Diagnostic Performance of Contrast-Enhanced Ultrasound and High-Resolution Magnetic Resonance Imaging for Carotid Atherosclerotic Plaques A Systematic Review and Meta-Analysis

被引:3
|
作者
Li, Qiuping [1 ]
Cai, Miaomiao [1 ]
Wang, Hui [1 ]
Chen, Libo [1 ]
机构
[1] Jilin Univ, China Japan Union Hosp, Dept Ultrasonog, Changchun 130000, Jilin, Peoples R China
关键词
contrast-enhanced ultrasound; carotid plaque; carotid atherosclerosis; high-resolution magnetic resonance imaging; meta-analysis; MRI; VULNERABILITY; STENOSIS;
D O I
10.1002/jum.16122
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives The aim of this meta-analysis was to evaluate the diagnostic value of contrast-enhanced ultrasound (CEUS) and high-resolution magnetic resonance imaging (HR-MRI) in patients with carotid vulnerable plaques. Methods A systematic review was conducted in PubMed, Embase, Cochrane Library, and Web of Science using the search terms carotid artery, atherosclerotic plaque, CEUS, contrast-enhanced ultrasound, HR-MRI, and high-resolution magnetic resonance. Studies published since the establishment of the library until December 2021 were retrieved. The statistical analyses were performed with Meta-DiSc version 1.4. Beyond that, the potential sources of heterogeneity for CEUS and HR-MRI were explored. Results Nine articles were included in this study. For CEUS, the pooled sensitivity and specificity for detecting carotid vulnerable plaques 91% (95% confidence interval [CI]: 84%, 95%) and 67% (95% CI: 54%, 79%), respectively. For HR-MRI, the pooled sensitivity and specificity were 78% (95% CI: 72%, 83%) and 65% (95% CI, 56%, 73%), respectively. The area under the summary receiver operating characteristic curve for CEUS and HR-MRI were 0.9218 and 0.8129, respectively. However, the difference in diagnostic accuracy between CEUS and HR-MRI diagnostic accuracy was not statistically significant. Conclusions The study shows that the sensitivity of CEUS was higher than that of HR-MRI, and the specificity was similar to HR-MRI. CEUS and HR-MRI provide a similar diagnostic yield in detecting a vulnerable plaque. Thus, CEUS may be a useful tool for the diagnosis of carotid vulnerable plaques.
引用
收藏
页码:739 / 749
页数:11
相关论文
共 50 条
  • [1] Comparison of the diagnostic performance of contrast-enhanced ultrasound and high-resolution magnetic resonance imaging in the evaluation of histologically defined vulnerable carotid plaque: a systematic review and meta-analysis
    Hou, Chao
    Xuan, Ji-Qing
    Zhao, Li
    Li, Ming-Xing
    He, Wen
    Liu, Hui
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (08)
  • [2] Diagnostic performance of contrast-enhanced ultrasound and magnetic resonance imaging for detecting colorectal liver metastases: A systematic review and meta-analysis
    Zhang, Luni
    Zhang, Li
    Wang, Hui
    Chen, Libo
    Sui, Guoqing
    [J]. DIGESTIVE AND LIVER DISEASE, 2019, 51 (09) : 1241 - 1248
  • [3] Comparison of the Diagnostic Performance of Contrast-enhanced Ultrasound with That of Contrast-enhanced Computed Tomography and Contrast-enhanced Magnetic Resonance Imaging in the Evaluation of Renal Masses: A Systematic Review and Meta-analysis
    Furrer, Marc A.
    Spycher, Samuel C. J.
    Buettiker, Sophia M.
    Gross, Tobias
    Bosshard, Piet
    Thalmann, George N.
    Schneider, Marc P.
    Roth, Beat
    [J]. EUROPEAN UROLOGY ONCOLOGY, 2020, 3 (04): : 464 - 473
  • [4] Atherosclerotic Carotid Plaques: Multimodality Imaging with Contrast-enhanced Ultrasound, Computed Tomography, and Magnetic Resonance Imaging
    Hingwala, Divyata R.
    Chandrasekhakan, Kesavadas
    Thomas, Bejoy
    Sylaja, P. N.
    Unnikrishnare, M.
    Kapilamoorthy, T. R.
    [J]. ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2017, 20 (04) : 378 - 386
  • [5] Contrast-enhanced ultrasound for the evaluation of symptomatic and asymptomatic carotid plaques: A systematic review and meta-analysis
    Sultan, Salahaden R.
    Bashmail, Fatima T.
    Alzahrani, Nouf A.
    Alharbi, Shahd I.
    Anbar, Rayan
    Alkharaiji, Mohammed
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (08): : 1032 - 1043
  • [6] Diagnostic performance of dynamic contrast-enhanced magnetic resonance imaging for malignant ovarian tumors: a systematic review and meta-analysis
    Wei, Mingxiang
    Bo, Fan
    Cao, Hui
    Zhou, Wei
    Shan, Wenli
    Bai, Genji
    [J]. ACTA RADIOLOGICA, 2021, 62 (07) : 966 - 978
  • [7] Diagnostic performance of contrast-enhanced ultrasound for pancreatic neoplasms: A systematic review and meta-analysis
    Li, Xing-Zhao
    Song, Jun
    Sun, Zhi-Xia
    Yang, Yan-Yan
    Wang, Hui
    [J]. DIGESTIVE AND LIVER DISEASE, 2018, 50 (02) : 132 - 138
  • [8] Improved carotid atherosclerotic plaques imaging with contrast-enhanced ultrasound (CEUS)
    Clevert, D. A.
    Sommer, W. H.
    Helck, A.
    Saam, T.
    Reiser, M.
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 48 (1-3) : 141 - 148
  • [9] RETRACTED: Diagnostic Performance of Atherosclerotic Carotid Plaque Neovascularization with Contrast-Enhanced Ultrasound: A Meta-Analysis (Retracted Article)
    Dong, Shanshan
    Hou, Jianzhong
    Zhang, Caiyun
    Lu, Guilin
    Qin, Wenjuan
    Huang, Lei
    Zhou, Guangqin
    [J]. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [10] Contrast-enhanced Mammography: A Systematic Review and Meta-Analysis of Diagnostic Performance
    Cozzi, Andrea
    Magni, Veronica
    Zanardo, Moreno
    Schiaffino, Simone
    Sardanelli, Francesco
    [J]. RADIOLOGY, 2022, 302 (03) : 568 - 581