Thermodynamic assessment of the dry-cooling supercritical Brayton cycle in a direct-heated solar power tower plant enabled by CO2-propane mixture

被引:11
|
作者
Ma, Ning [1 ]
Meng, Fugui [1 ]
Hong, Wenpeng [1 ]
Li, Haoran [1 ]
Niu, Xiaojuan [1 ]
机构
[1] Northeast Elect Power Univ, Sch Energy & Power Engn, Jilin 132012, Peoples R China
基金
中国国家自然科学基金;
关键词
Supercritical Brayton cycle; Carbon dioxide; Binary mixture; Solar power tower plant; Thermodynamic analysis; Genetic algorithm optimization; CO2; PERFORMANCE; OPTIMIZATION; ENERGY; RECEIVER; SYSTEM;
D O I
10.1016/j.renene.2022.12.084
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper proposes an improved recompression combined cycle configuration to explore the potential of using CO2-propane in a direct-heating solar power tower (SPT) plant. The effects of critical parameters on overall performance were detailly analyzed. The exergy distribution of CO2 and CO2-propane cycles was compared respectively after being optimized by a genetic algorithm. The results show that the exergy loss of regenerators was reduced, and the entire exergy efficiency of the SPT plant was improved by configuring two high -temperature regenerators. The cycle performance of propane, serving as the second additive, becomes more significant when the cooling temperature is increased. The overall thermal efficiency of the CO2-propane-configured SPT plant is 2.08% higher than using CO2 alone at a condensation temperature of 50 degrees C. Meanwhile, the exergy efficiency of the SPT plant with CO2-propane cycle decreases less (1.67%) than CO2 (2.02%) when the condensation temperature rises from 42 degrees C to 50 degrees C. However, the temperature difference of the receiver would decrease when using CO2-propane. This study provides a valuable reference for the application of CO2-propane mixture in the dry-cooling Brayton cycle of the direct-heated SPT plant.
引用
收藏
页码:649 / 663
页数:15
相关论文
共 49 条
  • [1] An operation strategy and off-design performance for supercritical brayton cycle using CO2-propane mixture in a direct-heated solar power tower plant
    Ma, Ning
    Bu, Zhengkun
    Fu, Yanan
    Hong, Wenpeng
    Li, Haoran
    Niu, Xiaojuan
    [J]. ENERGY, 2023, 278
  • [2] CO2-based mixture working fluids used for the dry-cooling supercritical Brayton cycle: Thermodynamic evaluation
    Liu, Xinxin
    Xu, Zhen
    Xie, Yingchun
    Yang, Haiyang
    [J]. APPLIED THERMAL ENGINEERING, 2019, 162
  • [3] Thermodynamic analysis and comparison for different direct-heated supercritical CO2 Brayton cycles integrated into a solar thermal power tower system
    Zhu, Han-Hui
    Wang, Kun
    He, Ya-Ling
    [J]. ENERGY, 2017, 140 : 144 - 157
  • [4] A detailed model of direct dry-cooling for the supercritical carbon dioxide Brayton power cycle
    Lock, Andrew
    Hooman, Kamel
    Guan, Zhiqiang
    [J]. APPLIED THERMAL ENGINEERING, 2019, 163
  • [5] Dynamic characteristics of a direct-heated supercritical carbon-dioxide Brayton cycle in a solar thermal power plant
    Singh, Rajinesh
    Miller, Sarah A.
    Rowlands, Andrew S.
    Jacobs, Peter A.
    [J]. ENERGY, 2013, 50 : 194 - 204
  • [6] Viability Assessment of a Concentrated Solar Power Tower With a Supercritical CO2 Brayton Cycle Power Plant
    Alsagri, Ali Sulaiman
    Chiasson, Andrew
    Gadalla, Mohamed
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (05):
  • [7] Extremum-seeking control of a supercritical carbon-dioxide closed Brayton cycle in a direct-heated solar thermal power plant
    Singh, Rajinesh
    Kearney, Michael P.
    Manzie, Chris
    [J]. ENERGY, 2013, 60 : 380 - 387
  • [8] Proposal and Assessment of a Novel Multigeneration System Based On A Supercritical CO2 Brayton Cycle Driven by a Solar Power Tower Plant
    Mohammadi, Kasra
    Powell, Kody
    [J]. SOLARPACES 2020 - 26TH INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, 2022, 2445
  • [9] Comparison of direct and indirect natural draft dry cooling tower cooling of the sCO2 Brayton cycle for concentrated solar power plants
    Duniam, Sam
    Jahn, Ingo
    Hooman, Kamel
    Lu, Yuanshen
    Veeraragavan, Ananthanarayanan
    [J]. APPLIED THERMAL ENGINEERING, 2018, 130 : 1070 - 1080
  • [10] Effects of relative volume-ratios on dynamic performance of a direct-heated supercritical carbon-dioxide closed Brayton cycle in a solar-thermal power plant
    Singh, Rajinesh
    Rowlands, Andrew S.
    Miller, Sarah A.
    [J]. ENERGY, 2013, 55 : 1025 - 1032