Assessing Leg Length and Offset in Anterior Total Hip Arthroplasty: Overlay Versus AP Pelvis Intraoperative Radiographic Techniques: A Retrospective Cohort Study

被引:1
|
作者
Burnham, Robert R., Jr. [1 ]
Bialek, Samantha E. [2 ]
Wozniak, Amy W. [3 ]
Brown, Nicholas M. [1 ]
机构
[1] Loyola Univ Med Ctr, Dept Orthopaed Surg & Rehabil, Maywood, IL 60153 USA
[2] Loyola Univ Chicago, Stritch Sch Med, Maywood, IL USA
[3] Loyola Univ Chicago, Ctr Translat Res, Maywood, IL USA
关键词
QUALITY-OF-LIFE; LIMB-LENGTH; FEMORAL OFFSET; DISCREPANCY; RECONSTRUCTION; REPLACEMENT; FLUOROSCOPY; INEQUALITY; PERCEPTION; PATIENT;
D O I
10.5435/JAAOS-D-22-00142
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction:Two intraoperative radiographic techniques to determine leg length and offset during anterior total hip arthroplasty (THA) are the AP pelvis and overlay techniques. The AP pelvis method measures LLDs and offset using AP fluoroscopic images, whereas the overlay method uses printed images of the native and replaced hips. The purpose of this study was to compare these techniques regarding clinical and radiographic LLD and offset discrepancies.Methods:Patients of a single surgeon at two hospitals from September 2017 to January 2021 were retrospectively reviewed. Clinically detectable LLD was recorded. Radiographic measurements were obtained from preoperative and postoperative radiographs. LLD was determined based on the vertical distance between the lesser trochanters and the ischial tuberosities. Total offset was measured using a combination of femoral and medial offset. The Student t-test, Fisher exact test, and Wilcoxon rank sum tests were used for statistical analysis.Results:Seventy-one procedures were done using the overlay technique and 61 used for the AP pelvis technique. No significant differences were observed in mean postoperative LLD (2.66 versus 2.88 mm, P = 0.66) and mean postoperative offset discrepancy (5.37 versus 4.21 mm, P = 0.143) between the overlay versus AP pelvis groups. The mean preoperative to postoperative absolute difference in offset was less than 5 mm in both groups. Clinically detectable LLD was noted in six of 71 patients in the overlay group and one of 61 in the AP pelvis group (P = 0.123).Conclusion:No notable differences were observed in intraoperative leg length and offset discrepancies during direct anterior THA between the AP pelvis and overlay techniques, suggesting they are equally effective in determining LLD and offset intraoperatively. The choice of technique to use anterior THA should be based primarily on the surgeon's preference, comfort, and available resources.
引用
收藏
页码:106 / 113
页数:8
相关论文
共 50 条
  • [1] Intraoperative measurement technique for improved accuracy of femoral offset and leg length in total hip replacement: a retrospective cohort study
    Geller-Hinich, Maayan
    Reshef, Noam
    Ben Natan, Merav
    Rothem, David E.
    INTERNATIONAL JOURNAL OF SURGERY OPEN, 2024, 62 (04) : 297 - 302
  • [2] The impact of operative approach and intraoperative imaging on leg length discrepancy and acetabular component angle in total hip arthroplasty: a retrospective cohort study
    Thompson, Zoe
    Khoshbin, Amir
    Ward, Sarah
    Brillantes, Jacqueline
    Melo, Luana
    Waddell, James P.
    Atrey, Amit
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (02) : 473 - 479
  • [3] The impact of operative approach and intraoperative imaging on leg length discrepancy and acetabular component angle in total hip arthroplasty: a retrospective cohort study
    Zoe Thompson
    Amir Khoshbin
    Sarah Ward
    Jacqueline Brillantes
    Luana Melo
    James P. Waddell
    Amit Atrey
    International Orthopaedics, 2024, 48 : 473 - 479
  • [4] The intraoperative use of a calliper predicts leg length and offset after total hip arthroplasty. Component subsidence influences the leg length
    Maliha Fansur
    Nagib A. Yurdi
    Reinhard Stoewe
    Journal of Orthopaedic Surgery and Research, 16
  • [5] The intraoperative use of a calliper predicts leg length and offset after total hip arthroplasty. Component subsidence influences the leg length
    Fansur, Maliha
    Yurdi, Nagib A.
    Stoewe, Reinhard
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [6] Accuracy of Leg Length and Hip Offset Measurements Using a Fluoroscopic Grid During Anterior Approach Total Hip Arthroplasty
    Doehrmann, Ross
    Comer, Brendan J.
    Chatterji, Rishi
    Diedring, Benjamin
    Knapp, Paul
    Afsari, Alan
    ARTHROPLASTY TODAY, 2023, 22
  • [7] An Intraoperative Method to Minimize Leg Length Discrepancy in Anterior Minimally Invasive Total Hip Arthroplasty-A Prospective Study
    Girolami, Mauro
    Bevoni, Roberto
    Artioli, Elena
    Beluzzi, Renata
    Vasco, Cosimo
    Caravelli, Silvio
    Baiardi, Annalisa
    Mosca, Massimiliano
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (06):
  • [8] Accuracy of leg length and femoral offset restoration after total hip arthroplasty with the utilisation of an intraoperative calibration gauge
    Enke, Oliver
    Levy, Yadin D.
    Bruce, Warwick J. M.
    HIP INTERNATIONAL, 2020, 30 (03) : 296 - 302
  • [9] Techniques and Technologies for the Intraoperative Assessment of Component Positioning, Leg Lengths, and Offset in Total Hip Arthroplasty: A Systematic Review
    Chung, Anna Cedric
    Bin Hazzaa, Ibrahim
    Hakim, Raja
    Zywiel, Michael G.
    ARTHROPLASTY TODAY, 2024, 27
  • [10] Effect of longer femoral head on leg length, offset, and range of motion in total hip arthroplasty: a simulation study
    Shimizu, Tomohiro
    Miyazaki, Takuji
    Yokota, Shunichi
    Ishizu, Hotaka
    Takahashi, Daisuke
    Iwasaki, Norimasa
    SCIENTIFIC REPORTS, 2024, 14 (01)