Analysis of the distribution and orientation of oxygenated and non-oxygenated blood in a double outlet right ventricle

被引:2
|
作者
Collia, D. [1 ]
Angeli, E. [2 ]
Careddu, L. [2 ]
Pedrizzetti, G. [1 ]
机构
[1] Univ Trieste, Dept Engn & Architecture, Trieste, Italy
[2] IRCCS Azienda Osped Univ Bologna, Pediat Cardiac Surg & Adult Congenital Heart Dis P, Dept Cardiothorac & Vasc Med, Bologna, Italy
关键词
CONGENITAL HEART-DISEASE; KINETIC-ENERGY; SPONTANEOUS CLOSURE; REPAIRED TETRALOGY; SEPTAL-DEFECTS; LONG; FLOW; FALLOT; ECHOCARDIOGRAPHY; CIRCULATION;
D O I
10.1063/5.0163885
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Double outlet right ventricle (DORV) is a malformation of the fetal heart in utero that affects the ventricular chambers. It usually presents with a displacement of the aorta and more than half the circumference of both arterial valves in the right ventricle. A peculiar characteristic is given by an interventricular septal defect (VSD), which allows communication between the left ventricle and the right with consequent mixing of oxygenated and non-oxygenated blood inside the cavities. A crucial question in assessing the degree of severity of functional dysfunction concerns the percentage of oxygenated blood that is ejected into the primary circulation via the aorta, a result that depends on the details of the vortex flow pattern within the two ventricular chambers. This study analyzes a complete DORV case through the use of numerical simulations that allow to identify the concentrations of oxygenated and non-oxygenated blood passing through this geometry. Results show that the VSD presents a significant impact on the fluid dynamic performance of the two ventricles. The analysis of blood concentration allowed to quantify the presence of oxygenated blood ejected into the pulmonary artery and of non-oxygenated blood into the aortic artery. The analysis of this specific case aims to demonstrate how the fluid dynamics analysis of this rare malformation, properly coupled with imaging technology, can provide information that could not be obtained otherwise and that are relevant for a careful clinical management including timely therapeutic intervention.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Comparison between oxygenated and non-oxygenated hypothermic Machine Perfusion
    Manekeller, Steffen
    ZENTRALBLATT FUR CHIRURGIE, 2021, 146 (03): : 226 - 226
  • [2] Combustion time of the oxygenated and non-oxygenated fuels in an Otto cycle engine
    Mello, Pedro
    Wildner, Fabiano
    de Andrade, Giovanni Souza
    Cataluna, Renato
    da Silva, Rosangela
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2014, 36 (02) : 403 - 410
  • [3] Combustion time of the oxygenated and non-oxygenated fuels in an Otto cycle engine
    Pedro Mello
    Fabiano Wildner
    Giovanni Souza de Andrade
    Renato Cataluña
    Rosângela da Silva
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2014, 36 : 403 - 410
  • [4] OXYGENATED VERSUS NON-OXYGENATED FLUSH OUT AND STORAGE OF DCD PORCINE LIVERS
    Bruggenwirth, Isabel
    van der Plas, Willemijn
    van Leeuwen, Otto B.
    Thorne, Adam M.
    Adelmeijer, Jelle
    Rayar, Michel
    de Meijer, Vincent E.
    Porte, Robert J.
    TRANSPLANT INTERNATIONAL, 2021, 34 : 146 - 147
  • [5] Biodegradation of oxygenated and non-oxygenated imidazolium-based ionic liquids in soil
    Modelli, Alberto
    Sali, Andrea
    Galletti, Paola
    Samori, Chiara
    CHEMOSPHERE, 2008, 73 (08) : 1322 - 1327
  • [6] Oxygenated versus non-oxygenated flush out and storage of donor livers: An experimental study
    Bruggenwirth, Isabel M. A.
    van der Plas, Willemijn S.
    van Leeuwen, Otto B.
    Thorne, Adam M.
    Rayar, Michel
    de Meijer, Vincent E.
    Porte, Robert J.
    ARTIFICIAL ORGANS, 2022, 46 (02) : 201 - 209
  • [7] Novel results on fluence dependence and annealing behavior of oxygenated and non-oxygenated silicon detectors
    Martínez, C
    Rafí, JM
    Lozano, M
    Campabadal, F
    Santander, J
    Fonseca, L
    Ullán, M
    Moreno, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1377 - 1382
  • [8] ONE-SOLUTION TRIACID GENERAL STAIN WHICH DIFFERENTIATES OXYGENATED FROM NON-OXYGENATED RED BLOOD CORPUSCLES
    STEEDMAN, HF
    STAIN TECHNOLOGY, 1970, 45 (06): : 247 - &
  • [9] Novel results on fluence dependence and annealing behaviour of oxygenated and non-oxygenated silicon detectors
    Martínez, C
    Rafi, JM
    Lozano, M
    Campabadal, F
    Santander, J
    Fonseca, L
    Ullán, M
    Moreno, A
    2001 6TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS, 2002, : 91 - 97
  • [10] Greenhouse gases in non-oxygenated and artificially oxygenated eutrophied lakes during winter stratification
    Huttunen, JT
    Hammar, T
    Alm, J
    Silvola, J
    Martikainen, PJ
    JOURNAL OF ENVIRONMENTAL QUALITY, 2001, 30 (02) : 387 - 394