Scleral lens prescription and management practices: Emerging consensus

被引:11
|
作者
Schornack, Muriel M. [1 ]
Fogt, Jennifer [2 ]
Nau, Amy [3 ]
Nau, Cherie B. [1 ]
Harthan, Jennifer S. [4 ]
Cao, Dingcai [5 ]
Shorter, Ellen [5 ]
机构
[1] Mayo Clin, Dept Ophthalmol, Rochester, MN 55902 USA
[2] Ohio State Univ, Coll Optometry, Columbus, OH USA
[3] New England Coll Optometry, Boston, MA USA
[4] Illinois Coll Optometry, Chicago, IL USA
[5] Illinois Eye & Ear Infirm, Dept Ophthalmol, Chicago, IL USA
来源
CONTACT LENS & ANTERIOR EYE | 2023年 / 46卷 / 01期
基金
美国国家卫生研究院;
关键词
Contact lens; Contact lens solution; Landing zone; Scleral lens; MEDICAL APPLICATIONS; OUTCOMES; DRIVEN;
D O I
10.1016/j.clae.2021.101501
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe international scleral lens prescription and management practices across multiple practice types. Methods: For this cross-sectional study, scleral lens practitioners were asked to complete an electronic survey that requested information about a single scleral lens patient. Data collected included practitioner demographics (practice type, country, years of experience) and patient indications for scleral lens wear, fitting process, lens design, and care products. Results: Data were collected for 259 patients (419 eyes). Most participants (60%) practiced in the US, 75% worked primarily in community practice, and 58% claimed more than 5 years' experience fitting scleral lenses. Indications for scleral lens wear were corneal irregularity (87%), ocular surface disease (9%), and uncomplicated refractive error (4%). During the fitting process, the mean (SD) number of lenses ordered was 2.4 (1.6) (range, 1-16 lenses) during 3.8 (2.4) visits (range, 1-18 visits). Of patients, 62% used a daily surfactant cleaner, 47% used hydrogen peroxide disinfection, and 67% used single-use vials of nonpreserved saline. Mean lens diameter was 16.2 (1.1) mm (range, 11.8-23.0 mm). The landing zones were spherical (64%), toric (26%), quadrant -specific (7%), and custom (3%) designs. Optical power was spherical in 70%, toric in 27%, and higher-order aberration correcting in 3% of lenses. Only 5 lenses had multifocal optics. Conclusions: General consensus regarding prescribing patterns (lens design, wearing schedules, care products) between US vs non-US, community vs academic, and new vs established providers is reported in this study. Relatively low percentages of patients wearing lenses with advanced landing zones or optical designs suggest that these new options have not been widely adopted.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Scleral Lens Prescription and Management Practices: The SCOPE Study
    Harthan, Jennifer
    Nau, Cherie B.
    Barr, Joseph
    Nau, Amy
    Shorter, Ellen
    Chimato, Nicolette T.
    Hodge, David O.
    Schornack, Muriel M.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S228 - S232
  • [2] Current Trends in Scleral Lens Prescription, Management, and Evaluation
    Schornack, Muriel M.
    Nau, Cherie B.
    Harthan, Jennifer
    Shorter, Ellen
    Nau, Amy
    Fogt, Jenny
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2023, 49 (02): : 56 - 62
  • [3] Prescription Habits of Scleral Lenses for the Management of Corneal Irregularity and Ocular Surface Disease Among Scleral Lens Practitioners
    Shorter, Ellen
    Fogt, Jennifer
    Nau, Cherie
    Harthan, Jennifer
    Nau, Amy
    Schornack, Muriel
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2023, 49 (02): : 46 - 50
  • [4] Descemetocele Management With Therapeutic Scleral Lens Wear
    Gelles, John D.
    Bekerman, Vladislav P.
    Greenstein, Steven A.
    Shafiq, Misbah
    Hersh, Peter S.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2021, 47 (05): : 314 - 316
  • [5] Expert consensus on best practices for opioid prescription for chronic pain. Risk management and benefits
    Lligona, A.
    Bruguera, P.
    Henche, A.
    Lopez, A. I.
    Ortega, L.
    [J]. EUROPEAN PSYCHIATRY, 2018, 48 : S200 - S200
  • [6] Scleral Lens Issues and Complications; Their Recognition, Etiology, and Management
    Weissman, Barry A.
    [J]. OPTOMETRY AND VISION SCIENCE, 2021, 98 (02) : 176 - 176
  • [7] Scleral lens issues and complications: their recognition, etiology, and management
    Vincent, Stephen J.
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2021, 104 (07) : 811 - 811
  • [8] Lipid Keratopathy Management With Therapeutic Scleral Lens Wear
    Gelles, John D.
    Hillier, Kyla E.
    Krisa, Sydney
    Greenstein, Steven A.
    Hersh, Peter S.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (02): : 91 - 94
  • [9] Trends in Scleral Lens Fitting Practices: 2020 Scleral Lenses in Current Ophthalmic Practice Evaluation Survey
    Nau, Cherie B.
    Harthan, Jennifer S.
    Shorter, Ellen S.
    Fogt, Jennifer S.
    Nau, Amy C.
    Hochwald, Alexander P.
    Hodge, David O.
    Schornack, Muriel M.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2023, 49 (02): : 51 - 55
  • [10] PROCESS SAFETY MANAGEMENT - AN EMERGING CONSENSUS
    EARLY, WF
    [J]. HYDROCARBON PROCESSING, 1991, 70 (02): : 105 - 107