Comparison of Three Glomerular Filtration Rate Estimating Equations with 24-Hour Urine Creatinine Clearance Measurement in Potential Living Kidney Donors

被引:0
|
作者
Giron-Luque, Fernando [1 ]
Garcia-Lopez, Andrea [2 ]
Baez-Suarez, Yenny [1 ]
Patino-Jaramillo, Nasly [2 ]
机构
[1] Colombiana Trasplantes, Dept Transplant Surg, Bogota, Colombia
[2] Colombiana Trasplantes, Dept Transplant Res, Bogota, Colombia
关键词
CKD-EPI; GFR ESTIMATION; SERUM CREATININE; COCKCROFT-GAULT; MDRD; PREDICTION; ACCURACY; DISEASE; ADULTS; PERFORMANCE;
D O I
10.1155/2023/2022641
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background. The accuracy of the measurement of renal function in potential living kidney donors (PLKD) is essential. The direct measurement of glomerular filtration rate (mGFR) has been considered the "gold standard." The estimated GFR (eGFR) with 24-hour urinary creatinine clearance (CrCl) is frequently used because of its availability. We aim to evaluate the correlation and agreement of eGFR using serum-based creatinine formulas (Cockcroft-Gault, MDRD, and CKD-EPI) and the eGFR based on 24-hour urinary CrCl to evaluate kidney function in PLKD. Methods. We evaluated the kidney function in 799 PLKD using 24-hour urinary CrCl method and compared the correlation and agreement with the eGFR based on creatinine formulas (Cockcroft-Gault, MDRD, and CKD-EPI). We calculated the mean bias (difference), precision (SD of this difference), accuracy, and performed Bland-Altman plots. Results. A total of 799 PLKD were analyzed. The age of the PLKD ranged from 18 to 73 years. Weak to mild correlation was observed between 24-hour urinary CrCl and all formulas (ranged from 0.31 to 0.49). The three equations underestimated the GFR. Using the Bland-Altman graphic, we observed that the CKD-EPI was the least scattered and most precise; however, mean bias and the interval range (limits of agreement) of all formulas were too big to assume equivalence between 24-hour urinary CrCl method and eGFR based on creatinine. Results of mean bias were similar when comparing the three equations in patients with CrCl GFR <60. However, the accuracy of all formulas was better for the female group and the youngest individuals (& LE;40 years old). Conclusion. In this PLKD cohort, of all the three equations, the CKD-EPI was the least scattered and most precise. However, the correlation and the level of agreement between the three equations and 24-hour urinary CrCl were too low to assume the equivalence.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Comparison of Three Glomerular Filtration Rate Estimating Equations With 24-Hour Urine Creatinine Clearance Measurement in Live Kidney Donors
    Giron Luque, Fernando
    Garcia Lopez, Andrea
    Patino Jaramillo, Nasly
    [J]. TRANSPLANTATION, 2022, 106 (09) : S606 - S606
  • [2] COMPARISON OF PERFORMANCE OF VARIOUS ESTIMATED GLOMERULAR FILTRATION RATE EQUATIONS WITH MEASURED CREATININE CLEARANCE FROM 24-HOUR URINE
    Lim, Chun Soo
    Hwang, Jin Ho
    Chin, Ho Jun
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34
  • [3] Concordance of glomerular filtration rate with creatinine clearance in 24-hour urine and Schwartz and Schwartz updated
    Luisa Salazar-Gutierrez, Maria
    Ochoa-Ponce, Cristina
    Carlos Lona-Reyes, Juan
    Ivonne Gutierrez-Iniguez, Sara
    [J]. BOLETIN MEDICO DEL HOSPITAL INFANTIL DE MEXICO, 2016, 73 (03): : 181 - 187
  • [4] A comparison of prediction equations for estimating glomerular filtration rate in Chinese potential living kidney donors
    Zhao, Wen-Yu
    Zeng, Li
    Zhu, You-Hua
    Wang, Li-Ming
    Zhou, Mei-Sheng
    Han, Shu
    Zhang, Lei
    [J]. CLINICAL TRANSPLANTATION, 2009, 23 (04) : 469 - 475
  • [5] COMPARISON OF MEASURED GLOMERULAR FILTRATION RATE USING 24-HOUR URINE CREATININE CLEARANCE WITH 51-CHROMIUM EDTA IN A MALAYSIAN COHORT OF LIVING KIDNEY DONOR CANDIDATES
    Thye, Chee Keong
    Lee, Yee Wan
    Jalalonmuhali, Maisarah
    Lim, Soo Kun
    Ng, Kok Peng
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 2035 - 2035
  • [6] Timed Creatinine Clearance and Measured Glomerular Filtration Rate in Living Kidney Donors
    Husain, S. Ali
    Stevens, Jacob S.
    King, Kristen L.
    Robbins-Juarez, Shelief Y.
    Cohen, Matthew
    Lyashchenko, Alexander K.
    Cremers, Serge
    Mohan, Sumit
    [J]. KIDNEY MEDICINE, 2023, 5 (01)
  • [7] Concordance in critical patients between the equations designed for the calculation of glomerular filtration rate and 24-hour creatinine clearance
    Seller-Perez, G.
    Herrera-Gutierrez, M. E.
    Banderas-Bravo, E.
    Olalla-Sanchez, R.
    Lozano-Saez, R.
    Quesada-Garcia, G.
    [J]. MEDICINA INTENSIVA, 2010, 34 (05) : 294 - 302
  • [8] 24-Hour Creatinine Clearance Reliability for Estimation of Glomerular Filtration Rate in Different Stages of Chronic Kidney Disease
    El-Minshawy, Osama
    Saber, Rafet A.
    Osman, Ashraf
    [J]. SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2010, 21 (04) : 686 - 693
  • [9] Accuracy of GFR estimation formula in determination of glomerular filtration rate in kidney donors: Comparison with 24 h urine creatinine clearance
    Hafeez, Abdul Rauf
    Idrees, Muhammad Khalid
    Akhtar, Syed Fazal
    [J]. SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2016, 27 (02) : 320 - 325
  • [10] Comparison of 24-hour urinary creatinine clearance and estimated glomerular filtration rate based on a panel of filtration markers in patients with chronic kidney disease
    Iversen, Esben
    Boesby, Lene
    Hansen, Ditte
    Houlind, Morten Baltzer
    [J]. PHARMACOLOGY RESEARCH & PERSPECTIVES, 2022, 10 (05):