Experimental analysis of one and two-stage thermoelectric heat pumps to enhance the performance of a thermal energy storage

被引:2
|
作者
Erro, I. [1 ]
Aranguren, P. [1 ]
Alzuguren, I. [1 ]
Chavarren, D. [1 ]
Astrain, D. [1 ]
机构
[1] Univ Publ Navarra, Inst Smart Cities, Pamplona, Spain
关键词
Two-stage thermoelectric heat pump; COP; Air heating; Thermal energy storage; HIGH-TEMPERATURE HEAT; OF-THE-ART; OPTIMIZATION; TECHNOLOGIES; ELECTRICITY; SYSTEMS; COOLER;
D O I
10.1016/j.energy.2023.129447
中图分类号
O414.1 [热力学];
学科分类号
摘要
This experimental study demonstrates the possibility to enhance the performance of a low-temperature thermal energy storage system (similar to 160 degrees C) based on airflow heating using electrical heaters by including thermoelectric technology. An improvement of the 17 % on COP is reached by using an optimized thermoelectric heat pump system to preheat the airflow, consisting of three one-stage and three pyramidal two-stage thermoelectric heat pumps sequentially installed along the airflow that is heating. This research experimentally analyses and compares the COP of three different configurations of thermo-electric heat pumps: one-stage, square two-stage, and pyramidal two-stage thermoelectric heat pumps. The experimental study aims to characterize the operation of each configuration for heating an airflow of 16.5 m(3)/h at 25 degrees C as ambient temperature. To that purpose, the airflow inlet temperature, voltage supply, and voltage ratio between stages have been modified. The experimental results show that for 25 degrees C as inlet temperature the one-stage thermoelectric heat pump has the best performance with a maximum generated heat of 78 W. Whereas, a two-stage thermoelectric heat pump is required when the inlet temperature increases. At 40 degrees C as inlet temperature, the square two-stage configuration provides the best performance with a voltage ratio of 2, which reaches a COP of 3.29 generating only 20 W of heat. However, the pyramidal two-stage configuration is able to achieve the maximum heat outputs with a voltage ratio of 1, generating 172; 161; 149 and 138 W, with corresponding COP values of 1.17; 1.16; 1.14 and 1.11 for inlet temperatures of 25; 40; 55 and 70 degrees C. This configuration is the one that achieves the greatest COP values with high inlet temperatures.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Heat transfer effect on optimal performance of two-stage thermoelectric heat pumps
    Chen, L.
    Li, J.
    Sun, F.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2007, 221 (12) : 1635 - 1641
  • [2] Performance analysis of two-stage thermal energy storage system of solar power tower plant
    Zhuang, Jiayan
    Bai, Fengwu
    Xu, Ershu
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [3] Performance analysis of a two-stage thermal energy storage system using concrete and steam accumulator
    Bai, Fengwu
    Xu, Chao
    APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) : 2764 - 2771
  • [4] Optimal design and thermal performance study of a two-stage latent heat thermal energy storage technology for heating systems
    Lu, Shilei
    Jia, Yanbing
    Liang, Bin
    Wang, Ran
    Lin, Quanyi
    He, Zijian
    APPLIED THERMAL ENGINEERING, 2023, 232
  • [5] Performance analysis and optimization of two-stage heat pipe-cooled thermoelectric chiller
    Chen Z.-J.
    Meng F.-K.
    Xu C.-X.
    Gongcheng Kexue Xuebao/Chinese Journal of Engineering, 2022, 44 (12): : 2177 - 2188
  • [6] RETRACTED: A novel configuration and performance for a two-stage thermoelectric heat pump system driven by a two-stage thermoelectric generator (Retracted Article)
    Chen, L.
    Meng, F.
    Sun, F.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2009, 223 (A4) : 329 - 339
  • [7] Effect of heat transfer on the performance of two-stage semiconductor thermoelectric refrigerators
    Chen, Lingen
    Li, Jun
    Sun, Fengrui
    Wu, Chih
    Journal of Applied Physics, 2005, 98 (03):
  • [8] Effect of heat transfer on the performance of two-stage semiconductor thermoelectric refrigerators
    Chen, LG
    Li, J
    Sun, FR
    Wu, C
    JOURNAL OF APPLIED PHYSICS, 2005, 98 (03)
  • [9] Performance optimization for two-stage thermoelectric refrigerator system driven by two-stage thermoelectric generator
    Meng, Fankai
    Chen, Lingen
    Sun, Fengrui
    CRYOGENICS, 2009, 49 (02) : 57 - 65
  • [10] Multivariable optimization of two-stage thermoelectric refrigerator driven by two-stage thermoelectric generator with external heat transfer
    Meng, Fankai
    Chen, Lingen
    Sun, Fengrui
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2010, 48 (10) : 731 - 742