Guidewire replacement of valved tunneled-cuffed silicone catheters with power injectable polyurethane tunneled-cuffed catheters or with ports

被引:1
|
作者
Benvenuti, Stefano [1 ]
Finetti, Federico [2 ]
Porteri, Elena [1 ]
Ceresoli, Rosanna [1 ]
Pintossi, Cristian [1 ]
Zanatta, Francesca [1 ]
Bartolini, Gabriele [1 ]
Facchini, Federica [1 ]
Annovazzi, Caterina [1 ]
Alberti, Daniele [3 ,4 ]
机构
[1] ASST Spedali Civili, Vasc Access Unit, Ple Spedali Civili 1, I-25125 Brescia, Lombardia, Italy
[2] Univ Vita Salute San Raffaele, Milan, Lombardia, Italy
[3] Univ Brescia, ASST Spedali Civili Children Hosp, Dept Pediat Surg, Brescia, Lombardia, Italy
[4] Univ Brescia, Dept Clin & Expt Sci, Brescia, Lombardia, Italy
来源
JOURNAL OF VASCULAR ACCESS | 2025年 / 26卷 / 01期
关键词
Groshong; cuffed catheter; valved CVC; guidewire replacement; CENTRAL VENOUS CATHETERS; CHILDREN;
D O I
10.1177/11297298231218593
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Silicone Cuffed Centrally Inserted Central venous catheters (CICCs) were a type of catheters that have been used for a long time especially in cancer patients. Recently, thanks to biomedic research progresses, polyurethane catheters have resulted in higher surgical performances compared to classical silicone ones. Indeed, the inferior calibers of these new catheters lead to an extremely faster infusion rate. The presence of a valve at the tip of the catheter could suggest an impossible replacement procedure over a Seldinger guidewire. Method: The aim of this article is to explain our replacement technique over guidewire of silicone cuffed and valved tunneled CICCs with a power injectable polyurethane cuffed tunneled CICC. The casistic presented was evaluated at the Vascular Access Unit of ASST Spedali Civili in Brescia, Italy. The study involved 35 successful catheter replacement over guidewire, meanwhile cases where patients presented sepsis, exit site infection, or catheter damage were premeditatedly excluded. Results:The maneuver was always conducted following the same procedure without noticing particular complications associated with CICC insertion. Indeed, the operation was quick, feasible, and safe. Septic, thromboembolic, or hemorrhagic complications also related to patients presenting dysfunctional coagulation cascade were not encountered. Conclusions: Our experience regarding the replacement technique of silicone cuffed and valved catheters over guidewire was considered feasible, accurate, and efficient for all patients treated, even in those presenting thrombocytopenia or a dysfunctional coagulation cascade.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 50 条
  • [1] Management of bacteremia associated with tunneled-cuffed hemodialysis catheters
    Beathard, GA
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1999, 10 (05): : 1045 - 1049
  • [2] Complications of tunneled peripherally inserted and tunneled-cuffed central catheters in home parenteral nutrition
    Matysiak, Konrad
    Szewczuk, Magdalena
    Sobocki, Jacek
    Zdziarska, Marta
    Siatkowski, Idzi
    NUTRITION, 2021, 91-92
  • [3] Insertion of tunneled-cuffed hemodialysis catheters (TDC) and tunneled multi-lumen central venous catheters (CVC) as a combined procedure
    Saad, TF
    Duch, J
    Arun, M
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 244A - 244A
  • [4] Insertion of tunneled-cuffed Hemodialysis catheters (TDC) and tunneled multi-lumen central venous catheters (CVC) as a combined procedure
    Saad, TF
    Duch, J
    Arun, M
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 244A - 245A
  • [5] Thrombosis of Tunneled-Cuffed Hemodialysis Catheters: Treatment With High-Dose Urokinase Lock Therapy
    Donati, Gabriele
    Coli, Luigi
    Cianciolo, Giuseppe
    La Manna, Gaetano
    Cuna, Vania
    Montanari, Mara
    Gozzetti, Francesco
    Stefoni, Sergio
    ARTIFICIAL ORGANS, 2012, 36 (01) : 21 - 28
  • [6] Bloodstream infections and patient survival with tunneled-cuffed catheters for hemodialysis: A single-center observational study
    Donati, Gabriele
    Spazzoli, Alessandra
    Croci Chiocchini, Anna Laura
    Scrivo, Anna
    Bruno, Paolo
    Conte, Diletta
    Ruggeri, Marco
    Cappuccilli, Maria
    La Manna, Gaetano
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2020, 43 (12): : 767 - 773
  • [7] Pericardium catheterization using a tunneled-cuffed catheter for hemodialysis: A lesson
    Jin, Ji Zhe
    Piao, Shang Guo
    Li, Can
    JOURNAL OF VASCULAR ACCESS, 2024, 25 (02): : 691 - 692
  • [8] Bacteremia associated with tunneled, cuffed hemodialysis catheters
    Saad, TF
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 34 (06) : 1114 - 1124
  • [9] Clinical outcomes for femoral tunneled-cuffed hemodialysis catheters with different tip positions: A single-center retrospective study
    Wu, Sudan
    Zhang, Lifeng
    Wang, Qiqi
    Wei, Haijun
    Zheng, Siwei
    Huang, Dan
    Ni, Jie
    Liu, Yang
    JOURNAL OF VASCULAR ACCESS, 2024, 25 (06): : 1975 - 1981
  • [10] COMPLICATIONS ASSOCIATED WITH TUNNELED CUFFED DIALYSIS CATHETERS
    Saudan, P.
    Kissling, S.
    Triverio, P.
    Bourquin, V.
    Martin, R.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (07): : 605 - 605