Volar Locking Plate versus Closed Reduction and Immobilization for Distal Radius Fracture in the Elderly: Systematic Review and Meta-Analysis of Randomized Controlled Trials

被引:0
|
作者
Latypov, Niyaz [1 ,2 ,3 ,6 ]
Golubev, Igor [1 ,4 ]
Borisova, Alyona [5 ]
机构
[1] Russian Federat Ntl Med Res Ctr Traumatol & Orthop, Minist Hlth, Fed State Budgetary Inst, Moscow, Russia
[2] Private Clin Almaty, Alma Ata, Kazakhstan
[3] City Clin Hosp 4, Alma Ata, Kazakhstan
[4] European Clin Sports Traumatol & Orthoped ECSTO, European Med Ctr, Moscow, Russia
[5] RUDN Univ, Med Inst, Dept Normal Physiol, Moscow, Russia
[6] 45 Mirasmicrodist, Alma Ata 050043, Kazakhstan
关键词
distal radius fracture; elderly; volar locking plate; cast; immobilization; CLINICALLY IMPORTANT DIFFERENCE; NONOPERATIVE TREATMENT; FIXATION; OUTCOMES; QUICKDASH; SHOULDER; WRIST; OLDER;
D O I
10.1055/s-0043-1774331
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction A systematic review and meta-analysis of randomized controlled trials was conducted to compare surgical treatment using open reduction and internal fixation (ORIF) with volar locking plates (VLP) to conservative treatment with closed reduction and immobilization in elderly patients aged >= 60 years with acute displaced distal radius fractures.Methods A search of the MEDLINE, Scopus, and Central Register of Controlled Trials (CENTRAL) databases was conducted. Clinical and radiographic measures at 12 months were compared between groups by pooling the mean difference. The complication rates were compared by pooling relative risk ratios. Pooled mean differences of Disabilities of the Arm, Shoulder, and Hand (DASH) and Patient-Rated Wrist Evaluation (PRWE) results were compared with the published minimal clinically important difference (MCID) to evaluate the clinical relevance of the results.Results The initial search yielded 766 records, from which 6 articles were selected for the final analysis. The results of the DASH questionnaire at 12 months of follow-up were significantly lower in the surgical treatment group with a mean difference (MD) of -3.61 points (95% confidence interval [CI]: -6.48 to -0.73). No statistically significant difference was found in the PRWE questionnaire (MD = -3.14 points [95% CI: -7.32 to 1.04]). Radiological results were significantly better in the surgical treatment group and no significant difference in the overall complication rate between the groups was detected. Found MD for DASH and PRWE did not reach the published MCIDs.Conclusion This study suggests that for elderly patients aged >= 60 years with acute displaced distal radius fractures, surgical treatment using ORIF with VLP does not provide clinically relevant benefits compared with conservative treatment with closed reduction and immobilization at the 12-month follow-up, despite demonstrating better radiological results.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Efficacy and safety of volar locking plate versus cast immobilization for distal radius fractures: a systematic review and meta-analysis of randomized controlled trials
    Li, Faxiang
    Tan, Yuzhong
    Cui, Liuchao
    Tian, Lin
    JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2024, 59 : 108 - 116
  • [2] Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials
    Fu, Qiang
    Zhu, Lei
    Yang, Peng
    Chen, Aimin
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (06) : 602 - 610
  • [3] Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials
    Qiang Fu
    Lei Zhu
    Peng Yang
    Aimin Chen
    Indian Journal of Orthopaedics, 2018, 52 : 602 - 610
  • [4] Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials
    Qi Gou
    Xiong Xiong
    Dan Cao
    Yuanliang He
    Xu Li
    BMC Musculoskeletal Disorders, 22
  • [5] Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials
    Gou, Qi
    Xiong, Xiong
    Cao, Dan
    He, Yuanliang
    Li, Xu
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [6] Volar Locking Plate VS Cast Immobilization for Distal Radius Fractures: A Systematic Review and Meta-analysis
    Oldrini, Lorenzo Massimo
    Feltri, Pietro
    Albanese, Jacopo
    Lucchina, Stefano
    Filardo, Giuseppe
    Candrian, Christian
    SWISS MEDICAL WEEKLY, 2022, 152 : 27S - 27S
  • [7] Volar locking plate vs cast immobilization for distal radius fractures: a systematic review and meta-analysis
    Oldrini, Lorenzo Massimo
    Feltri, Pietro
    Albanese, Jacopo
    Lucchina, Stefano
    Filardo, Giuseppe
    Candrian, Christian
    EFORT OPEN REVIEWS, 2022, 7 (09) : 644 - 652
  • [8] VOLAR LOCKING PLATE FIXATION VERSUS CLOSED REDUCTION FOR DISTAL RADIAL FRACTURES IN ADULTS A Systematic Review and Meta-Analysis
    Lawson, Andrew
    Na, Michael
    Naylor, Justine M.
    Lewin, Adriane M.
    Harris, Ian A.
    JBJS REVIEWS, 2021, 9 (01)
  • [9] Comparison of Intramedullary Nail and Volar Locking Plate for Distal Radius Fractures: A Systematic Review and Meta-Analysis of Randomised Controlled Trials
    Chen, Zehong
    Zhu, Yinan
    Zhang, Wei
    Eltagy, Hassan
    Elerian, Sherif
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [10] Comparison between Volar Locking Plate and Kirschner Wire Fixation for Unstable Distal Radius Fracture: A Meta-Analysis of Randomized Controlled Trials
    Tariq, Muhammad A.
    Ali, Uzair
    Uddin, Qazi S.
    Altaf, Zahabia
    Mohiuddin, Ashar
    JOURNAL OF WRIST SURGERY, 2023, 13 (05) : 469 - 480