Evaluation of CO2 Emission and Local Flexibility by Water Pumping Scheduling in Water Distribution System

被引:0
|
作者
Sugimura, Shuhei [1 ,2 ]
Tanabe, Takayuki [2 ]
Hayashi, Yasuhiro [1 ]
机构
[1] Waseda Univ, Dept Adv Sci & Engn, Tokyo 1698555, Japan
[2] Meidensha Corp, Power Infrastruct Business Sales & Engn Grp, Tokyo 1416029, Japan
关键词
carbon neutral; net zero; energy management; water pump; climate change; CO2; emissions; photovoltaic;
D O I
10.1002/tee.23955
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, the amount of the photovoltaic (PV) system has been rapidly increasing from the viewpoint of carbon neutral. There are concerns about voltage rises and grid congestion in the electrical distribution network because of large-scale PV increases. In order to address these issues, we focused on the control of water supply pumps in the water distribution system, which is infrastructure equipment for consumers. By controlling the start/stop of the water pump, it is expected to contribute to the power distribution system by increasing Demand Response (DR) and reduce CO2 emission from the electricity used by the pump. In this paper, with the aim of constructing an optimal operation planning method for water pumps that can evaluate DR and CO2 reduction effects, the optimal operation plan is formulated as a mixed integer linear programming problem. We numerical evaluated impact of water pump operation for CO2 emission and electrical distribution network. (c) 2023 The Authors. IEEJ Transactions on Electrical and Electronic Engineering published by Institute of Electrical Engineer of Japan and Wiley Periodicals LLC.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 50 条
  • [1] A water pumping scheduling method in water distribution system with providing balancing reserves to power system
    Negishi S.
    Ikegami T.
    IEEJ Transactions on Power and Energy, 2019, 139 (12) : 757 - 766
  • [2] Evaluation on water balance and amine emission in CO2 capture
    Liu, Fei
    Qi, Zhifu
    Fang, Mengxiang
    Wang, Tao
    Yi, Ningtong
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2021, 112
  • [3] Solar Energy Application in Drainage Pumping Stations to Save Water and Reducing CO2 Emission
    Eshra, Nadia M.
    Salem, Mariam G.
    ENERGY REPORTS, 2020, 6 : 354 - 366
  • [4] Modelling photovoltaic water pumping systems and evaluation of their CO2 emissions mitigation potential
    Ould-Amrouche, S.
    Rekioua, D.
    Hamidat, A.
    APPLIED ENERGY, 2010, 87 (11) : 3451 - 3459
  • [5] The CO2 Emission Factor of Water in Japan
    Shimizu, Yasutoshi
    Dejima, Satoshi
    Toyosada, Kanako
    WATER, 2012, 4 (04): : 759 - 769
  • [6] Energy efficiency in a water supply system:Energy consumption and CO2 emission
    Helena M.RAMOS
    Filipe VIEIRA
    Dídia I.C.COVAS
    WaterScienceandEngineering, 2010, 3 (03) : 331 - 340
  • [7] Energy efficiency in a water supply system: Energy consumption and CO2 emission
    Ramos, Helena M.
    Vieira, Filipe
    Covas, Didia I. C.
    WATER SCIENCE AND ENGINEERING, 2010, 3 (03) : 331 - 340
  • [8] Robust Scheduling for Pumping in a Water Distribution System under the Uncertainty of Activating Regulation Reserves
    Negishi, Shintaro
    Ikegami, Takashi
    ENERGIES, 2021, 14 (02)
  • [9] Optimal Pumping Scheduling for Complex Irrigation Water Distribution Systems
    Reca, Juan
    Garcia-Manzano, Alfonso
    Martinez, Juan
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2014, 140 (05) : 630 - 637
  • [10] Experimental evaluation of CO2 water heater
    Hwang, YH
    Radermacher, R
    NATURAL WORKING FLUIDS'98: IIR - GUSTAV LORENTZEN CONFERENCE, 1998, 1998 (04): : 368 - 375