Study on debugging of lightning impulse voltage waveform for large capacity ±800kV converter transformer in high altitude area

被引:1
|
作者
Jiang, Ling [1 ,2 ]
Wang, Shengfu [1 ,2 ]
Kang, Jun [3 ]
Yang, Xiaoku [1 ,2 ]
Yao, Xiuyuan [4 ]
Zhang, Yitao [1 ,2 ]
Bao, Zhenghong [1 ,2 ]
Zhang, Yongsheng [5 ]
机构
[1] State Grid Qinghai Elect Power Co, Elect Power Res Inst, Xining, Peoples R China
[2] Qinghai Key Lab High Altitude Power Syst, Xining, Qinghai, Peoples R China
[3] Haibei Elect Power Co, State Grid Qinghai Elect Power Co, Haibei Tibetan Autonomous Prefecture, Shijiazhuang, Qinghai, Peoples R China
[4] China Elect Power Res Inst Co Ltd, Beijing, Peoples R China
[5] State Grid Qinghai Elect Power Co, Xining, Qinghai, Peoples R China
关键词
+/- 800kV converter transformer; lightning impulse test; time to half-value; front time; high altitude;
D O I
10.3389/fenrg.2023.1226519
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Qinghai-Henan +/- 800kV UHV DC power transmission project is an UHV channel specially constructed for clean energy delivery, +/- 800kV converter transformers of the project are assembled and tested in Xining at an altitude of 2500 m, full-wave lightning impulse test is one of the main means to evaluate converter transformer insulation performance, its valve side lightning impulse voltage waveform parameters often fail to meet IEC60076-3 standards because of the large winding to the ground capacitance. In order to effectively assess the lightning tolerance of converter transformer, a simulation model of impulse test circuit of +/- 800kV converter transformer was built based on the existing 6000kV/560kJ impulse voltage generator and ATP-EMTP simulation software, three kinds of optimization methods are proposed, which include increasing the wavetail resistance, increasing load capacitor, and connecting the wave head in parallel with different inductors, the results show that the single optimization method can not meet the waveform requirements. Therefore, a combinatorial optimization test method of increasing the wavetail resistance and connecting the wave head in parallel with different inductors is proposed, which is completed and verified in the full-wave lightning impulse test on the valve side of Qinghai +/- 800kV high-end converter transformer, the results show that the optimized test waveform parameters meet the standard requirements.
引用
收藏
页数:9
相关论文
共 11 条
  • [1] Influence of Lightning Flashover Criterion on the Calculated Lightning withstand Level of ±800kV UHVDC Transmission Lines at High Altitude
    Han, Yongxia
    Tang, Li
    Li, Licheng
    He, Qiuping
    Hao, Yanpeng
    Yao, Senjing
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) : 185 - 191
  • [2] The Arrester Protection Study for Valve Side of Highest Potential Converter Transformer in ±800kV UHVDC Project
    Zhou Xiaoqin
    Lv Jinzhuang
    Gou Ruifeng
    Zhao Jie
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 80 - +
  • [3] Modelling of Dry Lightning Impulse Test on 145 kV Oil Impregnated Paper Bushing for High Voltage Transformer
    Subroto, Cahyo
    Suwarno
    2016 3RD CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2016, : 263 - 268
  • [4] Over-voltage and lightning protection for 500 kV compact transmission line in high altitude area
    Zhao, Jian-Ning
    Gu, Ding-Xie
    Huo, Feng
    Cao, Jing
    Dai, Min
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (01): : 57 - 61
  • [5] Analysis of fault current and overvoltage at the neutral point of ±800 kV High-Voltage DC converter transformer
    Fu, Jiaqing
    Han, Yang
    Yang, Ping
    Wang, Congling
    Zalhaf, Amr S.
    ENERGY REPORTS, 2022, 8 : 292 - 300
  • [6] Analysis of fault current and overvoltage at the neutral point of ±800 kV High-Voltage DC converter transformer
    Fu, Jiaqing
    Han, Yang
    Yang, Ping
    Wang, Congling
    Zalhaf, Amr S.
    Energy Reports, 2022, 8 : 292 - 300
  • [7] HIGH VOLTAGE (800KV) TRANSMISSION ELECTRON MICROSCOPY STUDY OF A TYPE-III CARBONACEOUS CHONDRITE
    GREEN, HW
    RADCLIFF.SV
    HEUER, AH
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1970, 51 (04): : 341 - &
  • [8] Pollution Flashover Performance of Full-scale ±800 kV Converter Station Post Insulators at High Altitude Area
    Zhang, Chuyan
    Wang, Liming
    Guan, Zhicheng
    Zhang, Fuzeng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (03) : 717 - 726
  • [9] High-voltage Large-capacity Battery Energy Storage System Connecting to 35 kV Grid Without Transformer
    Liu C.
    Wu S.
    Wu X.
    Jiang X.
    Li R.
    Cai X.
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (02): : 881 - 892
  • [10] Research summary of the reactive power control on the receiving-end converter station of Yazhong-Jiangxi ±800kv ultra-high voltage direct current transmission project
    Yu, Kansheng
    Wu, Ying
    Zeng, Wei
    Zou, Jin
    Pan, Benren
    Xie, Guoqiang
    Wang, Zhicheng
    THIRD INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2019, 227