Effect of aortic curvature on bioprosthetic aortic valve performance

被引:3
|
作者
Vogl, Brennan [1 ]
Gadhave, Rajat [1 ]
Wang, Zhenyu [2 ,3 ]
El Shaer, Ahmed [4 ]
Ponce, Alejandra Chavez [4 ]
Alkhouli, Mohamad [4 ]
Hatoum, Hoda [1 ,5 ]
机构
[1] Michigan Technol Univ, Dept Biomed Engn, Houghton, MI 49931 USA
[2] Ohio State Univ, Dept Mech Engn, Columbus, OH USA
[3] Ohio State Univ, Simulat Innovat & Modeling Ctr, Columbus, OH USA
[4] Mayo Clin, Dept Cardiovasc Med, Rochester, MN USA
[5] Michigan Technol Univ, Hlth Res Inst, Inst Comp & Cybernet, Ctr Biocomp & Digital Hlth, Houghton, MI USA
关键词
Aortic valve; Bioprosthetic valve; Aortic curvature; Pressure gradient; Pressure recovery; PRESSURE RECOVERY; DOPPLER ULTRASOUND; CATHETER GRADIENTS; STENOSIS; IMPACT; OVERESTIMATION; MANIFESTATION; REPLACEMENT; TRENDS; AREA;
D O I
10.1016/j.jbiomech.2022.111422
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Transvalvular pressure gradient (AP) after aortic valve replacement is an important surrogate of aortic bio-prostheses performance. Invasive AP is often measured after transcatheter aortic valve replacement to exclude patient-prosthetic mismatch. However, invasive aortic pressures are usually recorded in the pressure recovery (PR) zone downstream of the valve, potentially resulting in AP underestimation compared to noninvasive measurements. PR was extensively studied in straight ascending aortas. However, the impact of various aortic arch configurations on AP has not been explored. PR was assessed in a pulse duplicating simulator at various cardiac conditions of cardiac output, heart rates and pressures. Three different aortic geometries with identical root dimensions but with different aortic arches were used: (1) curvature 1, (2) curvature 2, and (3) straight aortic models. Instantaneous pressure and peak AP measurements were recorded incrementally along the models for each cardiac condition. The models with aortic arches produced two distinct PR zones (after the valve and after the aortic arch), whereas the model without an aortic arch produced only one PR zone (after the valve). The trend of the pressure and AP curves for each model was independent of the cardiac condition used, but the individually measured pressure magnitudes did change with different conditions. In this study, we illustrated the differences in PR between distinct aortic curvatures and straight aorta. PR affects pressure and AP measurements. These effects are clear when recording aortic pressures by catheterization and echocardiography.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Effect of statins on the progression of bioprosthetic aortic valve degeneration
    Antonini-Canterin, F
    Zuppiroli, A
    Popescu, BA
    Granata, G
    Cervesato, E
    Piazza, R
    Pavan, D
    Nicolosi, GL
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (12): : 1479 - 1482
  • [2] Bioprosthetic aortic valve durability in the era of transcatheter aortic valve implantation
    Salaun, Erwan
    Clavel, Marie-Annick
    Rodes-Capau, Josep
    Pibarot, Philippe
    HEART, 2018, 104 (16) : 1323 - 1332
  • [3] The place of a stentless aortic bioprosthetic valve
    Correia, Pedro M.
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2018, 37 (10) : 819 - 820
  • [4] Determinants of Bioprosthetic Aortic Valve Degeneration
    Nitsche, Christian
    Kammerlander, Andreas A.
    Knechtelsdorfer, Klaus
    Kraiger, Jakob A.
    Goliasch, Georg
    Dona, Carolina
    Schachner, Laurin
    Oeztuerk, Beguem
    Binder, Christina
    Duca, Franz
    Aschauer, Stefan
    Zimpfer, Daniel
    Bonderman, Diana
    Hengstenberg, Christian
    Mascherbauer, Julia
    JACC-CARDIOVASCULAR IMAGING, 2020, 13 (02) : 345 - 353
  • [5] Bioprosthetic Aortic Valve Infective Endocarditis
    Rodriguez, Joleen Duarte
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2009, 25 (02) : 116 - 120
  • [6] A notion of bioprosthetic aortic valve durability
    Thyregod, Hans Gustav Horsted
    De Backer, Ole
    Sondergaard, Lars
    EUROPEAN HEART JOURNAL, 2024,
  • [7] Transcatheter Aortic Valve Replacement for Bioprosthetic Aortic Valve Failure The Valve-in-Valve Procedure
    Webb, John G.
    Dvir, Danny
    CIRCULATION, 2013, 127 (25) : 2542 - 2550
  • [8] Valve-in-Valve Transcatheter Aortic Valve Replacement in Failed Trifecta Bioprosthetic Aortic Valve
    Zmaili, Mohammad
    Spilias, Nikolaos
    Ramu, Shivabalan Kathavarayan
    Prasad, Rohan
    Abushouk, Abdelrahman
    Harb, Serge
    Puri, Rishi
    Reed, Grant
    Yun, James
    Krishnaswamy, Amar
    Kapadia, Samir
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B285 - B286
  • [9] Valve in valve percutaneous aortic valve implantation for severe mixed bioprosthetic aortic valve disease
    De Vroey, Frederic
    Legget, Malcolm
    Ormiston, John
    Webster, Mark
    Stewart, James
    NEW ZEALAND MEDICAL JOURNAL, 2012, 125 (1353) : 146 - 148
  • [10] Outcomes of surgical bioprosthetic aortic valve replacement for aortic insufficiency
    Danial, Pichoy
    Girdauskas, Evaldas
    Aissani, Anissa
    Debauchez, Matthieu
    Lebreton, Guillaume
    Leprince, Pascal
    Reichenspurner, Hermann
    Petersen, Johannes
    Lansac, Emmanuel
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2022, 115 (11) : 588 - 597