Estimating Blood Pressure during Exercise with a Cuffless Sphygmomanometer

被引:1
|
作者
Hayashi, Kenta [1 ]
Maeda, Yuka [1 ]
Yoshimura, Takumi [2 ]
Huang, Ming [3 ]
Tamura, Toshiyo [4 ]
机构
[1] Univ Tsukuba, Inst Syst & Informat Engn, Tsukuba 3058577, Japan
[2] Tokyo Metropolitan Coll Ind Technol, Dept Med & Welf Engn, Tokyo 1168523, Japan
[3] Nagoya City Univ, Sch Data Sci, Nagoya 4678501, Japan
[4] Waseda Univ, Future Robot Org, Tokyo 1698050, Japan
关键词
blood pressure (BP); photoplethysmogram (PPG); skewness signal quality index (SSQI); feature extraction; long short-term memory (LSTM); bidirectional LSTM; exercise; PULSE TRANSIT-TIME;
D O I
10.3390/s23177399
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurately measuring blood pressure (BP) is essential for maintaining physiological health, which is commonly achieved using cuff-based sphygmomanometers. Several attempts have been made to develop cuffless sphygmomanometers. To increase their accuracy and long-term variability, machine learning methods can be applied for analyzing photoplethysmogram (PPG) signals. Here, we propose a method to estimate the BP during exercise using a cuffless device. The BP estimation process involved preprocessing signals, feature extraction, and machine learning techniques. To ensure the reliability of the signals extracted from the PPG, we employed the skewness signal quality index and the RReliefF algorithm for signal selection. Thereafter, the BP was estimated using the long short-term memory (LSTM)-based neural network. Seventeen young adult males participated in the experiments, undergoing a structured protocol composed of rest, exercise, and recovery for 20 min. Compared to the BP measured using a non-invasive voltage clamp-type continuous sphygmomanometer, that estimated by the proposed method exhibited a mean error of 0.32 & PLUSMN; 7.76 mmHg, which is equivalent to the accuracy of a cuff-based sphygmomanometer per regulatory standards. By enhancing patient comfort and improving healthcare outcomes, the proposed approach can revolutionize BP monitoring in various settings, including clinical, home, and sports environments.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] EVALUATION OF A MICROPROCESSOR-CONTROLLED SPHYGMOMANOMETER FOR RECORDING BLOOD-PRESSURE DURING EXERCISE
    OGASAWARA, S
    FREEDMAN, SB
    RAM, J
    KELLY, DT
    AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (12): : 806 - 808
  • [2] EVALUATION OF A MICROPROCESSOR-CONTROLLED DIFFERENTIAL AUSCULTATORY SPHYGMOMANOMETER FOR RECORDING BLOOD-PRESSURE DURING EXERCISE
    OGASAWARA, S
    RAM, J
    KELLY, DT
    FREEDMAN, SB
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1988, 18 (03): : 366 - 366
  • [3] Cuffless Blood Pressure Devices
    Bradley, Corey K.
    Shimbo, Daichi
    Colburn, David Alexander
    Pugliese, Daniel N.
    Padwal, Raj
    Sia, Samuel K.
    Anstey, D. Edmund
    AMERICAN JOURNAL OF HYPERTENSION, 2022, 35 (05) : 380 - 387
  • [4] Cuffless Blood Pressure Measurement
    Mukkamala, Ramakrishna
    Stergiou, George S.
    Avolio, Alberto P.
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2022, 24 : 203 - 230
  • [5] Cuffless Blood Pressure Monitoring
    Abbasi, Jennifer
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2019, 322 (14): : 1343 - 1343
  • [6] EUROPEAN SOCIETY OF HYPERTENSION PROTOCOL FOR VALIDATING NOVEL CUFFLESS BLOOD PRESSURE MONITORS DURING HANDGRIP ISOMETRIC EXERCISE
    Kollias, Anastasios
    Stathopoulou, Panagiota
    Kyriakoulis, Konstantinos
    Avolio, Alberto
    Mukkamala, Ramakrishna
    Stergiou, George
    JOURNAL OF HYPERTENSION, 2024, 42
  • [7] Cuffless Blood Pressure Estimation During Moderate- and Heavy-Intensity Exercise Using Wearable ECG and PPG
    Landry, Cederick
    Hedge, Eric T.
    Hughson, Richard L.
    Peterson, Sean D.
    Arami, Arash
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (12) : 5942 - 5952
  • [8] Blood pressure during exercise
    Franz, LW
    DEUTSCHE ZEITSCHRIFT FUR SPORTMEDIZIN, 2003, 54 (02): : 55 - 56
  • [9] CUFFLESS BLOOD PRESSURE DEVICES AND INCONSISTENT TRACKING OF BLOOD PRESSURE CHANGES
    Tan, Isabella
    Barin, Edward
    Gueguen, Cindy
    Head, Geoff
    Avolio, Alberto
    Butlin, Mark
    JOURNAL OF HYPERTENSION, 2021, 39 : E118 - E118
  • [10] A hydrostatic pressure approach to cuffless blood pressure monitoring
    Shaltis, P
    Reisner, A
    Asada, H
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2173 - 2176