Experimental investigation on bond behavior of CFRP-concrete interface with end anchorage in hygrothermal environments

被引:11
|
作者
Wang, Yilin [1 ]
Guo, Xinyan [2 ]
机构
[1] Univ Ghent, Dept Struct Engn & Bldg Mat, Magnel Vandepitte Lab, Technologiepk Zwijnaarde 60, B-9052 Ghent, Belgium
[2] South China Univ Technol, Sch Civil Engn & Transportat, Guangzhou 510640, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Carbon fiber reinforced polymer (CFRP); Hygrothermal environment; Bond behavior; End anchorage; Friction; STRENGTHENED RC BEAMS; FRP; SHEETS; PERFORMANCE;
D O I
10.1016/j.jobe.2023.106141
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Externally bonded reinforcement (EBR) of reinforced concrete (RC) structures with fiber reinforced polymer (FRP) is unable to meet the requirements of the engineering. Because premature debonding failure limits the usage scenario of the EBR method, which cannot fully utilize the high tensile performance of FRP. More and more studies focus on the improvement of the EBR method by extra anchors on the FRP-concrete interface to improve its ultimate strength. Considering the influence of environmental conditions on the FRP-concrete interface with anchorage, the application of extra anchorage under hygrothermal environments has to be investigated. The paper optimizes the existing end mechanical anchorage to avoid damage to carbon fiber reinforced polymer (CFRP) and concrete substrate. The compressive pressure exerted on the CFRP laminate can be controlled by adjusting the torque on the end anchorage. A series of end-anchoted doublelag shear tests under different hygrothermal conditions were carried out for invesitgating the bond behavior of CFRP-concrete interface. The test results showed that the load increment of the ultimate strength of the CFRP-concrete interface decreased with the increase in temperature and relative humidity. Correspondingly, friction surfaces due to the compression provided by end anchorage changed from concrete-concrete interface to the concrete-adhesive or adhesive-CFRP interfaces. The relationship between friction coefficient and temperature and relative humidity was built. The shear stress and slip distribution curves were calculated from the strain distribution functions fitted from the strain data measured by DIC. Fracture energy for the CFRP-concrete bond was estimated, and the bond-slip relationship for the hygrothermal conditions was constructed.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Analytical Model for Bond Behavior Prediction of CFRP-Concrete Joints with End Anchorage
    Dong, Kun
    Zhong, Caiqun
    Li, Peng
    Du, Derun
    POLYMERS, 2021, 13 (21)
  • [2] A probabilistic investigation into deterioration of CFRP-concrete interface in aggressive environments
    Kim, Yail J.
    Hossain, Mozahid
    Zhang, Jun
    CONSTRUCTION AND BUILDING MATERIALS, 2013, 41 : 49 - 59
  • [3] Study on Fatigue Bond Behavior of NSM CFRP-concrete Interface
    Chou J.-X.
    Zhang Z.-T.
    Zhang J.-R.
    Su M.
    Peng H.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2022, 35 (02): : 234 - 246
  • [4] Fatigue behavior of CFRP-concrete interface
    Huang, Pei-Yan
    Zheng, Xiao-Hong
    Zhou, Hao
    Guo, Xin-Yan
    Han, Qiang
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2012, 40 (10): : 184 - 189
  • [5] Experimental Study on Bond Strength of CFRP-concrete Interface in Sulfate Environment
    Liu S.
    Zhao J.
    Zhang J.
    Wang Z.
    Yang Z.
    Tiedao Xuebao/Journal of the China Railway Society, 2019, 41 (01): : 138 - 143
  • [6] Digital-image based performance analysis of CFRP-concrete interface bond under anchorage
    Zhao, Shaowei
    Han, Jinsong
    Guo, Rong
    Feng, Xinhao
    STRUCTURES, 2023, 58
  • [7] Effect of end anchorage on bond behavior of CFRP-to-concrete interface subjected to temperature variation
    Hao J.
    Dong K.
    Jiang J.
    Yang S.
    Du D.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2021, 53 (04): : 62 - 70
  • [8] Experimental and statistical dry-fracture assessment of the CFRP-concrete interface bond
    Boyajian, David
    Zirakian, Tadeh
    Boyajian, Christof
    Chen, Shen-En
    STRUCTURES, 2022, 36 : 580 - 588
  • [9] Bond performance model of concrete-to-CFRP interface with hybrid end anchorage
    Dong K.
    Yang Z.
    Jiang J.
    Jing F.
    Liu Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (02): : 178 - 186
  • [10] Bond behavior of fully bonded CFRP-concrete interface with improved double shear tests
    Li, Wen
    Huang, Peiyan
    Chen, Zhanbiao
    Zheng, Xiaohong
    Yang, Yi
    Guo, Xinyan
    JOURNAL OF BUILDING ENGINEERING, 2021, 43