Fe-Zeolite as on-Site Regenerable Adsorber for Chlorohydrocarbons in Groundwater - from Laboratory to Pilot Test

被引:0
|
作者
Georgi, Anett [1 ]
Koehler, Robert [1 ]
Woszidlo, Silke [1 ]
Mackenzie, Katrin [1 ]
Schierz, Ariette [1 ]
Schlosser, Alina [2 ]
Stanger, Hans-Juergen [2 ]
机构
[1] Helmholtz Ctr Environm Res, Dept Environm Engn, Permoserstr 15, D-04318 Leipzig, Germany
[2] eneotech Umwelt GmbH, Inselstr 19, D-67065 Ludwigshafen, Germany
关键词
Advanced oxidation processes; Heterogeneous Fenton; On-site adsorbent regeneration; Pilot test; Zeolite;
D O I
10.1002/cite.202300096
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study describes the design and upscaling of an on-site regenerable adsorbent fixed bed of Fe-loaded MFI zeolite for removal of chlorinated hydrocarbons (CHCs) from contaminated groundwater from laboratory studies to pilot scale. The zeolite has an excellent adsorption performance for the hydrophilic CHCs and can be regenerated on-site by flushing with H2O2 to degrade adsorbed contaminants by a catalytic Fenton-like reaction. In the pilot test, the Fe-zeolite (30 kg) maintained its performance over treatment of 1470 m3 of groundwater in 12 adsorption/regeneration cycles. High-silica iron-exchanged zeolite was applied for the first time in a pilot test for removal of chlorohydrocarbons from contaminated groundwater. The zeolite showed stable performance as adsorbent with intermittent on-site regeneration by flushing with hydrogen peroxide in 12 reuse cycles, treating about 50 000 bed volumes of groundwater. image
引用
收藏
页码:2006 / 2014
页数:9
相关论文
共 6 条
  • [1] Biodegradation of VOCs from printing press air by an on-site pilot plant bioscrubber and laboratory scale continuous yeast cultures
    Tom Granström
    Pia Lindberg
    Jyri Nummela
    Jouni Jokela
    Matti Leisola
    Biodegradation, 2002, 13 : 155 - 162
  • [2] Biodegradation of VOCs from printing press air by an on-site pilot plant bioscrubber and laboratory scale continuous yeast cultures
    Granström, T
    Lindberg, P
    Nummela, J
    Jokela, J
    Leisola, M
    BIODEGRADATION, 2002, 13 (02) : 155 - 162
  • [3] On-site determination of the radon concentration in water samples:: Methodical background and results from laboratory studies and a field-scale test
    Schubert, M
    Buerkin, W
    Peña, P
    Lopez, AE
    Balcázar, M
    RADIATION MEASUREMENTS, 2006, 41 (04) : 492 - 497
  • [4] On-site wind speed recovery from smartphone audio: Time domain deep learning approach, laboratory validation and outdoor field test
    Ti, Zilong
    Yang, Ling
    Li, Yongle
    MEASUREMENT, 2024, 229
  • [5] Dielectric measurement by open-ended coaxial line for hot-mix asphalt roads: From laboratory test to on-site investigation
    Fan, Benhui
    Bosc, Frederic
    Liu, Yu
    Fauchard, Cyrille
    NDT & E INTERNATIONAL, 2023, 138
  • [6] Treatment of spent process water from a fruit juice company for purposes of reuse: hybrid process concept and on-site test operation of a pilot plant
    Noronha, M
    Britz, T
    Mavrov, V
    Janke, HD
    Chmiel, H
    DESALINATION, 2002, 143 (02) : 183 - 196