Controlling Wind Pressure Around Buildings: Using Automated Multi-Angle Ventilation Louvers for Higher Natural Ventilation Potential

被引:0
|
作者
Lim, SungHwan [1 ]
Malkawi, Ali [2 ]
Norford, Leslie [3 ]
机构
[1] Harvard Univ, Grad Sch Arts & Sci, Cambridge, MA 02138 USA
[2] Harvard Univ, Architectural Technol, Grad Sch Design, Cambridge, MA USA
[3] MIT, Architecture, Sch Architecture Planning, Cambridge, MA USA
来源
ASHRAE TRANSACTIONS 2023, VOL 129, PT 1 | 2023年 / 129卷
关键词
IMPACT;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Natural ventilation (NV) is an effective means of reducing building energy consumption and enhancing indoor air quality (IAQ) by conveying outdoor air into space. Recently, rising concern about climate change and the COVID-19 aroused interest in raising the potential of NV. However, the uncertainty of airflow around the building, and windows control that rely on the occupant's behavior is a huddle to achieve higher NV potential in conventional buildings. This research proposes an automated multi-angle ventilation louver that can provide a desired and stable airflow into space by controlling the axis position and opening angle, leading to higher NV potential. The louver is designed to open in different directions and angles according to the wind condition to meet the optimized need for cooling and ventilation in the space. The performance of the louver was tested on multiple cases of wind conditions and louver configurations by computational fluid dynamics (CFD) simulations. The airflow data collected from the CFD simulations showed that the louver generates higher NV potential compared to the opening without the louvers. Next, the data was trained by linear regression, and a model was created to predict airflow from various conditions. Based on the model, this research introduces a simulation tool developed in Rhinoceros and Grasshopper. The simulation tool that is linked to the building energy simulation tool can assist designers and engineers in exploring the potential of NV when utilizing the louvers at different locations, building programs, and building configurations. The tool further indicates louver control and coordination on an hourly basis that can achieve maximized NV potential. Overall, this research expands the applicability of NV in both new and existing buildings by introducing an automated multi-angle ventilation louver and facilitating the use of NV for cooling and ventilating the space. Buildings that are in a disadvantageous location for NV in terms of weather conditions or the surrounding environment might also gain feasibility in utilizing NV by the louver. Further study will optimize the louver design and apply model predictive control (MPC) to the control system. Specifically, a mock-up model will be made to validate the increase of potential, and the control system will be able to predict variations in indoor environments and building surrounding conditions in advance and make an optimized decision.
引用
收藏
页码:302 / 310
页数:9
相关论文
共 10 条
  • [1] Impact of Wind Pressure Coefficients on the Natural Ventilation Effectiveness of Buildings through Simulations
    Sakiyama, Nayara Rodrigues Marques
    Carlo, Joyce Correna
    Sakiyama, Felipe Isamu Harger
    Abdessemed, Nadir
    Frick, Jurgen
    Garrecht, Harald
    BUILDINGS, 2024, 14 (09)
  • [2] Use of wind pressure coefficients to simulate natural ventilation and building energy for isolated and surrounded buildings
    Xie, Xiaoxiong
    Luo, Zhiwen
    Grimmond, Sue
    Blunn, Lewis
    BUILDING AND ENVIRONMENT, 2023, 230
  • [3] Influence of placement and height of high-rise buildings on wind pressure distribution and natural ventilation of low- and medium-rise buildings
    Kuznetsov, Sergey
    Butova, Alla
    Pospisil, Stanisla
    INTERNATIONAL JOURNAL OF VENTILATION, 2016, 15 (3-4) : 253 - 266
  • [4] Method of lungs regional ventilation function assessment on the basis of continuous lung monitoring results using multi-angle electrical impedance tomography
    Aleksanyan, Grayr
    Shcherbakov, Ivan
    Kucher, Artem
    Sulyz, Andrew
    INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, MATERIALS AND APPLIED SCIENCE, 2018, 1952
  • [5] Natural ventilation potential of high-rise residential buildings in northern China using coupling thermal and airflow simulations
    Li, Yan
    Li, Xiaofeng
    BUILDING SIMULATION, 2015, 8 (01) : 51 - 64
  • [6] Natural ventilation potential of high-rise residential buildings in northern China using coupling thermal and airflow simulations
    Yan Li
    Xiaofeng Li
    Building Simulation, 2015, 8 : 51 - 64
  • [7] Preliminary design method for naturally ventilated buildings using target air change rate and natural ventilation potential maps in the United States
    Hiyama, Kyosuke
    Glicksman, Leon
    ENERGY, 2015, 89 : 655 - 666
  • [8] Multi-objective optimization of window configuration and furniture arrangement for the natural ventilation of office buildings using Taguchi-based grey relational analysis
    Yin, Xin
    Muhieldeen, Mohammed W.
    Razman, Ruzaimah
    Ee, Jonathan Yong Chung
    ENERGY AND BUILDINGS, 2023, 296
  • [9] Sizing Natural Ventilation Systems for Cooling: The Potential of NV Systems to Deliver Thermal Comfort While Reducing Energy Demands of Multi-Storey Residential Buildings in India
    De Faria, Luciano
    Cook, Malcolm J.
    Loveday, Dennis
    Angelopoulos, Charalampos
    Manu, Sanyogita
    Shukla, Yash
    SMART AND HEALTHY WITHIN THE TWO-DEGREE LIMIT (PLEA 2018), VOL 1, 2018, : 218 - 224
  • [10] A wind tunnel study of natural ventilation for multi-span greenhouse scale models using two-dimensional particle image velocimetry (PIV)
    Lee, I
    Sase, S
    Okushima, L
    Ikeguchi, A
    Choi, K
    Yun, J
    TRANSACTIONS OF THE ASAE, 2003, 46 (03): : 763 - 772