Dual-Energy CT-based Opportunistic Volumetric Bone Mineral Density Assessment of the Distal Radius

被引:6
|
作者
Gruenewald, Leon D. [1 ]
Koch, Vitali [1 ]
Martin, Simon S. [1 ]
Yel, Ibrahim [1 ]
Mahmoudi, Scherwin [2 ]
Bernatz, Simon [2 ]
Eichler, Katrin [2 ]
Gruber-Rouh, Tatjana [2 ]
Santos, Daniel Pinto Dos [2 ]
D'Angelo, Tommaso [4 ,5 ]
Wesarg, Stefan [6 ]
Herrmann, Eva [3 ]
Golbach, Rejane [3 ]
Handon, Marlin [2 ]
Vogl, Thomas J. [2 ]
Booz, Christian [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Div Expt Imaging, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
[2] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
[3] Univ Hosp Frankfurt, Dept Biostat & Math Modeling, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
[4] Univ Hosp Messina, Dept Biomed Sci & Morphol & Funct Imaging, Messina, Italy
[5] Erasmus Med Coll, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[6] Fraunhofer IGD, Darmstadt, Germany
关键词
COMPUTED-TOMOGRAPHY; TRABECULAR BONE; FRACTURE; OSTEOPOROSIS; WRIST; ASSOCIATION; OUTCOMES; MARROW;
D O I
10.1148/radiol.223150
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In patients with distal radius fractures (DRFs), low bone mineral density (BMD) is associated with bone substitute use during surgery and bone nonunion, but BMD information is not regularly available.Purpose: To evaluate the feasibility of dual-energy CT (DECT)-based BMD assessment from routine examinations in the distal radius and the relationship between the obtained BMD values, the occurrence of DRFs, bone nonunion, and use of surgical bone substitute.Materials and Methods: Scans in patients who underwent routine dual-source DECT in the distal radius between January 2016 and December 2021 were retrospectively acquired. Phantomless BMD assessment was performed using the delineated trabecular bone of a nonfractured segment of the distal radius and both DECT image series. CT images and health records were examined to determine fracture severity, surgical management, and the occurrence of bone nonunion. Associations of BMD with the occurrence of DRFs, bone nonunion, and bone substitute use at surgical treatment were examined with generalized additive models and receiver operating characteristic analysis.Results: This study included 263 patients (median age, 52 years; IQR, 36-64 years; 132 female patients), of whom 192 were diagnosed with fractures. Mean volumetric BMD was lower in patients who sustained a DRF (93.9 mg/cm(3) vs 135.4 mg/cm(3); P < .001), required bone substitutes (79.6 mg/cm(3) vs 95.5 mg/cm(3); P < .001), and developed bone nonunion (71.1 mg/cm(3) vs 96.5 mg/cm(3); P < .001). Receiver operating characteristic curve analysis identified these patients with an area under the curve of 0.71-0.91 (P < .001). Lower BMD increased the risk to sustain DRFs, develop bone nonunion, and receive bone substitutes at surgery (P < .001).Conclusion: DECT-based BMD assessment at routine examinations is feasible and could help predict surgical bone substitute use and the occurrence of bone nonunion in patients with DRFs.(c) RSNA, 2023
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Diagnostic accuracy of quantitative dual-energy CT-based volumetric bone mineral density assessment for the prediction of osteoporosis-associated fractures
    Gruenewald, Leon D.
    Koch, Vitali
    Martin, Simon S.
    Yel, Ibrahim
    Eichler, Katrin
    Gruber-Rouh, Tatjana
    Lenga, Lukas
    Wichmann, Julian L.
    Alizadeh, Leona S.
    Albrecht, Moritz H.
    Mader, Christoph
    Huizinga, Nicole A.
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Wesarg, Stefan
    Vogl, Thomas J.
    Booz, Christian
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 3076 - 3084
  • [2] Diagnostic accuracy of quantitative dual-energy CT-based volumetric bone mineral density assessment for the prediction of osteoporosis-associated fractures
    Leon D. Gruenewald
    Vitali Koch
    Simon S. Martin
    Ibrahim Yel
    Katrin Eichler
    Tatjana Gruber-Rouh
    Lukas Lenga
    Julian L. Wichmann
    Leona S. Alizadeh
    Moritz H. Albrecht
    Christoph Mader
    Nicole A. Huizinga
    Tommaso D’Angelo
    Silvio Mazziotti
    Stefan Wesarg
    Thomas J. Vogl
    Christian Booz
    European Radiology, 2022, 32 : 3076 - 3084
  • [3] Dual-energy CT-based Assessment of the Trabecular Bone in Vertebrae
    Wesarg, S.
