Energy and exergy analysis of a cross flow solar air heater for thermohydraulic performance augmentation

被引:6
|
作者
Hegde, Avinash K. [1 ]
Pai, Raghuvir [1 ]
Karanth, K. Vasudeva [1 ]
机构
[1] Manipal Acad Higher Educ, Manipal Inst Technol, Dept Mech & Ind Engn, Manipal 576104, Karnataka, India
关键词
Thermo-hydraulic efficiency; DO radiation model; Cross flow; 4E analysis; Convective heat transfer; JET-IMPINGEMENT; THERMAL PERFORMANCE; ABSORBER PLATE; OPTIMIZATION; PARAMETERS;
D O I
10.1016/j.ijthermalsci.2023.108577
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study numerically examines the enhancement of thermo-hydraulic efficiency of a cross flow solar air heater (SAH) for Reynolds number ranging from 3000 to 21000. The thermal performance is investigated for various perforation hole diameters of absorber plate and varying number of rows of holes. Discrete Ordinates radiation model is used to simulate the solar radiation heat interactions within the computational domain. Maximum thermo-hydraulic efficiencies of 86.51% and 85.15% are observed for configurations with 3 rows and 4 rows of perforation holes with hole diameter ratio of 0.06 and 0.07 respectively. The maximum exergy efficiency is found to be 5.28%. The system's enviro-economic analysis shows that the CO2 mitigation rate is 1.12 t CO2/annum, whereas the environmental cost is 16.31 $/year. The exergo-economic parameter is computed as 1.18 kWh/$, while the energy cost is calculated as 0.049 $/kWh. Additionally, it is determined that the energy payback period is 5 months while the exergy payback period is 22 years. The heat map for the various configurations shows the economical operating range of the air heater. The envisaged SAH has the advantage of completely decimating the laminar sublayer throughout the absorber plate due to cross flow movement of air through the absorber plate unlike the conventional SAH.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Energy exergy and economic analysis of a multiple inlet solar air heater for augmented thermohydraulic performance
    Arunkumar, H. S.
    Kumar, Shiva
    Karanth, K. Vasudeva
    APPLIED THERMAL ENGINEERING, 2024, 246
  • [2] Thermohydraulic correlations and exergy analysis of a solar air heater duct with inclined baffles
    Nguyen Thanh Luan
    Nguyen Minh Phu
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 21 (21)
  • [3] Thermohydraulic performance analysis of solar air heater with helical roughness
    Bezbaruah, Parag Jyoti
    Kumar, Rahul
    Das, Rajat Subhra
    PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019, 2019,
  • [4] Analysis of Thermohydraulic Performance of Double Flow V-Corrugated Absorber Solar Air Heater
    Saha, Som Nath
    Sharma, Suresh Prasad
    INTERNATIONAL ENERGY JOURNAL, 2016, 16 (03): : 131 - 141
  • [5] Exergy analysis of an air solar heater
    Kaze, C. V. Aloyem
    Tchinda, R.
    INTERNATIONAL JOURNAL OF EXERGY, 2012, 11 (01) : 19 - 34
  • [6] Thermohydraulic performance augmentation in a solar air heater using a perforated circular segment vortex generator
    Nguyen Van Hap
    Phan Thanh Nhan
    Huynh Phuoc Hien
    Nguyen Minh Phu
    Environmental Science and Pollution Research, 2023, 30 : 65338 - 65350
  • [7] Thermohydraulic performance augmentation in a solar air heater using a perforated circular segment vortex generator
    Nguyen Van Hap
    Phan Thanh Nhan
    Huynh Phuoc Hien
    Nguyen Minh Phu
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (24) : 65338 - 65350
  • [8] Thermohydraulic performance analysis of an arc shape wire roughened solar air heater
    Sahu, Mukesh Kumar
    Prasad, Radha Krishna
    RENEWABLE ENERGY, 2017, 108 : 598 - 614
  • [9] Energy and exergy analysis of a new solar air heater with latent storage energy
    Bouadila, Salwa
    Lazaar, Mariem
    Skouri, Safa
    Kooli, Sami
    Farhat, Abdelhamid
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (27) : 15266 - 15274
  • [10] Energy and exergy analysis in double-pass solar air heater
    P VELMURUGAN
    R KALAIVANAN
    Sādhanā, 2016, 41 : 369 - 376