Visual Localization of an Internal Inspection Robot for the Oil-Immersed Transformer

被引:0
|
作者
Feng, Yingbin [1 ]
Kou, Yahui [1 ]
Liu, Yanju [1 ]
机构
[1] Shenyang Ligong Univ, Sch Automat & Elect, Shenyang 110159, Liaoning, Peoples R China
关键词
Electric transformer testing - Oil filled transformers - Robot applications;
D O I
10.1155/2023/6699265
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Aiming at the problem that the robot is difficult to locate in the oil-immersed transformer, a visual positioning of the robot is proposed for internal inspection. First, in order to solve the problem of blur, distortion, and low contrast of the image obtained by the camera in the deteriorated and discolored transformer oil, an image enhancement algorithm based on multiscale fusion is developed to provide a reliable data source for robot localization. Then, the FAST key points are extracted and the BRIEF descriptors are calculated from the enhanced images, and the pose transformation of the robot between image frames is calculated by using polar constraint and EPnP method. A pose optimization model of the robot is designed to improve the positioning accuracy. Finally, to verify the effectiveness of the proposed methods, function tests are carried out by using the real continuous image sequence acquired by the robot in Mitsubishi transformer. The experimental results show that the trajectory of the robot in the transformer can be accurately drawn, the position data of the robot can be efficiently obtained, and autonomous positioning of the robot in the transformer can be well achieved.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Design and Analysis of Oil-Immersed Transformer Internal Detection Robot
    Li Xun
    Huang Ronghui
    Wang Yabiao
    He Zhen
    Li Zhigang
    [J]. 2017 2ND ASIA-PACIFIC CONFERENCE ON INTELLIGENT ROBOT SYSTEMS (ACIRS), 2017, : 264 - 269
  • [2] Depth hover control of spherical robot for internal detection of oil-immersed transformer
    Feng, Ying-Bin
    Zhao, Xiao-Hu
    He, Zhen
    Li, Zhi-Gang
    Wang, Ya-Biao
    [J]. Kongzhi yu Juece/Control and Decision, 2020, 35 (02): : 375 - 381
  • [3] Study on Fault Detection Robot for Oil-immersed Transformer based on WiFi control
    Huang, Ronghui
    Zhao, Yuming
    Li, Xun
    Feng, Yingbin
    Wu, Guoxing
    Li, Zhigang
    [J]. 2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 50 - 55
  • [4] Experimental and Numerical Investigation of the Internal Temperature of an Oil-Immersed Power Transformer with DOFS
    Liu, Yunpeng
    Li, Xinye
    Li, Huan
    Wang, Jiaxue
    Fan, Xiaozhou
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (16):
  • [5] Lifespan estimation of oil-immersed electric transformer
    Endo, T
    Nagamoto, H
    O'Shima, E
    [J]. KAGAKU KOGAKU RONBUNSHU, 2004, 30 (05) : 710 - 714
  • [6] Application of Dielectric Response for Oil-immersed Transformer
    Yang, Shuangsuo
    Dong, Ming
    Zhang, Guanjun
    Zhang, Zhi
    [J]. ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 370 - +
  • [7] Transient Moisture Equilibrium in Oil-immersed Transformer
    Zhou, Lijun
    Wu, Guangning
    Liu, Jun
    Ma, Guo
    Lv, Wei
    Wang, Tao
    Gao, Zhongbao
    [J]. ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 165 - 167
  • [8] Recovery Voltage Measurements of Oil-immersed Transformer
    Li, Ming-hua
    Dong, Ming
    Qu, Yan-ming
    Yan, Zhang
    [J]. TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2006, 7 (05) : 230 - 234
  • [9] Generation and prevention of latent oil leak in oil-immersed transformer
    Chen, Xinhui
    Zhou, Wenjie
    [J]. Bianyaqi/Transformer, 2000, 37 (02): : 23 - 25
  • [10] Study on the deformation of the oil-immersed transformer tank by FEA
    Zhang, Jianhua
    Sun, Lingyu
    Zhang, Xiaojun
    Li, Jiapeng
    [J]. EQUIPMENT MANUFACTURING TECHNOLOGY, 2012, 422 : 51 - +