    Kirschner, M.
    Becker, M.
    Erdt, M.
    Kafchitsas, K.
    Khan, M. F.
    METHODS OF INFORMATION IN MEDICINE, 2012, 51 (05) : 398 - 405
  • [4] Dual-Energy CT-based Phantomless in Vivo Three-dimensional Bone Mineral Density Assessment of the Lumbar Spine
    Wichmann, Julian L.
    Booz, Christian
    Wesarg, Stefan
    Kafchitsas, Konstantinos
    Bauer, Ralf W.
    Kerl, J. Matthias
    Lehnert, Thomas
    Vogl, Thomas J.
    Khan, M. Fawad
    RADIOLOGY, 2014, 271 (03) : 778 - 784
  • [5] Dual-Energy CT-Based Bone Mineral Density Has Practical Value for Osteoporosis Screening around the Knee
    Choi, Keun Young
    Lee, Sheen-Woo
    In, Yong
    Kim, Man Soo
    Kim, Yong Deok
    Lee, Seung-Yeol
    Lee, Jin-Woo
    Koh, In Jun
    MEDICINA-LITHUANIA, 2022, 58 (08):
  • [6] Reproducibility of CT-based opportunistic vertebral volumetric bone mineral density measurements from an automated segmentation framework
    Bodden, Jannis
    Prucker, Philipp
    Sekuboyina, Anjany
    El Husseini, Malek
    Grau, Katharina
    Ruehling, Sebastian
    Burian, Egon
    Zimmer, Claus
    Baum, Thomas
    Kirschke, Jan S.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [7] Dual-energy digital radiography for the assessment of bone mineral density
    Tahvanainen, Paivi S.
    Lammentausta, Eveliina
    Pulkkinen, Pasi
    Tervonen, Osmo
    Jamsa, Timo
    Nieminen, Miika T.
    ACTA RADIOLOGICA, 2010, 51 (05) : 543 - 548
  • [8] Accuracy and precision of volumetric bone mineral density assessment using dual-source dual-energy versus quantitative CT: a phantom study
    Koch, Vitali
    Hokamp, Nils Grosse
    Albrecht, Moritz H.
    Gruenewald, Leon D.
    Yel, Ibrahim
    Borggrefe, Jan
    Wesarg, Stefan
    Eichler, Katrin
    Burck, Iris
    Gruber-Rouh, Tatjana
    Lenga, Lukas
    Vogl, Thomas J.
    Martin, Simon S.
    Wichmann, Julian L.
    Hammerstingl, Renate M.
    Alizadeh, Leona S.
    Mader, Christoph
    Huizinga, Nicole A.
    D'Angelo, Tommaso
    Ascenti, Giorgio
    Mazziotti, Silvio
    Booz, Christian
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
  • [9] Accuracy and precision of volumetric bone mineral density assessment using dual-source dual-energy versus quantitative CT: a phantom study
    Vitali Koch
    Nils Große Hokamp
    Moritz H. Albrecht
    Leon D. Gruenewald
    Ibrahim Yel
    Jan Borggrefe
    Stefan Wesarg
    Katrin Eichler
    Iris Burck
    Tatjana Gruber-Rouh
    Lukas Lenga
    Thomas J. Vogl
    Simon S. Martin
    Julian L. Wichmann
    Renate M. Hammerstingl
    Leona S. Alizadeh
    Christoph Mader
    Nicole A. Huizinga
    Tommaso D’Angelo
    Giorgio Ascenti
    Silvio Mazziotti
    Christian Booz
    European Radiology Experimental, 5
  • [10] Association of Phantomless Dual- Energy CT-based Volumetric Bone Mineral Density with the Prevalence of Acute Insufficiency Fractures of the Spine
    Gruenewald, Leon D.
    Koch, Vitali
    Yel, Ibrahim
    Eichler, Katrin
    Gruber-Rouh, Tatjana
    Alizadeh, Leona S.
    Mahmoudi, Scherwin
    D'Angelo, Tommaso
    Wichmann, Julian L.
    Wesarg, Stefan
    Vogl, Thomas J.
    Booz, Christian
    ACADEMIC RADIOLOGY, 2023, 30 (10) : 2110 - 2117