共 31 条
Ultra-stretchable and conductive polyacrylamide/carboxymethyl chitosan composite hydrogels with low modulus and fast self-recoverability as flexible strain sensors
被引:18
|作者:
Ding, Hongyao
[1
]
Liu, Jie
[1
]
Huo, Peixian
[2
]
Ding, Rongjian
[1
]
Shen, Xiaodong
[1
]
Mao, Hongli
[1
]
Wen, Yuefang
[3
]
Li, Hui
[3
]
Wu, Zi Liang
[4
]
机构:
[1] Nanjing Tech Univ, Coll Mat Sci & Engn, Nanjing 210009, Peoples R China
[2] Univ Macau, Inst Appl Phys & Mat Engn, Joint Key Lab Minist Educ, Ave Univ, Taipa, Macau, Peoples R China
[3] Nanjing Tech Univ, Key Lab Light Weight Mat, Nanjing 210009, Peoples R China
[4] Zhejiang Univ, Dept Polymer Sci & Engn, MOE Key Lab Macromol Synth & Functionalizat, Hangzhou 310027, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Stretchable hydrogel;
Carboxymethyl chitosan;
Flexible sensors;
DOUBLE-NETWORK HYDROGEL;
HIGH TOUGHNESS;
NANOCOMPOSITE HYDROGELS;
PHYSICAL HYDROGELS;
FATIGUE;
TRANSPARENT;
SOFT;
D O I:
10.1016/j.ijbiomac.2023.127146
中图分类号:
Q5 [生物化学];
Q7 [分子生物学];
学科分类号:
071010 ;
081704 ;
摘要:
There is a great demand for the fabrication of soft electronics using hydrogels due to their biomimetic structures and good flexibility. However, conventional hydrogels have poor mechanical properties, which restricts their applications as stretchable sensors. Herein, a facile one-step strategy is proposed to fabricate tough and conductive hydrogels by making use of the graftability of carboxymethyl chitosan without extra conductive matter and crosslinking agent. The obtained polyacrylamide/carboxymethyl chitosan composite hydrogels possess outstanding transmittance and excellent mechanical performances, with tensile breaking stress of 630 kPa, breaking strain of 4560 %, toughness of 8490 kJ/m(3). These hydrogels have low modulus of 5-20 kPa, fast recoverability after unloading, high conductivity of similar to 0.85 S/m without the addition of other conductive substances and good biocompatibility. The ionic conductivity of the gels originates from the counterions of carboxymethyl chitosan, affording the hydrogels as resistive-type sensors. The resultant hydrogel sensors demonstrate a broad strain window (0.12-1500 %), excellent linear response, high sensitivity with the gauge factor reaching 11.72, and great durability, capable of monitoring diverse human motions. This work provides a new strategy to develop stretchable conductive hydrogels with promising applications in the fields of artificial intelligence and flexible electronics.
引用
收藏
页数:10
相关论文