Simultaneous Detection of Prolactin and Growth Hormone Using a Dual-label Time-resolved Fluorescence Immunoassay

被引:0
|
作者
Zhong, Shuhai [1 ]
Liang, Huankun [2 ]
Peng, Fenglan [3 ]
Lu, Yanhong [2 ]
Liu, Tiancai [4 ]
Kulchytski, Uladzimir [5 ]
Dong, Wenqi [6 ]
机构
[1] Guangzhou Youdi Biotechnol Co Ltd, Guangzhou 510663, Peoples R China
[2] Jinan Laide Biotechnol Co Ltd, Jinan 271100, Peoples R China
[3] Taian Disabled Soldiers Hosp Shandong Prov, Tai An 271099, Peoples R China
[4] Southern Med Univ, Sch Lab Med & Biotechnol, Guangzhou 510515, Guangdong, Peoples R China
[5] Natl Acad Sci Belarus, Inst Physiol, Minsk 220072, BELARUS
[6] Guangzhou Zhenda Biopharmaceut Technol Co Ltd, 3 Juquan Rd, Guangzhou 510663, Peoples R China
关键词
Prolactin; Growth hormone; Time-resolved fluorescence immunoassay; Serum; CANCER; DIAGNOSIS;
D O I
10.1007/s10895-023-03395-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Prolactin (PRL) and growth hormone (GH) are two important hormones secreted by the pituitary gland, and their abnormal levels are often related to disease status. This study aimed to establish a new dual-label time-resolved fluorescence immunoassay (TRFIA) to quantitatively measure PRL and GH levels in serum. A sandwich TRFIA was optimized and established: anti-PRL/GH antibodies immobilized on 96-well plates captured PRL/GH and then banded together with anti-PRL/GH paired antibodies labeled with europium(III) (Eu3+)/samarium(III) (Sm3+) chelates. Finally, a time-resolved analyzer measured the Eu3+/Sm3+ fluorescence values. Clinical serum samples were used to evaluate the detection performance of this method. The sensitivities of this dual-label TRFIA were 0.35 ng/mL and 0.45 ng/mL, respectively, and the detection range was between 0.1 and 1000 ng/mL. All the cross-reactivities were lower than 1.07%. The intra-assay and interassay coefficients of variation were 2.18-7.85% and 2.25-7.30%, respectively. Compared with the registered TRFIA kits, a high Pearson coefficient (r = 0.9626 and 0.9675) was observed. This dual-label TRFIA has high sensitivity, accuracy and specificity with good clinical detection performance, representing a suitable alternative to existing methods for determining PRL and GH levels, and is expected to be used in the clinic in the future.
引用
收藏
页码:1417 / 1422
页数:6
相关论文
共 50 条
  • [1] Simultaneous detection of sulfamethazine and sulfaquinoxaline using a dual-label time-resolved fluorescence immunoassay
    Le, Tao
    Yan, Peifeng
    Liu, Jin
    Wei, Shu
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (07): : 1264 - 1269
  • [2] Simultaneous detection of deoxynivalenol and zearalenone by dual-label time-resolved fluorescence immunoassay
    Zhang, Jue
    Gao, Lei
    Zhou, Bin
    Zhu, Lan
    Zhang, Yi
    Huang, Biao
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2011, 91 (02) : 193 - 197
  • [3] Simultaneous detection of two verotoxin genes using dual-label time-resolved fluorescence immunoassay with duplex PCR
    Watanabe, K
    Arakawa, H
    Maeda, M
    LUMINESCENCE, 2002, 17 (02) : 123 - 129
  • [4] A DUAL-LABEL TIME-RESOLVED FLUORESCENCE IMMUNOASSAY FOR THE SIMULTANEOUS DETERMINATION OF β-HUMAN CHORIONIC GONADOTROPIN AND PROGESTERONE
    Sun, Wenqiao
    Ren, Shoulei
    Yuan, Guangwen
    Wang, Yan
    Li, Laiqing
    Zhang, Licheng
    ANALYTICAL LETTERS, 2014, 47 (18) : 2900 - 2908
  • [5] A dual-label time-resolved fluorescence immunoassay for the simultaneous determination of ferritin and β2-microglobulin
    Liu, Zhi
    Huang, Jing
    Ou, Rui-ming
    Yao, Meng-dong
    She, Yan-lin
    Chen, Rui
    Li, Cheng
    Xu, Li
    Abudureyimu, Aikebaier
    Zhang, Qing
    Liu, Shuang
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2017, 31 (06)
  • [6] A Dual-Label Time-Resolved Fluorescence Immunoassay for the Simultaneous Determination of Cardiac Troponin T and Myoglobin
    Wang, Ling
    Xu, Mujuan
    Huang, Ruolan
    Chang, Xiao
    Chen, Cuicui
    Li, Laiqing
    Zhang, Zhong
    Han, Yue
    SLAS TECHNOLOGY, 2017, 22 (02): : 130 - 135
  • [7] Simultaneous detection of fungal (1,3)-β-d-glucan and procalcitonin using a dual-label time-resolved fluorescence immunoassay
    Li Huitao
    Huang Zhifeng
    Lin Binchun
    Chen Xueyu
    Xiong Xiaoyun
    Cao Aifen
    Yang Chuanzhong
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2021, 68 (01) : 157 - 164
  • [8] A Dual-Label Time-Resolved Fluorescence Immunoassay for the Simultaneous Qualitative/Quantitative Detection of Hepatitis A and Hepatitis E Virus IgM Antibodies
    Sun, Wenqiao
    Chen, Cuicui
    Zhong, Shuhai
    Liang, Huankun
    Guo, Guiling
    Li, Laiqing
    Zhang, Licheng
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2023, 37 (01): : 345 - 351
  • [9] Development of a dual-label time-resolved fluorometric immunoassay for the simultaneous detection of two recombinant proteins in potato
    Bookout, JT
    Joaquim, TR
    Magin, KM
    Rogan, GJ
    Lirette, RP
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (12) : 5868 - 5873
  • [10] A dual-label time-resolved fluorescence immunoassay for the simultaneous determination of cystatin C and β2-microglobulin in urine
    Liu, Y.
    Liu, Y. H.
    Bei, W. J.
    Wang, K.
    Cui, T. T.
    Li, H. L.
    Wu, D. X.
    Chen, S. Q.
    Tan, N.
    Chen, J. Y.
    BRITISH JOURNAL OF BIOMEDICAL SCIENCE, 2017, 74 (04) : 193 - 197