MXene/Fluoropolymer-Derived Laser-Carbonaceous All-Fibrous Nanohybrid Patch for Soft Wearable Bioelectronics

被引:22
|
作者
Sharifuzzaman, Md [1 ,2 ]
Zahed, Md Abu [1 ,2 ]
Reza, Md Selim [1 ,2 ]
Asaduzzaman, Md [1 ,2 ]
Jeong, SeongHoon [1 ,2 ]
Song, Hyesu [1 ,2 ]
Kim, Dong Kyun [1 ,2 ]
Zhang, Shipeng [1 ,2 ]
Park, Jae Y. [1 ,2 ,3 ]
机构
[1] Kwangwoon Univ, Dept Elect Engn, 447-1 Wolgye Dong, Seoul 01897, South Korea
[2] Kwangwoon Univ, Human IoT Focused Res Ctr, 447-1 Wolgye Dong, Seoul 01897, South Korea
[3] SnE Solut Co Ltd, 447-1 Wolgye Dong, Seoul 01897, South Korea
关键词
ECGs; flexible electrochemical-electrophysiological hybrid biosensing patches; laser-carbonization; metal oxide-carbon fibrous nanohybrid electrodes; sweat glucose with pH adjustments; ELECTROCHEMICAL PROPERTIES; 001; FACETS; NANOFIBERS; SENSOR; ELECTRONICS; FABRICATION; COMPOSITES; EFFICIENT; TI3C2;
D O I
10.1002/adfm.202208894
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
While state-of-the-art skin-adhering fibrous electrodes have distinct benefits in personal wearable bioelectronics, considerable challenges persist in the production of fibrous-based soft conductive biosensing nanomaterials and their integration into efficient multisensing platforms. Here, an electrochemical-electrophysiological multimodal biosensing patch based on MXene/fluoropolymer nanofiber-derived hierarchical porous TiO2 nanocatalyst interconnected 3D fibrous carbon nanohybrid electrodes is reported. The nanohybrid electrode is produced via a one-step laser carbonaceous thermal oxidation, resulting in excellent elctroconductivity (sheet resistance = 15.6 ohm sq(-1)), rich active edges for effective electron transmission, and abundant support for enzyme immobilization. The features are attributed to three synergistic effects: i) conductivity of the interior, unoxidized MXene layers, ii) quick heterogeneous electron transmission of the exterior TiO2 nanoparticles, and iii) the porous disordered carbon's electron "bridge" effects. Based on the foregoing, the nanohybrid modified biosensing patch integrated into textile is demonstrated to be capable of simultaneously and precisely monitoring sweat glucose with pH adjustment (sensitivity of 77.12 mu A mm(-1) cm(-2) within physiological concentrations of 0.01-2 x 10(-3) m) and electrocardiogram signals (signal-to-noise ratio = 37.63 dB). This novel approach paves the way for controlled investigations of the nanohybrid, for several functionalization and design options, and for the mass manufacturing capabilities required in real-world applications.
引用
收藏
页数:14
相关论文
empty
未找到相关数据