Development and experimental verification of an active noise cancellation (ANC) method for non-invasive sensing

被引:1
|
作者
Zhuang, Bozhou [1 ]
Gencturk, Bora [1 ]
Asareh, Iman [2 ]
Oberai, Assad [2 ]
Ramaswamy, Harisankar [2 ]
Meyer, Ryan [3 ]
Good, Morris [3 ]
Taubman, Matthew [3 ]
机构
[1] Univ Southern Calif, Sonny Astani Dept Civil & Environm Engn, 3620 S Vermont Ave,KAP 210, Los Angeles, CA 90089 USA
[2] Univ Southern Calif, Dept Aerosp & Mech Engn, Los Angeles, CA 90089 USA
[3] Pacific Northwest Natl Lab, 902 Battelle Blvd, Richland, WA 99354 USA
关键词
Active noise cancellation (ANC); Non-invasive sensing; Ultrasonic testing; Signal-to-noise ratio (SNR); ALGORITHM; SIMULATION; EXTERIOR; STORAGE;
D O I
10.1016/j.ymssp.2023.110330
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Ultrasonic wave propagation may be used in non-invasive sensing to identify the properties of a fluid in a container. An ultrasonic excitation can be coupled into the liquid or the gas through the walls of the container and detected by a receiver on the other side. However, in addition to this fluid path, another signal will also propagate through the structure and is referred as noise in this study. For most materials, this structural noise will be of higher amplitude compared to the fluid signal due to the large acoustic impedance difference between the solid container and the fluid. In this paper, an active noise cancellation (ANC) method is developed and demonstrated on an experimental setup. It was shown that this method cancels more than 90% of the noise signal in a given time window of interest. A sequential version of this cancellation method is also proposed, and it was shown that its performance improves as the number of canceling excitations is increased. The performance was found to be independent of the location of canceling transducers and position of the silence window but dependent on the width of the silence window. As an example, the ANC method was applied to noise cancellation of a signal travelling through water in a stainless-steel container. The signal-to-noise ratio (SNR) of the water signal in the window of interest was increased by 148% from 13.98 dB to 34.68 dB by using the proposed ANC method.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing
    Min, Xiaolin
    Liu, Rong
    Fu, Bo
    Xu, Kexin
    [J]. OPTICS AND LASER TECHNOLOGY, 2017, 91 : 7 - 12
  • [2] EXPERIMENTAL THROMBOGENESIS BY NON-INVASIVE METHOD
    HAMER, JD
    MALONE, PC
    SILVER, IA
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1981, 315 (JUN): : P40 - P41
  • [3] EXPERIMENTAL THROMBOGENESIS BY A NON-INVASIVE, NON-TRAUMATIC METHOD
    HAMER, JD
    MALONE, PC
    SEVITT, S
    [J]. THROMBOSIS AND HAEMOSTASIS, 1981, 46 (01) : 311 - 311
  • [4] EXPERIMENTAL DEEP VENOUS THROMBOGENESIS BY A NON-INVASIVE METHOD
    HUME, M
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 1985, 67 (04) : 268 - 268
  • [5] EXPERIMENTAL DEEP VENOUS THROMBOGENESIS BY A NON-INVASIVE METHOD
    HAMER, JD
    MALONE, PC
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 1984, 66 (06) : 416 - 419
  • [6] Non-invasive imaging in experimental medicine for drug development
    Matthews, Paul M.
    Rabiner, Ilan
    Gunn, Roger
    [J]. CURRENT OPINION IN PHARMACOLOGY, 2011, 11 (05) : 501 - 507
  • [7] Non-invasive Optical Sensing Method Based on Random Lasing
    Tommasi, Federico
    Fini, Lorenzo
    Ignesti, Emilio
    Martelli, Fabrizio
    Cavalieri, Stefano
    [J]. 2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS-SPRING), 2019, : 219 - 222
  • [8] CARDIOGONIOMETRY - A NEW, NON-INVASIVE EXAMINATION METHOD FOR THE VERIFICATION OF MYOCARDIAL ISCHEMIA
    SANER, H
    SANZ, E
    BAUR, HR
    GURTNER, HP
    [J]. SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1982, 112 (45) : 1629 - 1629
  • [9] Development and Studying Value of Method of Non-Invasive Pulsometry
    Ryzhenko, Tetiana
    Dehtiaruk, Victor
    Budnyk, Vitalii
    Budnyk, Mykola
    Chaikovsky, Illya
    Sofienko, Sergiy
    [J]. 2019 IEEE 39TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2019, : 512 - 517
  • [10] Development of non-invasive method for assessment of hepatic steatosis
    Morikawa, H.
    Mano, K.
    Horinaka, H.
    Matsunaka, T.
    Matsumoto, Y.
    Ida, T.
    Kawaguchi, Y.
    Wada, K.
    Kawada, N.
    [J]. ULTRASONICS, 2016, 72 : 195 - 200