Reliability, Validity, and Comparison of Barbell Velocity Measurement Devices during the Jump Shrug and Hang High Pull

被引:6
|
作者
Suchomel, Timothy J. [1 ,2 ]
Techmanski, Baylee S. [3 ]
Kissick, Cameron R. [4 ]
Comfort, Paul [2 ]
机构
[1] Carroll Univ, Dept Human Movement Sci, Waukesha, WI 53186 USA
[2] Univ Salford, Directorate Sport Exercise & Physiotherapy, Salford M6 6PU, England
[3] Athlete Performance, Mequon, WI 53092 USA
[4] New York Mets, Queens, NY 11368 USA
关键词
weightlifting; power clean; velocity-based training; load-velocity profile; FORCE-TIME CHARACTERISTICS; PROGRESSIVE EXERCISE; KINEMATIC VARIABLES; KINETIC VARIABLES; LOAD ABSORPTION; POWER OUTPUT; PEAK POWER; DERIVATIVES; BODY;
D O I
10.3390/jfmk8010035
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study examined the reliability, potential bias, and practical differences between the GymAware Powertool (GA), Tendo Power Analyzer (TENDO), and Push Band 2.0 (PUSH) during the jump shrug (JS) and hang high pull (HHP) performed across a spectrum of loads. Fifteen resistance-trained men performed JS and HHP repetitions with 20, 40, 60, 80, and 100% of their 1RM hang power clean, and mean (MBV) and peak barbell velocity (PBV) were determined by each velocity measurement device. Least-products regression and Bland-Altman plots were used to examine instances of proportional, fixed, and systematic bias between the TENDO and PUSH compared to the GA. Hedge's g effect sizes were also calculated to determine any meaningful differences between devices. The GA and TENDO displayed excellent reliability and acceptable variability during the JS and HHP while the PUSH showed instances of poor-moderate reliability and unacceptable variability at various loads. While the TENDO and PUSH showed instances of various bias, the TENDO device demonstrated greater validity when compared to the GA. Trivial-small differences were shown between the GA and TENDO during the JS and HHP exercises while trivial-moderate differences existed between GA and PUSH during the JS. However, despite trivial-small effects between the GA and PUSH devices at 20 and 40% 1RM during the HHP, practically meaningful differences existed at 60, 80, and 100%, indicating that the PUSH velocity outputs were not accurate. The TENDO appears to be more reliable and valid than the PUSH when measuring MBV and PBV during the JS and HHP.
引用
收藏
页数:19
相关论文
共 20 条
  • [1] The Reliability, Bias, Differences, and Agreement Between Velocity Measurement Devices During the Hang Clean Pull
    Kissick, Cameron R.
    Techmanski, Baylee S.
    Comfort, Paul
    Suchomel, Timothy J.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2025, 39 (03) : 289 - 294
  • [2] Validity and reliability of simple measurement device to assess the velocity of the barbell during squats
    Lorenzetti S.
    Lamparter T.
    Lüthy F.
    BMC Research Notes, 10 (1) : 707
  • [3] Validity and Reliability of the Inertial Measurement Unit for Barbell Velocity Assessments: A Systematic Review
    Clemente, Filipe Manuel
    Akyildiz, Zeki
    Pino-Ortega, Jose
    Rico-Gonzalez, Markel
    SENSORS, 2021, 21 (07)
  • [4] Concurrent validity and reliability of real time barbell velocity and power measurement in the squat exercise
    Dias, Amandio
    Espada, Mario
    Silva, Eduardo
    Teixeira, Diogo S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2025,
  • [5] Validity and reliability of Gyko Sport for the measurement of barbell velocity on the bench-press exercise
    Arede, Jorge
    Figueira, Bruno
    Gonzalo-Skok, Oliver
    Leite, Nuno
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2019, 59 (10): : 1651 - 1658
  • [6] Validity and reliability of the WIMU® system to measure barbell velocity during the half-squat exercise
    Garcia-Pinillos, Felipe
    Latorre-Roman, Pedro A.
    Valdivieso-Ruano, Fernando
    Balsalobre-Fernandez, Carlos
    Parraga-Montilla, Juan A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2019, 233 (03) : 408 - 415
  • [7] COMPARISON OF THE HANG HIGH PULL AND LOADED JUMP SQUAT FOR THE DEVELOPMENT OF VERTICAL JUMP AND ISOMETRIC FORCE-TIME CHARACTERISTICS
    Oranchuk, Dustin J.
    Robinson, Tracey L.
    Switaj, Zachary J.
    Drinkwater, Eric J.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2019, 33 (01) : 17 - 24
  • [8] Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise
    Balsalobre-Fernandez, Carlos
    Marchante, David
    Munoz-Lopez, Mario
    Jimenez, Sergio L.
    JOURNAL OF SPORTS SCIENCES, 2018, 36 (01) : 64 - 70
  • [9] Reliability of force-velocity relationships during deadlift high pull
    Lu, Wei
    Boyas, Sebastien
    Jubeau, Marc
    Rahmani, Abderrahmane
    SPORTS BIOMECHANICS, 2019, 18 (03) : 277 - 288
  • [10] The Criterion Validity and Between-Day Reliability of the Perch for Measuring Barbell Velocity During Commonly Used Resistance Training Exercises
    Weakley, Jonathon
    Munteanu, Gabriella
    Cowley, Nicholas
    Johnston, Rich
    Morrison, Matthew
    Gardiner, Carissa
    Perez-Castilla, Alejandro
    Garcia-Ramos, Amador
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2023, 37 (04) : 787 - 792