Efficiency Assessment of Multidetector-Row Computed Tomographic Angiography Using Reconstruction With Locoregional Perforator Flaps

被引:3
|
作者
Badiul, Pavlo O. [1 ,2 ]
Sliesarenko, Sergii V. [2 ]
Cherednychenko, Nataliia O. [3 ]
Morgun, Olga V. [4 ]
机构
[1] Minist Hlth Ukraine, Dnipropetrovsk Med Acad, Dnipro, Ukraine
[2] Municipal Hosp, Burn & Plast Surg Ctr, Dnipro, Ukraine
[3] Minist Hlth Ukraine, Dnipropetrovsk Med Acad, Oncol & Radiol Dept, Dnipro, Ukraine
[4] Family Med Clin, Med Ctr, Dnipro, Ukraine
关键词
CT angiography; perforator flaps; perforator vessels; reconstructive surgery; TRUNK RECONSTRUCTION; EFFICACY; DOPPLER; ARTERY;
D O I
10.1177/22925503211024750
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Reconstruction with the use of perforator flaps makes it possible to make the skin surface resistant to the influence of mechanical factors and as similar to the lost skin cover as possible. However, while planning any flap, along with the design of the required shape and size, its blood supply should be taken into account to ensure optimal viability. Therefore, the task to precisely determine the topographic-anatomical relationships suitable for the formation of a pedicle of perforators is still relevant. The aim of this study was to increase the efficiency of surgical reconstruction of wound defects by transposition of locoregional perforator flaps. Methods: The authors conducted a retrospective analysis of 72 cases of reconstruction by means of locoregional perforator flaps with vascular pedicle detachment to determine the efficiency of preoperative diagnostic preparation with the help of multidetector-row computed tomographic angiography (MDCT) in the process of reconstruction. Thirty-seven individual cases of surgical interventions were chosen using a case-controlled study from the study group when MDCT with angiography was used for preoperative planning of perforator flaps, as well as 35 control cases similar in terms of important predictive peculiarities with the reconstruction at the same level of difficulty. The patient groups were precisely matched by gender (P = .950), age (P = .804), flap area (P = .192), and type of reconstruction that was performed. Results: In all cases, the location of the perforator with a diameter greater than 1.0 mm was marked. All perforators determined during MDCT scanning were faultlessly localized intraoperatively. The distance between the intraoperative position of the perforator and the position obtained in the result of the examination did not exceed 1 cm. There was no need to change the planned design of the flap intraoperatively. In all cases where MDCT was performed, the duration of the surgical procedure varied from 60 to 150 minutes (average: 120.77 [18.90] minutes) and was reduced by 49.40 minutes (95% CI: 39.17-59.63) compared with the patients who did not undergo preoperative visualization of perforators where the average duration of the operation was 170.17 (19.19) minutes (from 140 to 220 minutes). Among the patients examined by MDCT, surgical complications were noted in 5 cases (13.51%) compared to 14 cases (40.00%) in the control group. Conclusions: The preoperative MDCT for the locoregional perforator flap reconstruction makes it possible to increase the efficiency of patient treatment given the reduction in surgery duration by 49.40 minutes (95% CI: 39.17-59.63) on average and the reduction in the level of postsurgery complications from 40% to 13.5% compared with the group of patients in whom presurgical visualization was not performed (P = .031).
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [1] Multidetector-row Computed Tomographic Angiography in the Planning of the Local Perforator Flaps
    Badiul, Pavlo O.
    Sliesarenko, Sergii V.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2015, 3 (09)
  • [2] Multidetector-row computed tomography in the planning of abdominal perforator flaps
    Masia, J.
    Clavero, J. A.
    Larranaga, J. R.
    Alomar, X.
    Pons, G.
    Serret, P.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2006, 59 (06): : 594 - 599
  • [3] Multidetector-Row Computed Tomographic Analysis of the Superficial Palmar Branch of Radial Artery Perforator Flaps
    Nguyen Doan Tien Linh
    Ono, Shimpei
    Akiyama, Goh
    Cho, Hoyu
    Hayashi, Hiromitsu
    Ogawa, Rei
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2022, 150 (05) : 1049 - 1057
  • [4] Impact of perforator mapping using multidetector-row computed tomographic angiography on free thoracodorsal artery perforator flap transfer
    Mun, Goo-Hyun
    Kim, Hyung-Joon
    Cha, Myung-Kyu
    Kim, Wan-Yuk
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 122 (04) : 1079 - 1088
  • [5] Predesigned Breast Shaping Assisted by Multidetector-Row Computed Tomographic Angiography in Autologous Breast Reconstruction
    Dionyssiou, Dimitrios
    Demiri, Efterpi
    Tsimponis, Antonios
    Boorman, John
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 133 (02) : 100E - 108E
  • [6] The Utility of Multidetector-Row Computed Tomography Angiography for Evaluating Perforators of Fibular Osteocutaneous Flaps
    Satoh, Takashi
    Kimata, Yoshihiro
    Hasegawa, Kenjiro
    Namba, Yuzaburo
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2011, 27 (01) : 29 - 36
  • [7] THE EFFECT OF A SALINE CHASER FOR CONTRAST ENHANCEMENT OF MULTIDETECTOR-ROW COMPUTED TOMOGRAPHIC ANGIOGRAPHY IN CATTLE
    Lee, K.
    Kishimoto, M.
    Shimizu, J.
    Iwasaki, T.
    Miyake, Y.
    Yamada, K.
    VETERINARY RADIOLOGY & ULTRASOUND, 2010, 51 (02) : 216 - 216
  • [8] Minimally invasive diagnosis of persistent sciatic artery by multidetector-row computed tomographic angiography
    Hiromitsu Hayashi
    Hisashi Yoshihara
    Ryo Takagi
    Tatsuo Kumazaki
    Heart and Vessels, 2006, 21 : 267 - 269
  • [9] Minimally invasive diagnosis of persistent sciatic artery by multidetector-row computed tomographic angiography
    Hayashi, Hiromitsu
    Yoshihara, Hisashi
    Takagi, Ryo
    Kumazaki, Tatsuo
    HEART AND VESSELS, 2006, 21 (04) : 267 - 269
  • [10] Accessory renal artery stenosis and hypertension: Are these correlated? Evaluation using multidetector-row computed tomographic angiography
    Saba, L.
    Sanfilippo, R.
    Montisci, R.
    Conti, M.
    Mallarini, G.
    ACTA RADIOLOGICA, 2008, 49 (03) : 278 - 284