4D-CT as a second line preoperative localization test for the evaluation of primary hyperparathyroidism

被引:0
|
作者
Barranquero, Alberto G. [1 ]
Pastor, Paula [2 ]
Ortega, Ana [2 ]
Corral, Sara [3 ]
Ramirez, Joaquin Gomez [4 ]
Luengo, Patricia [3 ]
Porrero, Belen [3 ]
Cabanas, Luis Jacobo [3 ]
机构
[1] Hosp Arnau Vilanova, Serv Cirugia Gen & Aparato Digest, Lleida, Spain
[2] Hosp Univ Ramon y Cajal, Serv Cirugia Gen & Aparato Digest, Madrid, Spain
[3] Hosp Univ Ramon y Cajal Madrid, Serv Cirugia Gen & Aparato Digest, Secc Cirugia Endocrina Mama Sarcoma & Melanoma, Madrid, Spain
[4] Hosp Univ La Paz, Serv Cirugia Gen & Aparato Digest, Unidad Cirugia Endocrina & Cirugia Mama, Madrid, Spain
来源
CIRUGIA ESPANOLA | 2023年 / 101卷 / 08期
关键词
Four-dimensional computed; tomography; Sensitivity and specificity; Primary hyperparathyroidism; Surgery; Parathyroidectomy; HYPERFUNCTIONING PARATHYROID-GLANDS; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; GUIDELINES; SESTAMIBI; ACCURACY; SCINTIGRAPHY; EXPLORATION; MANAGEMENT; STATEMENT; ADENOMA;
D O I
10.1016/j.ciresp.2022.06.007
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Four-dimensional computerized tomography (4D-CT) offers a good sensitivity for the localization of the pathological gland responsible of primary hyperparathyroidism. The aim was to evaluate its results as a second line preoperative localization test after inconclusive or discordant results of usual preoperative studies.Material and methods: Observational retrospective study that included all patients inter-vened for primary hyperparathyroidism with 4D-CT scan as preoperative study, from 1st October 2016 to 1st October 2021, in a tertiary referral centre.The results of 4D-CT, cervical ultrasound, and nuclear medicine explorations (scintigra-phy, SPECT and SPECT-CT) were compared with the gold standard of the surgical exploration and the pathological result. The correct lateralization and the approximate localization rates of the pathological gland were evaluated.Results: A total of 64 patients were analysed, with a 93,8% (60/64) remission rate. 4D-CT showed a correct lateralization in 57,8% (37/64) of the cases and revealed the approximate localization of the gland in 48,4% (31/64) of the cases. The cervical ultrasound had a rate of 31,1% (19/61) and 18% (11/61) for the correct lateralization and approximate localization, respectively, compared to 34,9% (22/63) and 28,6% (18/63) in nuclear medicine explorations, and 32,7% (16/49) and 24,5% (12/49) in SPECT-CT. These differences were statistically significant.Conclusion: 4D-CT demonstrated acceptable results for the localization of the lesions re-sponsible of primary hyperparathyroidism, thus its use should be considered with the absence of localization in routinely studies.(C) 2022 AEC. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:530 / 537
页数:8
相关论文
共 50 条
  • [1] Preoperative localization of hyperfunctioning parathyroid glands with 4D-CT
    Lundstroem, Anke Katrin
    Trolle, Waldemar
    Soerensen, Christian Hjort
    Myschetzky, Peter Sand
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (05) : 1253 - 1259
  • [2] Preoperative localization of hyperfunctioning parathyroid glands with 4D-CT
    Anke Katrin Lundstroem
    Waldemar Trolle
    Christian Hjort Soerensen
    Peter Sand Myschetzky
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 1253 - 1259
  • [3] Preoperative Modified 4D-CT Reduces Unnecessary Opposite Side Exploration in Patients with Primary Hyperparathyroidism
    Singla, S.
    Thirunavukarasu, P.
    Kukar, M.
    Platz, T.
    Kumar, S.
    Cance, W. G.
    ANNALS OF SURGICAL ONCOLOGY, 2014, 21 : S91 - S92
  • [4] 18F-Fluorocholine PET and Multiphase CT Integrated in Dual Modality PET/4D-CT for Preoperative Evaluation of Primary Hyperparathyroidism
    Pretet, Valentin
    Rotania, Marianela
    Helali, Mehdi
    Ignat, Mihaela
    Vix, Michel
    Imperiale, Alessio
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (06)
  • [5] The Role of 4D-CT for Pre-Operative Localization in Patients with Primary Hyperparathyroidism with Negative Ultrasonography and/or Sestamibi SPECT/CT
    Yanar, Ceylan
    Kostek, Mehmet
    Unlu, Mehmet Taner
    Caliskan, Ozan
    Dincer, Burak
    Cetinoglu, Isik
    Aygun, Nurcihan
    Ozel, Alper
    Gemalmaz, Ali
    Uludag, Mehmet
    MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL, 2023, 57 (02): : 238 - 244
  • [6] [18F]F-Choline PET/CT and 4D-CT in the evaluation of primary hyperparathyroidism: rivals or allies?
    Fiz, Francesco
    Bottoni, Gianluca
    Massollo, Michela
    Trimboli, Pierpaolo
    Catrambone, Ugo
    Bacigalupo, Lorenzo
    Righi, Sergio
    Treglia, Giorgio
    Imperiale, Alessio
    Piccardo, Arnoldo
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 67 (02): : 130 - 137
  • [7] Efficacy of 4D-CT preoperative localization in 2 patients with MEN 2A
    Philip, Maria
    Guerrero, Marlon A.
    Evans, Douglas B.
    Hunter, George J.
    Edeiken-Monroe, Beth S.
    Vu, Thinh
    Perrier, Nancy D.
    JOURNAL OF SURGICAL EDUCATION, 2008, 65 (03) : 182 - 185
  • [8] Parathyroid Gland Localization in Primary Hyperparathyroidism: Evaluation of a Novel Imaging Protocol and Direct Head-to-Head Comparison of Parathyroid 4D-CT and Sestamibi SPECT/CT
    Yeh, Randy
    Tay, Yu-Kwang Donovan
    Tabacco, Gaia
    Dercle, Laurent
    Kuo, Jennifer
    Bandeira, Leonardo
    Mcmanus, Catherine
    Lee, James
    Bilezikian, John
    JOURNAL OF BONE AND MINERAL RESEARCH, 2018, 33 : 63 - 64
  • [9] Preoperative 4D CT Scan Facilitates Localization of Small and Ectopic Parathyroid Adenomas in Primary Hyperparathyroidism
    Matar, Regina
    Jackson, Katherine
    Wright, Michael
    Cotsalas, Deanna
    Hobbs, Susan
    Kaproth-Joslin, Katherine
    Moalem, Jacob
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2021, 233 (05) : S67 - S68
  • [10] The Utility of 4D-CT Imaging in Primary Hyperparathyroidism Management in a Low-Volume Center
    Murruste, Marko
    Kivilo, Martin
    Kase, Karri
    Kirsimagi, Ulle
    Tahepold, Annika
    Tammiksaar, Kaia
    MEDICINA-LITHUANIA, 2023, 59 (08):