His bundle pacing and left bundle branch area pacing: Feasibility and safety

被引:0
|
作者
Saleiro, Carolina [1 ]
Sousa, Pedro A. [1 ]
Nogueira, Catarina [2 ]
Mota, Lidia [2 ]
Almeida, Claudia [2 ]
Braganca, Gisela [2 ]
Paisana, Francisco [2 ]
机构
[1] Ctr Hosp & Univ Coimbra, Serv Cardiol, Coimbra, Portugal
[2] Unidade Local Saude Castelo Branco, Serv Cardiol, Castelo Branco, Portugal
关键词
His bundle pacing; Left bundle branch area pacing; Physiological pacing; CARDIAC RESYNCHRONIZATION THERAPY; ATRIAL;
D O I
10.1016/j.repc.2022.10.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: There has been increasing interest in pacing methods that provide physiological stimulation, such as His bundle pacing (HBP) or left bundle branch area pacing (LBBAP). Our goal was to assess the feasibility and safety of these techniques.Methods: Prospective observational single-center study evaluating 46 patients with indication for a pacemaker that attempted HBP or LBBAP from July 2020 to November 2021. Procedural endpoints and pacing parameters were assessed and compared at implantation and three-month follow-up.Results: Overall acute procedural success was achieved in 96% of the cases. Successful HBP was achieved in 91% of the patients and all patients for LBBAP. During implantation, HBP patients presented a higher capture threshold (0.80 [0.55-1.53] V vs. 0.70 [0.40-0.90] V, p=0.08) and lower R-wave amplitude (4.0 [2.9--6.2] mV vs. 7.8 [5.5-10.5] mV, p=0.001) compared to LBBAP patients. There was no difference between groups, either acutely or at 3-months, regarding paced QRS duration (125 & PLUSMN;22 ms vs. 133 & PLUSMN;16 ms, p=0.08; 118 & PLUSMN;16 ms vs. 124 & PLUSMN;14 ms, p=0.19). Although procedural time was similar with both techniques (95 [75-139] min vs. 95 [74-116] min, p=0.79), fluoroscopy time was significantly reduced during LBBAP (8.1 [5.3-13.4] min vs. 4.1 [3.1-11.3] min, p=0.05). At 3 months of follow-up, the pacing threshold remained with a stable profile in HBP as in LBBAP (1.25 [0.75-2.00] V, p=0.09 and 0.60 [0.50-0.80] V, p=0.78), respectively. The need for re-intervention occurred in 3 (6.5%) HBP cases during follow-up.Conclusion: This first national study demonstrates the feasibility and safety of the HBP and LBBAP in patients with pacemaker indication.& COPY; 2023 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espan & SIM;a, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:683 / 691
页数:9
相关论文
共 50 条
  • [1] Feasibility of His bundle pacing and atrioventricular junction ablation with left bundle branch area pacing as backup
    Mahajan, Ankit
    Trivedi, Rohan
    Subzposh, Faiz A.
    Vijayaraman, Pugazhendhi
    [J]. HEART RHYTHM, 2024, 21 (07) : 1180 - 1181
  • [2] Clinical outcomes of left bundle branch area pacing compared to His bundle pacing
    Vijayaraman, Pugazhendhi
    Rajakumar, Clement
    Naperkowski, Angela M.
    Subzposh, Faiz A.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (06) : 1234 - 1243
  • [3] CLINICAL OUTCOMES OF LEFT BUNDLE BRANCH AREA PACING COMPARED TO HIS BUNDLE PACING
    Rajakumar, Clement
    Naperkowski, Angela
    Subzposh, Faiz Ali
    Vijayaraman, Pugazhendi
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 40 - 40
  • [4] His bundle and left bundle branch pacing
    Israel, Carsten W.
    [J]. HERZ, 2021, 46 (06) : 499 - 512
  • [5] Meta-Analysis Comparing Safety and Efficacy of Left Bundle Branch Area Pacing Versus His Bundle Pacing
    Yuan, Zhongyu
    Cheng, Liting
    Wu, Yongquan
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2022, 164 : 64 - 72
  • [6] Acute procedural outcomes of left bundle branch area pacing compared to His-bundle pacing
    Haeberlin, Andreas
    Seiler, Jens
    Kozhuharov, Nikola
    Baldinger, Samuel
    Servatius, Helge
    Madaffari, Antonio
    Thalmann, Gregor
    Kuffer, Thomas
    Muhl, Aline
    Tanner, Hildegard
    Roten, Laurent
    Reichlin, Tobias
    Noti, Fabian
    [J]. SWISS MEDICAL WEEKLY, 2023, 153 : 88S - 88S
  • [7] Feasibility and safety of His bundle pacing versus left bundle branch area pacing: insights from a 2-year single centre experience
    De Pooter, J.
    Calle, S.
    Timmermans, F.
    Van Heuverswyn, F.
    [J]. ACTA CARDIOLOGICA, 2020, 75 (06) : 573 - 574
  • [8] Feasibility and safety of left bundle branch area pacing in patients with septal hypertrophy
    Ozpak, Emine
    Van Heuverswyn, Frederic
    Timmermans, Frank
    De Pooter, Jan
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (11) : 2255 - 2261
  • [9] Feasibility and safety of both His bundle pacing and left bundle branch area pacing in atrial fibrillation patients: intermediate term follow-up
    Ye, Yang
    Zhang, Kai
    Yang, Ying
    Jiang, Dongmei
    Pan, Yiwen
    Sheng, Xia
    Wang, Bei
    Yu, Chan
    Zhang, Zuwen
    Zhang, Jiefang
    Wang, Li
    Jiang, Jiangfen
    Sun, Yaxun
    Liu, Qiang
    Cheng, Yunxian
    Gao, Bo
    Wang, Min
    He, Hong
    Jiang, Chenyang
    Fu, Guosheng
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (02) : 271 - 280
  • [10] Feasibility and safety of both His bundle pacing and left bundle branch area pacing in atrial fibrillation patients: intermediate term follow-up
    Yang Ye
    Kai Zhang
    Ying Yang
    Dongmei Jiang
    Yiwen Pan
    Xia Sheng
    Bei Wang
    Chan Yu
    Zuwen Zhang
    Jiefang Zhang
    Li Wang
    Jiangfen Jiang
    Yaxun Sun
    Qiang Liu
    Yunxian Cheng
    Bo Gao
    Min Wang
    Hong He
    Chenyang Jiang
    Guosheng Fu
    [J]. Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 271 - 280