Infiltration Models in EnergyPlus: Empirical Assessment for a Case Study in a Seven-Story Building

被引:0
|
作者
Bastos Porsani, Gabriela [1 ]
Fernandez-Vigil Iglesias, Maria [1 ]
Echeverria Trueba, Juan Bautista [1 ]
Fernandez Bandera, Carlos [2 ]
机构
[1] Univ Navarra, Sch Architecture, Pamplona 31009, Spain
[2] Univ Extremadura, Sch Technol, Caceres 10003, Spain
关键词
blower door; building energy model; decarbonization; decay method; digital twins; infiltration modeling; AIR INFILTRATION; GENETIC ALGORITHM; PERFORMANCE; VENTILATION; IMPACT;
D O I
10.3390/buildings14020421
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The current decarbonization transition to be achieved by 2050 according to the European Council has given great prominence to the use of Digital Twins as tools for energy management. For their correct operation, it is essential to control the uncertainties of the energy models, which lead to differences between the measured and predicted data. One of the key parameters that is most difficult to assess numerically is air leakage. The existent infiltration models available in EnergyPlus were developed to be applied in low-rise residential buildings with fewer than three stories. Therefore, it is common to rely on air leakage equations employing predefined coefficients. This research presents an empirical assessment of the performance of two EnergyPlus air leakage models, the "Effective Leakage Area" and the "Flow Coefficient", in predicting dynamic infiltration within the attic of a seven-story building. Blower door tests, along with the application of CO2 tracer gas, were conducted to establish coefficients for the models. Then, they were evaluated in three independent periods according to the criteria established in the American Society for Testing Material D5157 Standard. Those models that only used in situ coefficients consistently met the standard across all three periods, demonstrating for both equations their accurate performance and reliability. For the best model derived from tracer gas data, the R2 and NMSE values are 0.94 and 0.019, respectively. In contrast, the model developed using blower door test data and EnergyPlus default values presented a 64% reduction in accuracy compared to the best one. This discrepancy could potentially lead to misleading energy estimates. Although other software options exist for estimating infiltration, this study specifically targets EnergyPlus users. Therefore, these findings offer valuable insights to make more informed decisions when implementing the infiltration models into energy simulations for high-rise buildings using EnergyPlus.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] A Case Study of Empirical Validation of EnergyPlus Infiltration Models Based on Different Wind Data
    Porsani, Gabriela Bastos
    Bandera, Carlos Fernandez
    [J]. BUILDINGS, 2023, 13 (02)
  • [2] Empirical evaluation of EnergyPlus infiltration model for a case study in a high-rise residential building
    Porsani, Gabriela Bastos
    Casquero-Modreg, Nuria
    Trueba, Juan Bautista Echeverria
    Bandera, Carlos Fernandez
    [J]. ENERGY AND BUILDINGS, 2023, 296
  • [3] Wave propagation in a seven-story reinforced concrete building I. Theoretical models
    Todorovska, MI
    Ivanovic, SS
    Trifunac, MD
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2001, 21 (03) : 211 - 223
  • [4] Simulation of the shaking table test of a seven-story shear wall building
    Martinelli, Paolo
    Filippou, Filip C.
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2009, 38 (05): : 587 - 607
  • [5] Lessons Learned from Seismic Analysis of a Seven-Story Concrete Test Building
    Waugh, Jonathan D.
    Sritharan, Sri
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2010, 14 (03) : 448 - 469
  • [6] Wave propagation in a seven-story reinforced concrete building II. Observed wavenumbers
    Todorovska, MI
    Ivanovic, SS
    Trifunac, MD
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2001, 21 (03) : 225 - 236
  • [7] Performance of Suspended Pipes and Their Anchorages During Shake Table Testing of a Seven-Story Building
    Hoehler, Matthew S.
    Panagiotou, Marios
    Restrepo, Jose I.
    Silva, John F.
    Floriani, Lucas
    Bourgund, Ulrich
    Gassner, Helmut
    [J]. EARTHQUAKE SPECTRA, 2009, 25 (01) : 71 - 91
  • [8] Shake table testing of a full-scale seven-story steel-wood apartment building
    van de Lindt, John W.
    Pryor, Steven E.
    Pei, Shiling
    [J]. ENGINEERING STRUCTURES, 2011, 33 (03) : 757 - 766
  • [9] Damage identification study of a seven-story full-scale building slice tested on the UCSD-NEES shake table
    Moaveni, Babak
    He, Xianfei
    Conte, Joel P.
    Restrepo, Jose I.
    [J]. STRUCTURAL SAFETY, 2010, 32 (05) : 347 - 356
  • [10] Rotations in a shear-beam model of a seven-story building caused by nonlinear waves during earthquake excitation
    Gicev, V.
    Trifunac, M. D.
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2009, 16 (04): : 460 - 482