Mechanical characteristics of the ureter and clinical implications

被引:2
|
作者
O'Meara, Sorcha [1 ,2 ]
Cunnane, Eoghan M. [3 ,4 ]
Croghan, Stefanie M. [1 ,2 ]
Cunnane, Connor V. [3 ,4 ]
Walsh, Michael T. [3 ,4 ]
O'Brien, Fergal J. [5 ,6 ,7 ]
Davis, Niall F. [1 ,2 ,8 ]
机构
[1] Royal Coll Surg Ireland RCSI, Dept Surg, Dublin, Ireland
[2] Blackrock Clin, Dept Urol, Dublin, Ireland
[3] Univ Limerick, Bernal Inst, Biomat Cluster, Limerick, Ireland
[4] Univ Limerick, Sch Engn, Limerick, Ireland
[5] Royal Coll Surg Ireland RCSI, Dept Anat & Regenerat Med, Tissue Engn Res Grp, Dublin, Ireland
[6] Trinity Coll Dublin, Trinity Ctr Biomed Engn, Dublin, Ireland
[7] Adv Mat & Bioengn Res Ctr AMBER RCSI & TCD, Dublin, Ireland
[8] Beaumont Hosp, Dept Urol & Transplant Surg, Dublin, Ireland
关键词
ELASTIC WALL PROPERTIES; ACCESS SHEATH; SAFETY WIRE; BALLOON DILATION; COLLAGEN CONTENT; RESIDUAL STRAIN; PULLING FORCES; PERISTALSIS; IMPACT; AGE;
D O I
10.1038/s41585-023-00831-1
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The ureteric wall is a complex multi-layered structure. The ureter shows variation in passive mechanical properties, histological morphology and insertion forces along the anatomical length. Ureter mechanical properties also vary depending on the direction of tensile testing and the anatomical region tested. Compliance is greatest in the proximal ureter and lower in the distal ureter, which contributes to the role of the ureter as a high-resistance sphincter. Similar to other human tissues, the ureteric wall remodels with age, resulting in changes to the mechanical properties. The passive mechanical properties of the ureter vary between species, and variation in tissue storage and testing methods limits comparison across some studies. Knowledge of the morphological and mechanical properties of the ureteric wall can aid in understanding urine transport and safety thresholds in surgical techniques. Indeed, various factors alter the forces required to insert access sheaths or scopes into the ureter, including sheath diameter, safety wires and medications. Future studies on human ureteric tissue both in vivo and ex vivo are required to understand the mechanical properties of the ureter and how forces influence these properties. Testing of instrument insertion forces in humans with a focus on defining safe upper limits and techniques to reduce trauma are also needed. Last, evaluation of dilatation limits in the mid and proximal ureter and clarification of tensile strength anisotropy in human specimens are necessary. The ureter has mechanical properties that vary along the anatomical length and change with age. In this Review, the authors provide an overview of ureter properties and discuss how understanding the mechanical forces that the ureter is exposed to during clinical interventions can be leveraged to improve surgical outcomes. The ureter shows variation in passive mechanical properties along the anatomical length. The proximal and distal ureter have the highest and lowest compliance, respectively.The uniaxial tensile strength of the ureter is anisotropic between axial and circumferential directions; however, results vary between studies, and further experiments are needed in human tissues.The passive mechanical properties of the ureter change with age, probably owing to the remodelling of the ureter wall.Various factors affect the forces required to insert ureteroscopes and ureteral access sheaths into the ureter, including sheath diameter, medications and the use of safety wires.Excessive insertion and withdrawal forces are associated with substantial ureteral trauma, and further testing of insertion forces in humans with a focus on defining a safe upper limit are required.
引用
收藏
页码:197 / 213
页数:17
相关论文
共 50 条
  • [1] Mechanical characteristics of the ureter and clinical implications
    Sorcha O’Meara
    Eoghan M. Cunnane
    Stefanie M. Croghan
    Connor V. Cunnane
    Michael T. Walsh
    Fergal J. O’Brien
    Niall F. Davis
    Nature Reviews Urology, 2024, 21 : 197 - 213
  • [2] Comparison of the mechanical properties of porcine buccal mucosa and ureter and the clinical implications
    S. O’Meara
    E. M. Cunnane
    C. M. McCarthy
    S. M. Croghan
    J. J.E. Mulvhill
    M. T. Walsh
    F. J. O’Brien
    N. F. Davis
    World Journal of Urology, 43 (1)
  • [3] Non-ectopic Duplicity of the Ureter: Clinical Implications
    Garbelotti Junior, S. A.
    Rodrigues Pereira, V.
    Marques, S. R.
    Moraes de Carvalho, L. O.
    Olave, E.
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2017, 35 (02): : 611 - 614
  • [4] ELASTIC CHARACTERISTICS OF URETER
    WALKER, D
    FINLAYSON, B
    JOURNAL OF UROLOGY, 1975, 114 (03): : 385 - 388
  • [5] Mechanical effects on the skeleton: Are there clinical implications?
    Forwood, MR
    OSTEOPOROSIS INTERNATIONAL, 2001, 12 (01) : 77 - 83
  • [6] Mechanical Effects on the Skeleton: Are There Clinical Implications?
    M. R. Forwood
    Osteoporosis International, 2001, 12 : 77 - 83
  • [7] MECHANICAL PROPERTIES OF CAT URETER
    WEISS, RM
    BASSETT, AL
    FEDERATION PROCEEDINGS, 1971, 30 (02) : A436 - &
  • [8] Clinical pathology of the ureter
    McKiernan, RL
    JOURNAL OF UROLOGY, 1926, 15 (01): : 51 - 55
  • [9] Capitellum Excision: Mechanical Implications and Clinical Consequences
    Root, Cassie Gyuricza
    Meyers, Kathleen
    Wright, Timothy
    Hotchkiss, Robert
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (02) : 346 - 350
  • [10] CLINICAL RECOGNITION OF RETROCAVAL URETER
    JACOBSEN, VC
    NEW YORK STATE JOURNAL OF MEDICINE, 1969, 69 (23) : 3060 - &