Numerical study on the cooling performance and inlet mass flow rate per unit area of Ranque-Hilsch vortex tubes with different area ratios

被引:2
|
作者
Peng, He [1 ]
Xiangji, Guo [2 ,3 ]
机构
[1] Res Inst Shanxi Yanchang Petr Grp Co Ltd, Xian, Peoples R China
[2] Dalian Univ Technol, Sch Energy & Power, Key Lab Complex Energy Convers & Utilizat Liaoning, Dalian, Peoples R China
[3] Dalian Univ Technol, Ningbo Res Inst, Ningbo, Peoples R China
基金
中国国家自然科学基金;
关键词
Area ratio; energy separation; inlet mass flowrate per unit area; performance benchmark; Ranque-Hilsch vortex tube; ORIFICE NOZZLE NUMBER; ENERGY SEPARATION; DIAMETER RATIO; CFD ANALYSIS; COUNTERFLOW; HYDROGEN; OPTIMIZATION; PARAMETERS; PRESSURES; WORKING;
D O I
10.1080/10407782.2022.2156946
中图分类号
O414.1 [热力学];
学科分类号
摘要
The development of the Ranque-Hilsch vortex tube has stagnated since the 1950s, when Hilsch improved the vortex tube proposed by Ranque. Consequently, the performance of vortex tubes has remained constant for the past 70 years. In addition to the unclear flow structure and energy separation mechanism of vortex tubes, the lack of a mature design method for vortex tubes has also limited its widespread adoption for industrial applications. The inlet nozzle and main tube parameters have been studied extensively, and matching the inlet with the main tube is considered an important step in the design of a vortex tube; however, this process has not been studied extensively. In addition, although the temperature drop at the cold exit is a commonly adopted performance benchmark, it is not possible to establish a close relationship between this parameter and the geometric parameters of a vortex tube. This study investigates the relationship between the cooling performance and the area ratio of a vortex tube. The results indicate that the inlet mass flowrate per unit area has a positive correlation with the cooling performance, and its influence on the performance of a vortex tube is higher than that of the distribution of the reverse flow boundary. Therefore, the inlet mass flowrate per unit area can potentially be a geometric performance benchmark. However, further studies are required to develop better guidelines for optimizing the design and to obtain a deeper understanding of the energy separation mechanism of vortex tubes.
引用
收藏
页码:860 / 875
页数:16
相关论文
共 29 条
  • [1] COMPARISON OF COOLING CAPACITY OF THE RANQUE-HILSCH VORTEX TUBES WITH DIFFERENT DIAMETERS
    Godbole, Rutika
    Ramakrishna, P. A.
    4TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, ASTFE 2019, 2019,
  • [2] NUMERICAL INVESTIGATION ON COOLING PERFORMANCE OF RANQUE-HILSCH VORTEX TUBE
    Pouraria, Hassan
    Park, Warn-Gyu
    THERMAL SCIENCE, 2014, 18 (04): : 1173 - 1189
  • [3] Experimental investigation of the effects of threefold type Ranque-Hilsch vortex tube and six cascade type Ranque-Hilsch vortex tube on the performance of counter flow Ranque-Hilsch vortex tubes
    Dincer, Kevser
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (06): : 1366 - 1371
  • [4] Fuzzy Modeling of Performance of Counterflow Ranque-Hilsch Vortex Tubes with Different Geometric Constructions
    Dincer, K.
    Tasdemir, S.
    Baskaya, S.
    Ucgul, I.
    Uysal, B. Z.
    NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 2008, 54 (06) : 499 - 517
  • [5] A new approach to study and optimize cooling performance of a Ranque-Hilsch vortex tube
    Shamsoddini, Rahim
    Khorasani, Ahmadreza Faghih
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (08): : 2339 - 2348
  • [6] Analysis of the flow mixing and energy separation in a Ranque-Hilsch vortex tube based on an area ratio study
    Guo, Xiangji
    Cao, Leilei
    Zhang, Bo
    Li, Nian
    Tang, Fengyi
    APPLIED THERMAL ENGINEERING, 2023, 226
  • [7] Experimental Study About Performance Analysis of Parallel Connected Ranque-Hilsch Counter Flow Vortex Tubes With Different Nozzle Numbers and Materials
    Kaya, Huseyin
    Gunver, Fahrettin
    Uluer, Onuralp
    Kirmaci, Volkan
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2018, 140 (11):
  • [8] The effects of orifice nozzle number and nozzle made of polyamide plastic and aluminum with different inlet pressures on heating and cooling performance of counter flow Ranque-Hilsch vortex tubes: An experimental investigation
    Cebeci, Ismail
    Kirmaci, Volkan
    Topcuoglu, Umit
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 72 : 140 - 146
  • [9] NUMERICAL SIMULATION OF DIFFERENT TURBULENCE MODELS AIMING AT PREDICTING THE FLOW AND TEMPERATURE SEPARATION IN A RANQUE-HILSCH VORTEX TUBE
    Azizi, Seied Hossein
    Andalibi, Mahmoud Reza
    Saleh, Seied Reza
    Kahrom, Mohsen
    THERMAL SCIENCE, 2014, 18 (04): : 1159 - 1171
  • [10] Experimental investigation of the effects of length to diameter ratio and nozzle number on the performance of counter flow Ranque-Hilsch vortex tubes
    Dincer, K.
    Baskaya, S.
    Uysal, B. Z.
    HEAT AND MASS TRANSFER, 2008, 44 (03) : 367 - 373