Preanalytical conditions for multiparameter platelet flow cytometry

被引:1
|
作者
Hindle, Matthew S. [1 ,2 ,3 ]
Cheah, Lih T. [1 ]
Yates, Daisie M. [1 ]
Naseem, Khalid M. [1 ]
机构
[1] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Discovery & Translat Sci Dept, Leeds, England
[2] Leeds Beckett Univ, Ctr Biomed Sci Res, Sch Hlth, Leeds, England
[3] Leeds Beckett Univ, Ctr Biomed Sci Res, Sch Hlth, Leeds LS1 3HE, West Yorks, England
关键词
anticoagulants; blood platelets; cytofluorometry; flow; flow cytometry; platelet activation; platelet function tests; PROCOAGULANT PLATELETS; FIBRINOGEN BINDING; WHOLE-BLOOD; P-SELECTIN; ACTIVATION; MARKERS; ANTICOAGULANTS; GUIDELINES; THROMBIN;
D O I
10.1016/j.rpth.2023.102205
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Flow cytometry is an important technique for understanding multiple aspects of blood platelet biology. Despite the widespread use of the platform for assessing platelet function, the optimization and careful consideration of preanalytical conditions, sample processing techniques, and data analysis strategies should be regularly assessed. When set up and designed with optimal conditions, it can ensure the acquisition of robust and reproducible flow cytometry data. However, these parameters are rarely described despite their importance.Objectives: We aimed to characterize the effects of several preanalytical variables on the analysis of blood platelets by multiparameter fluorescent flow cytometry.Methods: We assessed anticoagulant choice, sample material, sample processing, and storage times on 4 distinct and commonly used markers of platelet activation, including fibrinogen binding, expression of CD62P and CD42b, and phosphatidylserine exposure.Results: The use of suboptimal conditions led to increases in basal platelet activity and reduced sensitivities to stimulation; however, the use of optimal conditions protected the platelets from artifactual stimulation and preserved basal activity and sensitivity to activation.Conclusion: The optimal preanalytical conditions identified here for the measurement of platelet phenotype by flow cytometry suggest a framework for future development of multiparameter platelet assays for high-quality data sets and advanced analysis.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Quality control in the preanalytical phase of flow cytometry
    Heins, M
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1996, 23 (02): : 107 - 108
  • [2] Assessment of immunotoxicity by multiparameter flow cytometry
    Burchiel, SW
    Kerkvliet, NL
    Gerberick, GF
    Lawrence, DA
    Ladics, GS
    FUNDAMENTAL AND APPLIED TOXICOLOGY, 1997, 38 (01): : 38 - 54
  • [3] Myelopoiesis in myelodysplasia evaluated by multiparameter flow cytometry
    Jensen, IM
    LEUKEMIA & LYMPHOMA, 1995, 20 (1-2) : 17 - 25
  • [4] Immunophenotypic study of basophils by multiparameter flow cytometry
    Han, Xiaohong
    Jorgensen, Jeffrey L.
    Brahmandam, Archana
    Schlette, Ellen
    Huh, Yang O.
    Shi, Yuankai
    Awagu, Sylvester
    Chen, Weina
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2008, 132 (05) : 813 - 819
  • [5] Multiparameter DNA flow cytometry of human carcinomas
    Corver, Willem E.
    CYTOMETRY PART A, 2007, 71A (09) : 747 - 748
  • [6] Diagnosing PNH with FLAER and multiparameter flow cytometry
    Sutherland, D. Robert
    Kuek, Nancy
    Davidson, Jeff
    Barth, David
    Chang, Hong
    Yeo, Erik
    Bamford, Sylvia
    Chin-Yee, Ian
    Keency, Michael
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2007, 72B (03) : 167 - 177
  • [7] CHARACTERIZATION OF BACTERIA BY MULTIPARAMETER FLOW-CYTOMETRY
    ALLMAN, R
    HANN, AC
    MANCHEE, R
    LLOYD, D
    JOURNAL OF APPLIED BACTERIOLOGY, 1992, 73 (05): : 438 - 444
  • [8] A MULTIPARAMETER FLOW CYTOMETRY METHOD FOR PNH DIAGNOSIS
    Li, Susann
    Jacobsson, Stefan
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2009, 76B (06) : 426 - 427
  • [9] MULTIPARAMETER DNA FLOW-CYTOMETRY OF KERATOACANTHOMA
    SEIDMAN, JD
    BERMAN, JJ
    MOORE, GW
    YETTER, RA
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1992, 14 (02): : 113 - 119
  • [10] MULTIPARAMETER ANALYSIS OF LEUKOCYTES BY FLOW-CYTOMETRY
    STEWART, CC
    STEWART, SJ
    METHODS IN CELL BIOLOGY, VOL 41, 1994, 41 : 61 - 79