The walls of the femoral neck as an auxiliary tool for femoral stem positioning

被引:0
|
作者
Morgan, Samuel [1 ]
Sadovnic, Ofer [2 ]
Iluz, Moshe [2 ]
Garceau, Simon [3 ]
Amzallag, Nisan [4 ]
Krasin, Elisha [4 ]
Lichtenstein, Adi [4 ]
Warschawski, Yaniv [4 ]
机构
[1] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Tel Aviv Dist, Israel
[2] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Div Radiol, Tel Aviv, Tel Aviv Dist, Israel
[3] NYU, NYU Langone, Div Orthopaed Adult Joint Reconstruct, New York, NY 10003 USA
[4] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Div Orthopaed, Tel Aviv, Tel Aviv Dist, Israel
关键词
Femoral anteversion; femoral neck; total hip arthroplasty; TOTAL HIP-ARTHROPLASTY; ANTEVERSION; NAVIGATION; CT;
D O I
10.1177/11207000211040763
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Femoral anteversion is a major contributor to functionality of the hip joint and is implicated in many joint pathologies. Accurate determination of component version intraoperatively is a technically challenging process that relies on the visual estimation of the surgeon. The following study aimed to examine whether the walls of the femoral neck can be used as appropriate landmarks to ensure appropriate femoral prosthesis version intraoperatively. Methods: We conducted a retrospective study based on 32 patients (64 hips) admitted to our centre between July and September 2020 who had undergone a CT scan of their lower limbs. Through radiological imaging analysis, the following measurements were performed bilaterally for each patient: anterior wall version, posterior wall version, and mid-neck femoral version. Anterior and posterior wall version were compared and evaluated relative to mid-neck version, which represented the true version value. Results: Mean anterior wall anteversion was 20 degrees (95% CI, 17.6-22.8 degrees) and mean posterior wall anteversion was -12 degrees (95% CI, -15 to -9.7 degrees). The anterior walls of the femoral neck had a constant of -7 and a coefficient of 0.9 (95% CI, -9.8 to -4.2; p < 0.0001; R-2 0.77). The posterior walls of the femoral neck had a constant of 20 and a coefficient of 0.7 (95% CI, 17.8-22.5; p < 0.0001; R-2 0.60). Conclusions: Surgeons can accurately obtain femoral anteversion by subtracting 7 degrees from the angle taken between the anterior wall and the posterior femoral condyles or by adding 20 degrees to the angle taken between the posterior wall and the posterior femoral condyles.
引用
收藏
页码:241 / 246
页数:6
相关论文
共 50 条
  • [1] Utility of Preoperative Femoral Neck Geometry in Predicting Femoral Stem Anteversion
    Park, Kwan Kyu
    Tsai, Tsung-Yuan
    Dimitriou, Dimitris
    Kwon, Young-Min
    JOURNAL OF ARTHROPLASTY, 2015, 30 (06): : 1079 - 1084
  • [2] Femoral Neck Cut Level Affects Positioning of Modular Short-Stem Implant
    Mihalko, William M.
    Saleh, Khaled J.
    Heller, Markus O.
    Mollard, Benoit
    Koenig, Christian
    Kammerzell, Sergej
    ORTHOPEDICS, 2009, 32 (10) : 18 - 21
  • [3] IMPROVED POSITIONING OF THE FEMORAL STEM WITH A CENTRALIZING DEVICE
    EGUND, N
    LIDGREN, L
    ONNERFALT, R
    ACTA ORTHOPAEDICA SCANDINAVICA, 1990, 61 (03): : 236 - 239
  • [4] A device to aid in positioning for lateral roentgenograms of the femoral neck
    Koven, MI
    Epstein, BS
    Kulick, M
    AMERICAN JOURNAL OF ROENTGENOLOGY AND RADIUM THERAPY, 1942, 48 : 554 - 556
  • [5] Posterior fully threaded positioning screw prevents femoral neck collapse in Garden I or II femoral neck fractures
    Shin, Kyun-Ho
    Hong, Seok-Ha
    Han, Seung-Beom
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (04): : 1031 - 1037
  • [6] CT measurement of anteversion in the femoral neck - The influence of femur positioning
    Hermann, KL
    Egund, N
    ACTA RADIOLOGICA, 1997, 38 (04) : 527 - 532
  • [7] Femoral neck prosthesis in the case of femoral neck fracture and ipsilateral long stem-knee tumour prosthesis
    Eichinger, S
    Forst, R
    UNFALLCHIRURG, 2005, 108 (08): : 679 - 683
  • [8] Comparison of Bone Preservation in Elderly Patients with Femoral Neck Fracture After Bipolar Hemiarthroplasty Using Shorter Femoral Stem and Standard Femoral Stem
    Lim, Jae-Young
    Park, Hyeong-Jun
    Lee, Young-Kyun
    Ha, Yong-Chan
    Koo, Kyung-Hoi
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (06) : 868 - 878
  • [9] Comparison of Bone Preservation in Elderly Patients with Femoral Neck Fracture After Bipolar Hemiarthroplasty Using Shorter Femoral Stem and Standard Femoral Stem
    Jae-Young Lim
    Hyeong-Jun Park
    Young-Kyun Lee
    Yong-Chan Ha
    Kyung-Hoi Koo
    Indian Journal of Orthopaedics, 2020, 54 : 868 - 878
  • [10] Clinical application of the Femoral Neck System in femoral neck fractures
    Zeng, Hao
    Yuan, Xiaobo
    Xiang, Bo
    Zheng, Maowen
    ASIAN JOURNAL OF SURGERY, 2023, 46 (11) : 4885 - 4886