Concurrent validity of VmaxPro, Kinovea, and Speedograph for the assessment of peak barbell velocity during the bench press: A comparison of technological approaches and historical evolutions

被引:1
|
作者
Sandau, Ingo [1 ]
Ritterbusch, Arne [2 ]
Schelenz, Adrian [2 ]
Witt, Maren [2 ]
机构
[1] Inst Appl Training Sci, Dept Strength Power & Tech Sports, Marschnerstr 29, D-04109 Leipzig, Germany
[2] Univ Leipzig, Fac Sport Sci, Dept Sports Biomech, Leipzig, Germany
来源
JOURNAL OF HUMAN SPORT AND EXERCISE | 2023年 / 18卷 / 03期
关键词
Biomechanics; Video analysis; IMU; Linear velocity transducer; Calibration; VALIDATION; STRENGTH;
D O I
10.14198/jhse.2023.183.09
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Measurement of barbell velocity is a simple and effective way to control strength training. To assess the concurrent validity of different technological approaches measuring barbell velocity, video-analysis (Kinovea), linear velocity transducer (Speedograph), and an inertial measurement unit (VmaxPro) were compared. Sixty-eight female and male sport science students lifted two repetitions in the bench press exercise at self-selected barbell loads. Peak vertical barbell velocity (Vmax) was parallel measured during the concentric phase of the lift using the aforementioned devices. Concordance correlation coefficient (CCC), Deming regression (DR) and Bland-Altman analysis (BA) were used to assess relative and absolute concurrent validity of Vmax measured with Kinovea, Speedograph, and VmaxPro. Results confirmed high concurrent validity of Speedograph and VmaxPro (CCC = 0.99, standard deviation of differences [SDD] = 0.04 m & BULL;s-1) without detecting proportional or constant bias. In contrast, Vmax measured with Kinovea showed poor concurrent validity to Speedograph (CCC = 0.83) and VmaxPro (CCC = 0.81) with significant proportional and constant bias. Regression based re-calibration of Vmax from Kinovea resulted in an SDD = 0.09 m & BULL;s-1 compared to Speedograph and an SDD = 0.08 m & BULL;s-1 compared to VmaxPro. Among the three tested devices, Vmax assessed using Kinovea showed poor concurrent validity. Furthermore, as Kinovea showed proportional bias compared to Speedograph and VmaxPro, application-specific re-calibration of Kinovea should be applied when barbell velocity data is compared to Speedograph and VmaxPro.
引用
收藏
页码:612 / 621
页数:10
相关论文
共 3 条
  • [1] Reliability and Concurrent Validity of Seven Commercially Available Devices for the Assessment of Movement Velocity at Different Intensities During the Bench Press
    Perez-Castilla, Alejandro
    Piepoli, Antonio
    Delgado-Garcia, Gabriel
    Garrido-Blanca, Gabriel
    Garcia-Ramos, Amador
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2019, 33 (05) : 1258 - 1265
  • [2] Assessment of Two Velocity Measurement Approaches during Load-Spectrum Bench Press Throws
    Weiss, Lawrence W.
    Schilling, Brian
    Falvo, Michael
    Liggins, Tiffany
    Lohnes, Corey
    Barnes, Jacque
    Creasy, Andrea
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S216 - S216
  • [3] Comparison of the PUSH Band 2.0 and Vicon Motion Capture to Measure Concentric Movement Velocity during the Barbell Back Squat and Bench Press
    Pelka, Edward Z.
    Gadola, Carter
    McLaughlin, Daniel
    Slattery, Eric
    Claytor, Randal P.
    SPORTS, 2023, 11 (01)