Cyclic behavior of dual-steel beam-to-column welded flange-bolted web connections

被引:0
|
作者
Hu, Fangxin [1 ]
Wang, Zhan [1 ,2 ]
机构
[1] South China Univ Technol, Sch Civil Engn & Transportat, Guangzhou 510640, Peoples R China
[2] South China Univ Technol, State Key Lab Subtrop Bldg & Urban Sci, Guangzhou 510640, Peoples R China
基金
中国国家自然科学基金;
关键词
High-strength steel; Dual-steel; Beam-to-column connection; Welded flange-bolted web connection; Cyclic; Experiment; HIGH-STRENGTH STEEL; SEISMIC BEHAVIOR; CODIFICATION; PERFORMANCE; TESTS;
D O I
10.1016/j.tws.2023.111452
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cyclic loading tests on dual-steel beam-to-column welded flange-bolted web connections were conducted to quantify their moment resistance, plastic deformation and energy dissipation capacities. The test program consisted of five one-sided connection specimens, where Q355 grade beams and Q690 grade columns were used, to study the effects of beam-to-column welded flange connection details and panel zone shear strength on the connection seismic performance. Two types of welded connection details were considered; one was the traditional complete-joint-penetration (CJP) welded connections by use of backing bars, and the other type was those with the bottom backing bar further reinforced by a fillet weld. Three column web thicknesses were designed to arrive at strong, intermediate and weak panel zones, respectively. It was found that the CJP weld with the backing bar reinforced only under the bottom beam flange produced satisfactory performance and accommodated plastic rotations larger than 0.03 rad, while a maximum plastic rotation of 0.04 rad could be developed in the high-strength steel panel zone before fracture occurred. These results evidenced that those dual-steel connections could still sustain high seismic deformation demands.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Cyclic behavior of high-strength steel beam-to-column welded flange-bolted web connections
    Hu F.
    Wang Z.
    Thin-Walled Structures, 2024, 201
  • [2] Cyclic performance of repaired welded unreinforced flange-bolted web connections
    Chung, Yu-Lin
    He, Geng-Jhou
    Earthquake and Structures, 2024, 27 (06): : 457 - 469
  • [3] Fracture strength of welded flange-bolted web connections
    Job, CB
    Chen, WF
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1999, 125 (05): : 565 - 571
  • [4] Fracture strength of welded flange-bolted web connections
    Joh, Changbin
    Chen, Wai-Fah
    Journal of structural engineering New York, N.Y., 1999, 125 (05): : 565 - 572
  • [5] Seismic Enhancement of Welded Unreinforced Flange-Bolted Web Steel Moment Connections
    Morrison, Machel Leigh
    Schweizer, Douglas Quinn
    Hassan, Tasnim
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (11)
  • [6] Cyclic behavior of bolted and welded beam-to-column joints
    Yang, Cheol Min
    Kim, Young Moon
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2007, 49 (05) : 635 - 649
  • [7] Seismic behaviour of high-strength steel welded flange-bolted web connections
    Hu, Fangxin
    Wang, Zhan
    ce/papers, 2023, 6 (3-4) : 650 - 654
  • [8] Low-cycle fatigue test on the welded flange-bolted web type beam-to-column connection focusing on arrangement of web bolt
    Yamada S.
    Lee D.
    Kishiki S.
    Ishida T.
    Miki N.
    1600, Architectural Institute of Japan (81): : 1541 - 1551
  • [9] TESTS OF BOLTED BEAM-TO-COLUMN FLANGE MOMENT CONNECTIONS
    STANDIG, KF
    RENTSCHLER, GP
    CHEN, WF
    WELDING RESEARCH COUNCIL BULLETIN, 1976, (218): : 1 - 17
  • [10] WELDED AND BOLTED BEAM-TO-COLUMN CONNECTIONS.
    Witteveen, Jelle
    Stark, Jan W.B.
    Bijlaard, Frans S.K.
    Zoetemeijer, Piet
    1982, 108 (ST2): : 433 - 455