

被引:9
|
作者
Muhammad, Fakhriy [1 ]
Dik, Gamze [1 ]
Kolak, Seda [1 ]
Gedik, Kubra Karadas [1 ]
Bakar, Busra [1 ]
Ulu, Ahmet [1 ]
Ates, Burhan [1 ]
机构
[1] Inonu Univ, Fac Arts & Sci, Dept Chem, Biochem & Biomat Res Lab, TR-44280 Malatya, Turkey
关键词
Electrospun nanofiber; Uricase; Enzyme immobilization; Quantum dot screen printed electrode; Differential pulse voltammetry; Uric acid; Biosensor; QUANTUM DOTS; BIOSENSOR; STABILITY; BLUE; POLYETHYLENIMINE; MEDIATOR; POLYMER;
D O I
10.1016/j.electacta.2022.141675
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Uric acid (UA) plays a significant role in nerve center, human metabolism, and kidney system. Therefore, it is necessary to establish a simple, rapid, and sensitive detection method for UA. In recent years, researchers have been highly attracted by nanomaterials with satisfactory functions in electrochemical applications. In this study, polycaprolactone (PCL)/polyethylene imine (PEI) nanofiber membranes were prepared and used for the immobilization of uricase (UOx). The prepared membranes were characterized in terms of structure, composi-tion, and morphology. Afterward, the quantum dot screen printed electrode (QD SPCE) was modified with PCL/ PEI nanofiber membranes with and without methylene blue (MB) as an electron mediator. The electrochemical performance of the developed sensors was investigated by cyclic voltammetry (CV), differential pulse voltam-metry (DPV), and electrochemical impedance spectroscopy (EIS). Under the optimal conditions, the modified sensors provided a broad linear range (5.0-52.0 mu M) for the electrochemical detection of UA. Limit of detection (LoD) values were determined as 3.96 mu M and 1.85 mu M for the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/ QD SPCE, respectively. The four-week stability results showed the change in current for the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/QD SPCE to be 92% and 87%, respectively. Additionally, in the mixed interference test remaining current ratios for UA were 95% and 82% for the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/ QD SPCE, respectively. Most importantly, the effectiveness of the electrodes was also verified in real sample detection with satisfactory recovery (similar to 98-112%). Overall, the results showed that the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/QD SPCE have the advantages of simplicity, high sensitivity, and good selectivity for UA determination.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Fabrication of electrospun polycaprolactone/chitosan nanofiber-modified screen-printed electrode for highly sensitive detection of diazinon in food analysis
    Topsoy, Oguz Kagan
    Muhammad, Fakhriy
    Kolak, Seda
    Ulu, Ahmet
    Gungor, Oznur
    Simsek, Murat
    Koytepe, Suleyman
    Ates, Burhan
    MEASUREMENT, 2022, 187
  • [2] An electrochemical biosensor based on multi-wall carbon nanotube–modified screen-printed electrode immobilized by uricase for the detection of salivary uric acid
    Weishan Shi
    Jing Li
    Jie Wu
    Qianying Wei
    Cuili Chen
    Ning Bao
    Chunmei Yu
    Haiying Gu
    Analytical and Bioanalytical Chemistry, 2020, 412 : 7275 - 7283
  • [3] Highly Sensitive and Selective Graphene Nanoribbon Based Enzymatic Glucose Screen-Printed Electrochemical Sensor
    Gricar, Ema
    Radic, Josip
    Genorio, Bostjan
    Kolar, Mitja
    SENSORS, 2022, 22 (24)
  • [4] An electrochemical biosensor based on multi-wall carbon nanotube-modified screen-printed electrode immobilized by uricase for the detection of salivary uric acid
    Shi, Weishan
    Li, Jing
    Wu, Jie
    Wei, Qianying
    Chen, Cuili
    Bao, Ning
    Yu, Chunmei
    Gu, Haiying
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (26) : 7275 - 7283
  • [5] Electrochemical detection of uric acid using graphite screen-printed electrodes modified with Prussian blue/poly(4-aminosalicylic acid)/Uricase
    da Cruz, Filipe Soares
    Paula, Fernanda de Souza
    Franco, Diego Leoni
    Pio dos Santo, Wallans Torres
    Ferreira, Lucas Franco
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 806 : 172 - 179
  • [6] SCREEN-PRINTED ELECTRODES MADE ON STONE PAPER SUBSTRATE FOR URIC ACID ELECTROCHEMICAL DETECTION
    Varodi, Codruta
    Pogacean, Florina
    Gheorghe, Marin
    Barbu-Tudoran, Lucian
    Pruneanu, Stela
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2020, 65 (02): : 233 - 242
  • [7] Graphene oxide modified screen-printed electrode for highly sensitive and selective electrochemical detection of ciprofloxacin residues in milk
    Pan, Ming
    Guo, Peipei
    Liu, Haifeng
    Lu, Jiawei
    Xie, Qiubo
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2021, 12 (01)
  • [8] Graphene oxide modified screen-printed electrode for highly sensitive and selective electrochemical detection of ciprofloxacin residues in milk
    Ming Pan
    Peipei Guo
    Haifeng Liu
    Jiawei Lu
    Qiubo Xie
    Journal of Analytical Science and Technology, 12
  • [9] Graphite carbon nitride-modified screen-printed electrode as a highly sensitive and selective sensor for detection of amaranth
    Jahani, Peyman Mohammadzadeh
    Aflatoonian, Mohammad Reza
    Rayeni, Reza Abbasi
    Di Bartolomeo, Antonio
    Mohammadi, Sayed Zia
    FOOD AND CHEMICAL TOXICOLOGY, 2022, 163
  • [10] Uricase biosensor based on a screen-printed electrode modified with Prussian blue for detection of uric acid in human blood serum
    Piermarini, Silvia
    Migliorelli, Davide
    Volpe, Giulia
    Massoud, Renato
    Pierantozzi, Andrea
    Cortese, Claudio
    Palleschi, Giuseppe
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 179 : 170 - 174