Application of Y-Z deformable magnetic ring for recanalization of transanal single-access rectal stricture

被引:1
|
作者
Zhang, Miaomiao [1 ,2 ]
Zhuang, Yingying [3 ]
Mao, Jianqi [4 ]
Gong, Mingyan [4 ]
Zhang, Yuhan [5 ]
Shi, Aihua [2 ]
Lyu, Yi [1 ,2 ]
Yan, Xiaopeng [1 ,2 ]
机构
[1] Xi An Jiao Tong Univ, Dept Hepatobiliary Surg, Affiliated Hosp 1, 277 West Yanta Rd, Xian 710061, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Natl & Local Joint Engn Res Ctr Precis Surg & Rege, Affiliated Hosp 1, 76 West Yanta Rd, Xian 710061, Shaanxi, Peoples R China
[3] Baoji Cent Hosp, Baoji, Shaanxi, Peoples R China
[4] Xi An Jiao Tong Univ, Zonglian Coll, Xian 710061, Shaanxi, Peoples R China
[5] Xi An Jiao Tong Univ, Qide Coll, Xian 710061, Shaanxi, Peoples R China
关键词
COMPRESSION ANASTOMOSIS; ESTABLISHMENT;
D O I
10.1038/s41598-024-52531-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Magnetic compression anastomosis has been reported to have remarkable clinical outcomes. Here, we tested the applicability of a Y-Z deformable magnetic ring (DMR) for non-surgical manipulation of rectal stenosis (RS) in a beagle dog model under a transanal single-access condition. RS was modeled in 8 beagle dogs using partial ligation with silk thread. Under X-ray guidance, the Y-Z DMR was positioned at the proximal and distal ends of the RS, and the magnetic ring was bent into an "O" shape, such that the two rings were magnetically attracted. Operation time, complications during or after operation, and discharge time of the magnetic rings were recorded. The anastomosis bursting pressure was measured two weeks after removing the rings, and its formation was assessed through gross and histological examination. Partial ligation with a silk thread successfully established the canine RS model. After Y-Z DMR installation, the magnetic ring was successfully reconfigured from an "S" to an "O" shape. Strong attraction existed between the rings. The operation time was 9-15 min (average: 11.75 +/- 1.98 min). No rectal bleeding or perforation occurred during or after operation. The ring was naturally expelled 7-10 days after surgery. A pressure of > 300 mmHg was recorded at the point of anastomosis rupture. The rectal anastomosis appeared to have healed properly on the surface, which was confirmed histologically, signifying the success of this procedure. A Y-Z DMR facilitated the successful recanalization of transanal single-channel RS without needing surgery in an animal model.
引用
收藏
页数:9
相关论文
共 6 条
  • [1] Application of Y-Z Deformable Magnetic Ring for Recanalization of Transanal Single-Access Rectal Stricture
    Zhang, Miaomiao
    Xu, Shuqin
    Shi, Aihua
    Lyu, Yi
    Yan, Xiaopeng
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2023, 237 (05) : S70 - S71
  • [2] Application of Y–Z deformable magnetic ring for recanalization of transanal single-access rectal stricture
    Miaomiao Zhang
    Yingying Zhuang
    Jianqi Mao
    Mingyan Gong
    Yuhan Zhang
    Aihua Shi
    Yi Lyu
    Xiaopeng Yan
    Scientific Reports, 14
  • [3] Y-Z deformable magnetic ring for the treatment of rectal stricture: A case report and review of literature
    Zhang, Miao-Miao
    Sha, Huan-Chen
    Qin, Yuan-Fa
    Lyu, Yi
    Yan, Xiao-Peng
    WORLD JOURNAL OF GASTROENTEROLOGY, 2024, 30 (06) : 599 - 606
  • [4] Transanal Excision of a Rectal Adenoma Using Single-Access Laparoscopic Port
    Khoo, Robert E. H.
    DISEASES OF THE COLON & RECTUM, 2010, 53 (07) : 1078 - 1079
  • [5] A Novel Y-Z Magnetic Totally Implantable Venous Access Port Based on the Magnetic Anchor Technique
    Zhang, Miaomiao
    Lyu, Xin
    Wang, Juanjuan
    Shi, Aihua
    Lyu, Yi
    Yan, Xiaopeng
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2023, 237 (05) : S466 - S466
  • [6] Value of a novel Y-Z magnetic totally implantable venous access port in improving the success rate of one-time needle insertion
    Zhang, Miaomiao
    Lyu, Xin
    Wang, Juanjuan
    Shi, Aihua
    Zheng, Yunyun
    Lyu, Yi
    Yan, Xiaopeng
    FRONTIERS IN SURGERY, 2023, 10