An ex vivo headspace gas chromatography-mass spectrometry method for the determination of short-chain siloxanes in silicon oil tamponades used in ophthalmic surgery

被引:1
|
作者
Riboni, Nicolo [1 ]
Ribezzi, Erika [1 ]
Marraffa, Enrico [1 ]
Mora, Paolo [2 ]
Bellucci, Carlo [2 ]
Bianchi, Federica [1 ]
Careri, Maria [1 ]
机构
[1] Univ Parma, Dept Chem Life Sci & Environm Sustainabil, Parco Area Sci 17-A, I-43124 Parma, Italy
[2] Univ Hosp Parma, Ophthalmol Unit, Via Gramsci 14, I-43100 Parma, Italy
关键词
Gas chromatography -mass spectrometry; Headspace extraction; Short -chain siloxanes; Central composite design; Silicone oil; Retinal detachment; REMOVAL;
D O I
10.1016/j.jpba.2023.115871
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Being able to facilitate retinal reattachment by preventing water migration into the subretinal space, silicone oils are widely used as long-term intraocular tamponade to treat cases of retinal detachment. Various commercial tamponades constituted by linear polydimethylsiloxane polymers with different molecular weights and cyclic impurities are available. In this study, for the first time, an untargeted headspace-gas-chromatography-mass spectrometry (HS-GC-MS) method was developed to identify low-molecular weight contaminants in three different types of silicone oil tamponades, namely Siluron 2000, RS-OIL ECS5000 and Densiron Xtra. Both commercial and post-operative tamponades were analysed to screen for the different classes of compounds present in the samples. The most abundant classes were short-chain siloxanes, fluorinated compounds, and hydrocarbons. To quantify the siloxanes present in the samples, a targeted HS-GS-MS was optimized using a central composite design and validated according to guidelines for bioanalytical methods. Lower limits of quantification in the low mu g/L range, good precision with RSD% < 12% and accuracy with recovery rates in the 81 ( +/- 7) - 96 (+/- 4) % range were achieved. Short-chain siloxanes were quantified in both commercial and postoperative tamponades, being the RS-OIL ECS5000 characterized by the highest concentration levels of the investigated analytes. By contrast, Densiron Xtra tamponades showed the lowest amount of short-chain siloxanes, observing a general decrease in their concentration levels according to the residence time in the eyes.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Determination of Short-chain Fatty Acids in Well and Rock Salt by Headspace Gas Chromatography-Mass Spectrometry
    Feng Feng
    Fan Guang-Yu
    Liu Tong
    Zhang Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (02) : 244 - 248
  • [2] Establishment of Gas Chromatography-Mass Spectrometry Method of a Short-chain Fatty Acid
    Bu Z.
    Zheng S.
    Wang J.
    Xia Y.
    Ai L.
    Wang C.
    Journal of Chinese Institute of Food Science and Technology, 2023, 23 (09) : 261 - 265
  • [3] Derivatization-free determination of short-chain volatile amines in human plasma and urine by headspace gas chromatography-mass spectrometry
    Neyer, Peter
    Bernasconi, Luca
    Fuchs, Jens A.
    Allenspach, Martina D.
    Steuer, Christian
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2020, 34 (02)
  • [4] Alternative method for gas chromatography-mass spectrometry analysis of short-chain fatty acids in faecal samples
    Garcia-Villalba, Rocio
    Gimenez-Bastida, Juan A.
    Garcia-Conesa, Maria T.
    Tomas-Barberan, Francisco A.
    Carlos Espin, Juan
    Larrosa, Mar
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (15) : 1906 - 1913
  • [5] Quantification of Short-Chain Chlorinated Paraffins by Deuterodechlorination Combined with Gas Chromatography-Mass Spectrometry
    Gao, Yuan
    Zhang, Haijun
    Zou, Lili
    Wu, Ping
    Yu, Zhengkun
    Lu, Xianbo
    Chen, Jiping
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2016, 50 (07) : 3746 - 3753
  • [6] An Improved Method to Quantify Short-Chain Fatty Acids in Biological Samples Using Gas Chromatography-Mass Spectrometry
    Kim, Kyeong-Seog
    Lee, Yujin
    Chae, Woori
    Cho, Joo-Youn
    METABOLITES, 2022, 12 (06)
  • [7] Development of a headspace solid-phase microextraction gas chromatography-mass spectrometric method for the determination of short-chain fatty acids from intestinal fermentation
    Bianchi, F.
    Dall'Asta, M.
    Del Rio, D.
    Mangia, A.
    Musci, M.
    Scazzina, F.
    FOOD CHEMISTRY, 2011, 129 (01) : 200 - 205
  • [8] An isotope dilution headspace method with gas chromatography-mass spectrometry for determination of propylene oxide in food
    Cao, Xu-Liang
    Corriveau, Jeannette
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (04): : 482 - 486
  • [9] Development of gas chromatography-mass spectrometry following headspace single-drop microextraction and simultaneous derivatization for fast determination of short-chain aliphatic amines in water samples
    Deng, Chunhui
    Li, Ning
    Wang, Lei
    Zhang, Xiangmin
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1131 (1-2) : 45 - 50
  • [10] Quantification of Free Short-Chain Fatty Acids in Raw Cow Milk by Gas Chromatography-Mass Spectrometry
    Wu, Xufang
    Wang, Fengen
    Chen, Meiqing
    Wang, Jiaqi
    Zhang, Yangdong
    FOODS, 2023, 12 (07)