Development and validation of a bioanalytical method for the quantification of methotrexate from serum and capillary blood using volumetric absorptive microsampling (VAMS) and on-line solid phase extraction (SPE) LC-MS

被引:2
|
作者
Opitz, Patrick [1 ]
Fobker, Manfred [2 ]
Fabian, Jorg [1 ]
Hempel, Georg [1 ]
机构
[1] Univ Munster, Dept Pharmaceut & Med Chem, Clin Pharm, Munster, Germany
[2] Univ Hosp Munster, Cent facil Lab, Munster, Germany
关键词
Therapeutic drug monitoring (TDM); Methotrexate (MTX); Volumetric absorptive microsampling (VAMS); Acute lymphatic leukaemia; On-line SPE-LC-MS; MASS-SPECTROMETRY; KIDNEY INJURY; CHROMATOGRAPHY; PLASMA; PHARMACOKINETICS; POLYGLUTAMATES; BRAIN; MS/MS;
D O I
10.1016/j.chroma.2023.464610
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-dose methotrexate is part of the polychemotherapy protocols for the treatment of Acute lymphoblastic leukaemia (ALL) with therapeutic drug monitoring (TDM) to adjust leucovorin rescue. An immunoassay is commonly used to analyse serum samples collected via venous blood sampling. However, immunoassays cannot distinguish between the parent drug and its metabolites. Besides, the blood volume required by venous blood sampling is high. Therefore, the aim of this project was to develop a fast, simple, reliable and cost-efficient micro sampling bioanalytical method using capillary blood to minimize the harm of children and to analyse both methotrexate and its metabolites. To achieve this aim, a LC-MS method with on-line solid phase extraction (SPE) for the simultaneous detection of methotrexate and its metabolites from capillary blood using volumetricabsorptive-microsampling (VAMS) technology was developed and fully validated. Besides, the method was also validated and modified for serum samples to compare the results with the immunoassay. A singlequadrupole MS detector was used for detection. Through the use of on-line SPE technology, a lower limit of quantitation of 0.03 mu M for MTX and 7-OH-MTX and of 0.05 mu M for DAMPA from a 10 mu L capillary blood sample was achieved. The accuracy is between 90.0 and 104% and the precision between 4.7 and 12% for methotrexate and its metabolites, respectively. Because of the cross reactivity of the immunoassay a cross-validation was not successful. Besides, a correlation factor of 0.46 for MTX between plasma and whole-blood was found. A fast, simple, reliable and cost-efficient extraction and analysis LC-MS method could be developed and validated, which is applicable in ambulatory and clinical care.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Development and validation of a bioanalytical method for the quantification of axitinib from plasma and capillary blood using volumetric absorptive microsampling (VAMS) and on-line solid phase extraction (SPE) LC-MS
    Opitz, Patrick
    Zimmermann, Sebastian
    Laughlin, Anna M. Mc.
    Mueller, Lothar
    Fuxius, Stefan
    Illerhaus, Gerald
    Scherf-Clavel, Oliver
    Kloft, Charlotte
    Hempel, Georg
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 221
  • [3] Validation of LC-MS/MS method for determination of rosuvastatin concentration in human blood collected by volumetric absorptive microsampling (VAMS)
    Moon, Seol Ju
    Lee, Seon Eui
    Kwak, Yong-Geun
    Kim, Min-Gul
    TRANSLATIONAL AND CLINICAL PHARMACOLOGY, 2021, 29 (03) : 125 - 134
  • [4] Development of LC-MS/MS method for quantification of Lurasidone using volumetric absorptive microsampling (VAMS); a comparative study between dried blood and plasma samples
    Rajadhyaksha, Madhura
    Londhe, Vaishali
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1244
  • [5] Validation and clinical application of an LC-MS/MS method for the quantification of everolimus using volumetric absorptive microsampling
    Verheijen, R. B.
    Thijssen, B.
    Atrafi, F.
    Schellens, J. H. M.
    Rosing, H.
    de Vries, N.
    Beijnen, J. H.
    Mathijssen, R. H. J.
    Steeghs, N.
    Huitema, A. D. R.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1104 : 234 - 239
  • [6] Validation and clinical application of a LC-MS/MS method for simultaneous quantification of 4 immunosuppressants using volumetric absorptive microsampling
    Zahr, N.
    Tissot, N.
    Barrou, B.
    Arzouk, N.
    Nguyen, L.
    Calmus, Y.
    Conti, F.
    Funck-Brentano, C.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2021, 35 : 103 - 104
  • [7] Evaluation of automated micro solid phase extraction tips (μ-SPE) for the validation of a LC-MS/MS bioanalytical method
    Shen, Jim X.
    Tama, Cristina I.
    Hayes, Roger N.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 843 (02): : 275 - 282
  • [8] Volumetric absorptive microsampling (VAMS) in therapeutic protein quantification by LC-MS/MS: Investigation of anticoagulant impact on assay performance and recommendations for best practices in method development
    Gao, Xinliu
    Chen, Cindy
    Geng, Dong
    Bateman, Kevin P.
    Shi, Shuangping
    Woolf, Eric J.
    Xu, Yang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 196
  • [9] LC-MS/MS measurement of endogenous steroid hormones and phase II metabolites in blood volumetric absorptive microsampling (VAMS) for doping control purposes
    Ponzetto, Federico
    Parasiliti-Caprino, Mirko
    Leoni, Laura
    Marinelli, Lorenzo
    Nonnato, Antonello
    Nicoli, Raul
    Kuuranne, Tiia
    Ghigo, Ezio
    Mengozzi, Giulio
    Settanni, Fabio
    CLINICA CHIMICA ACTA, 2024, 557
  • [10] Personalization of pharmacotherapy with sirolimus based on volumetric absorptive microsampling (VAMS) in pediatric renal transplant recipients—from LC-MS/MS method validation to clinical application
    Arkadiusz Kocur
    Agnieszka Czajkowska
    Kamila Rębis
    Jacek Rubik
    Mateusz Moczulski
    Bartłomiej Kot
    Maciej Sierakowski
    Tomasz Pawiński
    Pharmacological Reports, 2024, 76 (6) : 1443 - 1455