Electro-templating of prussian blue nanoparticles in PEDOT:PSS and soluble silkworm protein for hydrogen peroxide sensing

被引:10
|
作者
Uzuncar, Sinan [1 ]
Kac, Huseyin [2 ]
Ak, Metin [3 ]
机构
[1] Zonguldak Bulent Ecevit Univ, Engn Fac, Environm Engn Dept, TR-67100 Zonguldak, Turkiye
[2] Middle East Tech Univ, Fac Art & Sci, Chem Dept, TR-06800 Ankara, Turkiye
[3] Pamukkale Univ, Fac Sci, Chem Dept, TR-20070 Denizli, Turkiye
关键词
poly(3; 4-ethylenedioxythiophene); PBNPs; Silkworm protein; Electro-template polymerization; Hydrogen peroxide; SCREEN-PRINTED ELECTRODE; ELECTROCHEMICAL OXIDATION; SPONTANEOUS DEPOSITION; STABILITY IMPROVEMENT; GRAPHENE OXIDE; THIN-FILMS; AMIDE-I; COMPOSITE; POLYMERS; POLY(3,4-ETHYLENEDIOXYTHIOPHENE);
D O I
10.1016/j.talanta.2022.123841
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, we demonstrate a high-accuracy H2O2 selective organic-inorganic 3D-heterointerface based on catalyt-ically in-situ reduced Prussian-blue nanoparticles (PBNPs), Poly (3,4-ethylene dioxythiophene):poly (styrene sulfonic acid) (PEDOT:PSS) and water-soluble Silkworm protein (SWp). PBNPs were immobilized on an indium tin oxide-coated glass (ITO) electrode through the electrochemical polymerization process of PEDOT:PSS and the yielding intertwining composite was templated by the use of SWp, simultaneously. Since PSS and SWp act as poly-anionic and poly-cationic charge compensating elements, the sensing system's potential cycling and amperometric response stability have been significantly enhanced thanks to the arising physical blockage effect. Constructed sensing system showed a substantially high sensitivity (1031.7 mu A mM-1 cm-2) and a low limit of detection value (LOD, 0.29 mu M) between 1 and 130 mu M H2O2. Eliminating the possible signal disruptions by common anion and cations in tap water, the (PEDOT:PSS:PB):SWp interface successfully selected H2O2 between the concentration of 10-40 mu M with high recovery and relatively low RSDs oscillating between 94.2-110.9% and 2.9-5.1%, respectively. It is thought that the proposed heterointerface can be used in the field of sensor, biosensor and fuel cell systems run by H2O2 assay based on 3D scaffold-templated conductive polymer-PBNPs network.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Novel synthesis of Prussian blue nanoparticles and nanocomposite sol: Electro-analytical application in hydrogen peroxide sensing
    Pandey, Prem C.
    Pandey, Ashish K.
    ELECTROCHIMICA ACTA, 2013, 87 : 1 - 8
  • [2] Enzymeless voltammetric hydrogen peroxide sensor based on the use of PEDOT doped with Prussian Blue nanoparticles
    Wang, Junjie
    Wang, Yu
    Cui, Min
    Xu, Shenghao
    Luo, Xiliang
    MICROCHIMICA ACTA, 2017, 184 (02) : 483 - 489
  • [3] Enzymeless voltammetric hydrogen peroxide sensor based on the use of PEDOT doped with Prussian Blue nanoparticles
    Junjie Wang
    Yu Wang
    Min Cui
    Shenghao Xu
    Xiliang Luo
    Microchimica Acta, 2017, 184 : 483 - 489
  • [4] Tetrahydrofuran and hydrogen peroxide mediated conversion of potassium hexacyanoferrate into Prussian blue nanoparticles: Application to hydrogen peroxide sensing
    Pandey, P. C.
    Panday, Digvijay
    ELECTROCHIMICA ACTA, 2016, 190 : 758 - 765
  • [5] Electrodeposition of Prussian blue nanoparticles on polyaniline coated halloysite nanotubes for nonenzymatic hydrogen peroxide sensing
    Sheng, Qinglin
    Zhang, Dan
    Wu, Qian
    Zheng, Jianbin
    Tang, Hongsheng
    ANALYTICAL METHODS, 2015, 7 (16) : 6896 - 6903
  • [6] A PEDOT:PSS conductive hydrogel incorporated with Prussian blue nanoparticles for wearable and noninvasive monitoring of glucose
    Xu, Changshun
    Jiang, Danfeng
    Ge, Yuancai
    Huang, Liping
    Xiao, Yang
    Ren, Xueqian
    Liu, Xiaohu
    Zhang, Qingwen
    Wang, Yi
    CHEMICAL ENGINEERING JOURNAL, 2022, 431
  • [7] A PEDOT:PSS conductive hydrogel incorporated with Prussian blue nanoparticles for wearable and noninvasive monitoring of glucose
    Xu, Changshun
    Jiang, Danfeng
    Ge, Yuancai
    Huang, Liping
    Xiao, Yang
    Ren, Xueqian
    Liu, Xiaohu
    Zhang, Qingwen
    Wang, Yi
    Chemical Engineering Journal, 2022, 431
  • [8] Freestanding Films of Reduced Graphene Oxide Fully Decorated with Prussian Blue Nanoparticles for Hydrogen Peroxide Sensing
    Martins, Vitor H. N.
    da Silva, Monize M.
    Goncalves, Daniel A.
    Presser, Volker
    Husmann, Samantha
    Souza, Victor H. R.
    ACS OMEGA, 2024, 9 (29): : 31569 - 31577
  • [9] Spontaneous Growth of Prussian Blue Nanoparticles on Three Dimensional Porous PEDOT for Enhanced Catalytic Reduction and Sensitive Detection of Hydrogen Peroxide
    Yang, Min
    Liu, Ying
    Song, Yonggui
    Zhao, Guochun
    Tan, Haiyan
    Zhang, Qiuping
    Xu, Fugang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (05): : 4428 - 4443
  • [10] Enhanced hydrogen peroxide sensing based on Prussian Blue modified macroporous microelectrodes
    Mokrushina, Anna V.
    Heim, Matthias
    Karyakina, Elena E.
    Kuhn, Alexander
    Karyakin, Arkady A.
    ELECTROCHEMISTRY COMMUNICATIONS, 2013, 29 : 78 - 80