An experimental study to improve cooling on a hot plate using phase change materials and high-frequency ultrasound

被引:3
|
作者
Khanmohammadi, Shoaib [1 ]
Azimi, Neda [2 ]
Sharifzadeh, Esmail [3 ,4 ]
Rahimi, Masoud [2 ,3 ]
Azimi, Pedram [1 ]
机构
[1] Kermanshah Univ Technol, Dept Mech Engn, Kermanshah, Iran
[2] Razi Univ, Adv Chem Engn Res Ctr, CFD Res Div, Kermanshah, Iran
[3] Razi Univ, Fac Petr & Chem Engn, Dept Chem Engn, Kermanshah, Iran
[4] Razi Univ, Adv Chem Engn Res Ctr, Polymer Res Div, Kermanshah, Iran
关键词
Heat transfer; Ultrasonic; Phase change material; Cooling; Piezoelectric; THERMAL-ENERGY STORAGE; CHANGE MATERIALS PCMS; HEAT-TRANSFER; COMPOSITE; PERFORMANCE; EFFICIENCY; PARAFFIN; MANAGEMENT; NANOFLUID; WAVES;
D O I
10.1016/j.est.2023.107930
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The purpose of current study is investigation the use of ultrasonic energy and phase change materials (PCM) in cooling a hot plate. Hence an experimental setup is prepared and a PCM is placed between two aluminum plates in a way the upper plate is hot and the lower plate is cold. Water or CuO nanofluid flows in a container equipped with five 1.7 MHz piezoelectrics. The lower aluminum plate is cooled by cold vapor generated by an ultrasonic device, which increases the temperature gradient in the lower and upper layers of the PCM and simultaneously, the heat of the upper hot plate absorbs by PCM. To increase the thermal conductivity of PCM, different layers of metal matrix sheets (MMS) placed inside it. The effects of PCM thickness, weight fractions (%wt) of CuO nanoparticles (NPs) and number of MMS on the temperature of hot and cold plates is evaluated. The RSM method is used to design the experiments and obtain the optimal conditions of the proposed system. Results show that the use of pure PCM can decrease the hot plate temperature from 62.5 degrees C to 58.64 degrees C. Propagation of ultrasonic waves to the bottom plate intensified decrease in the hot plate temperature. In addition, increasing the weight fraction of NPs as well as the number of MMS have positive effects on reducing the hot plate temperature. Increasing the thickness of PCM from 1 to 2.5 cm reduces the temperature of the hot plate and has the opposite effect for its thickness from 2.5 to 3 cm. Finally, it can be found that under optimal conditions (4 MMS and 3.5 % NPs) the hot plate temperature could be decreased from 62.5 degrees C to 43.3 degrees C.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Optical Switching of GeTe Phase Change Materials for High-Frequency Applications
    Crunteanu, Aurelian
    Huitema, Laure
    Orlianges, Jean-Christophe
    Guines, Cyril
    Passerieux, Damien
    Wong, Hang
    [J]. 2017 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON ADVANCED MATERIALS AND PROCESSES FOR RF AND THZ APPLICATIONS (IMWS-AMP), 2017,
  • [2] EXPERIMENTAL CATARACT PRODUCTION BY HIGH-FREQUENCY ULTRASOUND
    LIZZI, FL
    PACKER, AJ
    COLEMAN, DJ
    [J]. ANNALS OF OPHTHALMOLOGY, 1978, 10 (07): : 934 - 942
  • [3] Experimental study of lithium-ion battery cooling using mixture of phase change materials
    Pradeep, R.
    Venugopal, T.
    [J]. INTERNATIONAL JOURNAL OF ELECTRIC AND HYBRID VEHICLES, 2020, 12 (02) : 168 - 183
  • [4] Anatomical study of the sternoclavicular joint using high-frequency ultrasound
    Timothée Olivier
    Kevin Kasprzak
    Matthias Herteleer
    Xavier Demondion
    Thibaut Jacques
    Anne Cotten
    [J]. Insights into Imaging, 13
  • [5] Anatomical study of the sternoclavicular joint using high-frequency ultrasound
    Olivier, Timothee
    Kasprzak, Kevin
    Herteleer, Matthias
    Demondion, Xavier
    Jacques, Thibaut
    Cotten, Anne
    [J]. INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [6] Experimental Study on the Thermal Management Performance of Radiative Cooling Phase Change Materials
    Zhai, Huatian
    Fan, Desong
    Yu, Kunyang
    Li, Zhisong
    Li, Qiang
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (02): : 520 - 524
  • [7] EXPERIMENTAL OCULAR LESIONS PRODUCED BY HIGH-FREQUENCY ULTRASOUND
    LIZZI, FL
    PACKER, A
    COLEMAN, DJ
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 59 : S59 - S60
  • [8] EXPERIMENTAL NEUROPATHOLOGICAL STUDY OF EFFECTS OF HIGH-FREQUENCY FOCUSED ULTRASOUND ON BRAIN OF CAT
    ASTROEM, KE
    BALLANTINE, HT
    BELL, E
    [J]. JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 1961, 20 (04): : 484 - &
  • [9] EVALUATION OF ADHERENCE USING HIGH-FREQUENCY ULTRASOUND
    OUAFTOUH, M
    XU, WJ
    OURAK, M
    NONGAILLARD, B
    [J]. JOURNAL DE PHYSIQUE IV, 1992, 2 (C1): : 835 - 838
  • [10] High-frequency nanofluidics: An experimental study using nanomechanical resonators
    Karabacak, D. M.
    Yakhot, V.
    Ekinci, K. L.
    [J]. PHYSICAL REVIEW LETTERS, 2007, 98 (25)