Seismic Behavior of Precast Bridge Column-Cap Beam Joints with Grouted Corrugated Duct Connections: Experimental and Numerical Study

被引:5
|
作者
Xu, Yazhou [1 ]
Wei, Kelun [2 ]
Zhang, Zuzhen [1 ]
Wang, Jiangbo [1 ]
Mao, Huinan [1 ]
Fu, Wenjie [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Shaanxi, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Civil Engn, 13,Yanta Rd, Xian 710055, Shaanxi, Peoples R China
关键词
Grouted corrugated ducts; Numerical simulation; Precast bridge column-cap beam joints; Pseudostatic cyclic loading test; Seismic performance; PERFORMANCE; CONSTRUCTION;
D O I
10.1061/JBENF2.BEENG-5780
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presented an assembly scheme that was based on bundled bars-grouted corrugated duct connections. The scheme was used for the connection between the bridge column with bundled bars and the cap beam in an elevated subway station. Two 1/3-scale bridge column-cap beam joint specimens were designed and fabricated to verify the scheme. The test specimens included a precast assembly specimen and a cast-in-place (CIP) specimen. Pseudostatic cyclic loading tests were performed to investigate the flexural capacity, failure mode, and hysteretic behavior of the CIP and precast assembly specimens. The test results showed that: (1) the flexural capacity of the precast assembly specimen was close to that of the CIP specimen; (2) the energy dissipation capacity of the precast assembly specimen was weaker compared with that of the CIP specimen; and (3) the assembly scheme that was based on bundled bars-grouted corrugated duct connections was reliable. Finally, the finite-element model for the test specimens was established by calling the PQ-FIBER user subroutine developed by Tsinghua University with ABAQUS to study the seismic performance of the test specimens. Compared with the test results, the finite-element models could simulate the failure mode and hysteretic behavior of the reinforced-concrete specimens.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Study on seismic performance of precast bridge column-cap beam joints based on bundled bars- grouted corrugated duct
    Xu Y.
    Wei K.
    Li M.
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2023, 56 (02): : 12 - 22
  • [2] Impulsive seismic response of bridge column-cap beam joints
    Gibson, N
    Filiatrault, A
    Ashford, SA
    ACI STRUCTURAL JOURNAL, 2002, 99 (04) : 470 - 479
  • [3] Seismic performance of precast bridge columns with new grouted corrugated duct connections
    Shen, Yin
    Wang, Yi
    Fu, Chenxi
    Zhou, Qing
    ENGINEERING STRUCTURES, 2025, 327
  • [4] Experimental study on the seismic behavior of a novel type of precast column-steel beam connection with grouted corrugated metallic duct
    Qi, Ligang
    Ma, Minglei
    Chen, Yueshi
    Liao, Xiandong
    Hua, Jingjing
    Liu, Yanan
    Zhang, Shiqian
    Li, Chang
    Lu, Lei
    STRUCTURAL CONCRETE, 2024, : 5108 - 5138
  • [5] Experimental Study on the Seismic Performance of Improved Grouted Corrugated Duct Connection (GCDC) Design for Precast Concrete Bridge Column
    Wang, Zhiqiang
    Wu, Chengjun
    Li, Tiantian
    Xiao, Wei
    Wei, Hongyi
    Qu, Hongya
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (05) : 2469 - 2490
  • [6] Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction
    Ameli, M. J.
    Parks, Joel E.
    Brown, Dylan N.
    Pantelides, Chris P.
    PCI JOURNAL, 2015, : 80 - 103
  • [7] Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction
    Gamble, Bill
    PCI JOURNAL, 2015, : 97 - 98
  • [8] Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction
    Ameli, M.J.
    Parks, Joel E.
    Brown, Dylan N.
    Pantelides, Chris P.
    PCI Journal, 2015, 60 (02): : 80 - 103
  • [9] Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction Response
    Pantelides, Chris P.
    Ameli, M. J.
    Parks, Joel E.
    Brown, Dylan N.
    PCI JOURNAL, 2015, : 98 - 99
  • [10] Seismic behavior of precast reinforced concrete column-to-foundation grouted duct connections
    Hofer, Lorenzo
    Zanini, Mariano Angelo
    Faleschini, Flora
    Toska, Klajdi
    Pellegrino, Carlo
    BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (12) : 5191 - 5218