Comparison of speech perception in bimodal cochlear implant patients with respect to the cochlear coverage

被引:0
|
作者
Rader, Tobias [1 ,5 ]
Schrank, Leonhard [1 ]
Spiegel, Jennifer L. [2 ,3 ]
Nachtigaeller, Pascal [1 ]
Spiro, Judith E. [4 ]
Hempel, John-Martin [2 ]
Canis, Martin [2 ]
Mueller, Joachim [2 ]
机构
[1] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Otorhinolaryngol, Div Audiol, Munich, Germany
[2] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Otorhinolaryngol, Munich, Germany
[3] Ludwig Maximilians Univ Munchen, German Ctr Vertigo & Balance Disorders, Munich, Germany
[4] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Radiol, Munich, Germany
[5] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Otorhinolaryngol, Div Audiol, Marchioninistr 15, D-81377 Munich, Germany
关键词
Hearing aids; Prostheses and implants; Computed tomography; Speech intelligibility; Speech audiometry; ELECTRIC-ACOUSTIC STIMULATION; SINGLE-SIDED DEAFNESS; INSERTION DEPTH; HEARING; ADULTS; PERFORMANCE; RECOGNITION; POSITION; OUTCOMES; NOISE;
D O I
10.1007/s00106-023-01327-5
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
BackgroundThe hearing success of patients with bimodal fitting, utilizing both a cochlear implant (CI) and a hearing aid (HA), varies considerably: While some patients benefit from bimodal CI and HA, others do not.ObjectivesThis retrospective study aimed to investigate speech perception in bimodally fitted patients and compare it with the cochlear coverage (CC).MethodsThe CC was calculated with the OTOPLAN software, measuring the cochlear duct length on temporal bone CT scans of 39 patients retrospectively. The patients were categorized into two groups: CC & LE; 65% (CC500) and CC > 65% (CC600). Monaural speech intelligibility for monosyllables at a sound pressure level (SPL) of 65 dB in a free-field setting was assessed before and after CI at various time points. The two groups, one with preoperative HA and one with postoperative CI, were compared. Additionally, speech intelligibility was correlated with CC in the entire cohort before CI and at the last available follow-up (last observation time, LOT).ResultsOverall, there was no significant difference in speech intelligibility between CC500 and CC600 patients, with both groups demonstrating a consistent improvement after implantation. While CC600 patients tended to exhibit earlier improvement in speech intelligibility, CC500 patients showed a slower initial improvement within the first 3 months but demonstrated a steeper learning curve thereafter. At LOT, the two patient groups converged, with no significant differences in expected speech intelligibility. There was no significant relationship between unimodal/unilateral free-field speech intelligibility and CC. Interestingly, patients with a CC of 70-75% achieved the highest speech intelligibility.ConclusionDespite of the lack of a significant correlation between CC and speech perception, patients appeared to reach their maximum in unimodal/unilateral speech perception primarily at a coverage level of 70-75%. Nevertheless, further investigation is warranted, as CC500 was associated with shorter cochlear duct length, and different types of electrodes were used in both groups.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [1] Comparison of speech perception in bimodal cochlear implant patients with respect to the cochlear coverage
    Tobias Rader
    Leonhard Schrank
    Jennifer L. Spiegel
    Pascal Nachtigäller
    Judith E. Spiro
    John-Martin Hempel
    Martin Canis
    Joachim Mueller
    [J]. HNO, 2024, 72 : 17 - 24
  • [2] Perception of Sung Speech in Bimodal Cochlear Implant Users
    Crew, Joseph D.
    Galvin, John J., III
    Fu, Qian-Jie
    [J]. TRENDS IN HEARING, 2016, 20
  • [3] Speech perception as a function of cochlear coverage-comparison in bimodally hearing cochlear implant patients. German version
    Rader, Tobias
    Schrank, Leonhard
    Spiegel, Jennifer L. L.
    Nachtigaeller, Pascal
    Spiro, Judith E. E.
    Hempel, John-Martin
    Canis, Martin
    Mueller, Joachim
    [J]. HNO, 2023, 71 (08) : 504 - 512
  • [4] The Effect of Cochlear Coverage on Auditory and Speech Performance in Cochlear Implant Patients
    Doubi, Aseel
    Almuhawas, Fida
    Alzhrani, Farid
    Doubi, Motaz
    Aljutaili, Hamad
    Hagr, Abdulrahman
    [J]. OTOLOGY & NEUROTOLOGY, 2019, 40 (05) : 602 - 607
  • [5] The speech perception gap in cochlear implant patients
    Franks, Zechariah G.
    Jacob, Abraham
    [J]. COCHLEAR IMPLANTS INTERNATIONAL, 2019, 20 (04) : 176 - 181
  • [6] Bimodal speech perception in infant hearing aid and cochlear implant users
    Barker, BA
    Tomblin, JB
    [J]. ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2004, 130 (05) : 582 - 586
  • [7] Timbre and Speech Perception in Bimodal and Bilateral Cochlear-Implant Listeners
    Kong, Ying-Yee
    Mullangi, Ala
    Marozeau, Jeremy
    [J]. EAR AND HEARING, 2012, 33 (05): : 645 - 659
  • [8] Comparison of speech perception between monaural and binaural hearing in cochlear implant patients
    Iwaki, T
    Matsushiro, N
    Mah, SR
    Sato, T
    Yasuoka, E
    Yamamoto, KI
    Kubo, T
    [J]. ACTA OTO-LARYNGOLOGICA, 2004, 124 (04) : 358 - 362
  • [9] Sound Localization and Speech Perception in Noise of Pediatric Cochlear Implant Recipients: Bimodal Fitting Versus Bilateral Cochlear Implants
    Choi, Ji Eun
    Moon, Il Joon
    Kim, Eun Yeon
    Park, Hee-Sung
    Kim, Byung Kil
    Chung, Won-Ho
    Cho, Yang-Sun
    Brown, Carolyn J.
    Hong, Sung Hwa
    [J]. EAR AND HEARING, 2017, 38 (04): : 426 - 440
  • [10] Cochlear Blood Flow and Speech Perception Ability in Cochlear Implant Users
    Nakashima, Tsutomu
    Hattori, Taku
    Sone, Michihiko
    Asahi, Kiyomitsu
    Matsuda, Naoko
    Teranishi, Masaaki
    Yoshida, Tadao
    Kato, Ken
    Sato, Eisuke
    [J]. OTOLOGY & NEUROTOLOGY, 2012, 33 (02) : 165 - 168